Total-body dynamic PET/CT imaging reveals kinetic distribution of [13N]NH3 in normal organs
European Journal of Nuclear Medicine and Molecular Imaging · 2024
DOI: 10.1007/s00259-024-06826-3 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Nuclear Medicine and Molecular Imaging, 2024. Verfasst von Guobing Liu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, No. 180 in Fenglin Road, Shanghai, 200032, P.R. China. Hauptthemen laut MEDLINE: Positron Emission Tomography Computed Tomography. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 41 Literaturangaben. Gefördert von: Innovative Medical Device Application Demonstration Program of Shanghai Municipal Commission of Economy and Informatization, Chinese National Key Clinical Specialty Program, National Key Research and Development Program of China.
Abstract (Originalsprache)
PURPOSE: To systematically investigate kinetic metrics and metabolic trapping of [13N]NH3 in organs. METHODS: Eleven participants performed total-body [13N]NH3 dynamic positron emission tomography (PET). Regions of interest were drawn in organs to obtain time-to-activity curves (TACs), which were fitted with an irreversible two-tissue compartment model (2TC) to investigate constant rates K1, k2 and k3, and to calculate Ki. Additionally, one-tissue compartment model using full data (1TCfull) and the first four minutes of data (1TC4min) were fitted to TAC data. K1 and k2 were compared among different models to assess [13N]NH3 trapping in organs. RESULTS: Kinetic rates of [13N]NH3 varied significantly among organs. The mean K1 ranged from 0.049 mL/cm3/min in the muscle to 2.936 mL/cm3/min in the kidney. The k2 and k3 were lowest in the liver (0.001 min- 1) and in the pituitary (0.009 min- 1), while highest in the kidney (0.587 min- 1) and in the liver (0.800 min- 1), respectively. The Ki was largest in the myocardium (0.601 ± 0.259 mL/cm3/min) while smallest in the bone marrow (0.028 ± 0.022 mL/cm3/min). Three groups of organs with similar kinetic characteristics were revealed: (1) the thyroid, the lung, the spleen, the pancreas, and the kidney; (2) the liver and the muscle; and (3) the cortex, the white matter, the cerebellum, the pituitary, the parotid, the submandibular gland, the myocardium, the bone, and the bone marrow. Obvious k3 was identified in multiple organs, and significant changes of K1 in multiple organs and k2 in most organs were found between 2TC and 1TCfull, but both K1 and k2 were comparable between 2TC and 1TC4min. CONCLUSION: The kinetic rates of [13N]NH3 differed among organs with some have obvious 13N-anmmonia trapping. The normal distribution of kinetic metrics of 13N-anmmonia in organs can serve as a reference for its potential use in tumor imaging.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, No. 180 in Fenglin Road, Shanghai, 200032, P.R. China.
- Institute of Nuclear Medicine, Fudan University, Shanghai, China.
- Shanghai Institute of Medical Imaging, Shanghai, China.
- Cancer Prevention and Treatment Center, Zhongshan Hospital, Fudan University, Shanghai, China.
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, No. 180 in Fenglin Road, Shanghai, 200032, P.R. China. shi.hongcheng@zs-hospital.sh.cn.
- Institute of Nuclear Medicine, Fudan University, Shanghai, China. shi.hongcheng@zs-hospital.sh.cn.
ORCID-Profile: Hongcheng Shi
Förderung
- Innovative Medical Device Application Demonstration Program of Shanghai Municipal Commission of Economy and Informatization
- Chinese National Key Clinical Specialty Program
- National Key Research and Development Program of China
Zitieren
APA
Liu, G., Gu, T., Chen, S., Gu, Y., Yu, H., & Shi, H. (2024). Total-body dynamic PET/CT imaging reveals kinetic distribution of [13N]NH3 in normal organs. European Journal of Nuclear Medicine and Molecular Imaging. https://doi.org/10.1007/s00259-024-06826-3
Vancouver
Liu G, Gu T, Chen S, Gu Y, Yu H, Shi H. Total-body dynamic PET/CT imaging reveals kinetic distribution of [13N]NH3 in normal organs. European Journal of Nuclear Medicine and Molecular Imaging. 2024. doi:10.1007/s00259-024-06826-3
BibTeX
@article{Liu2024,
author = {Liu, Guobing and Gu, Taoying and Chen, Shuguang and Gu, Yushen and Yu, Haojun and Shi, Hongcheng},
title = {Total-body dynamic PET/CT imaging reveals kinetic distribution of [13N]NH3 in normal organs},
journal = {European Journal of Nuclear Medicine and Molecular Imaging},
year = {2024},
doi = {10.1007/s00259-024-06826-3}
}
EUVIMED