Fachartikel in der Zeitschrift European Journal of Nuclear Medicine and Molecular Imaging, 2023. Verfasst von David J Liesker und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery (Division of Vascular Surgery), University Medical Center Groningen, University of Groningen, PO Box 30.001, 9700 RB, Groningen…. Hauptthemen laut MEDLINE: Positron Emission Tomography Computed Tomography, Vascular Diseases. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
18 F-fluoro-D-deoxyglucose positron emission tomography with low dose and/or contrast enhanced computed tomography ([ 18 F]FDG-PET/CT) scan reveals high sensitivity for the diagnosis of vascular graft and endograft infection (VGEI), but lower specificity. Reporting [ 18 F]FDG-PET/CT scans of suspected VGEI is challenging, reader dependent, and reporting standards are lacking. The aim of this study was to evaluate variability of [ 18 F]FDG-PET/low dose CT (LDCT) reporting of suspected VGEI using a proposed standard reporting format.
Methods
A retrospective cohort study was conducted including all patients with a suspected VGEI (according to the MAGIC criteria) without need for urgent surgical treatment who underwent an additional [ 18 F]FDG-PET/LDCT scan between 2006 and 2022 at a tertiary referral centre. All [ 18 F]FDG-PET/LDCT reports were scored following pre-selected criteria that were formulated based on literature and experts in the field. The aim was to investigate the completeness of [ 18 F]FDG-PET/LDCT reports for diagnosing VGEI (proven according to the MAGIC criteria) and to evaluate if incompleteness of reports influenced the diagnostic accuracy.
Results
Hundred-fifty-two patients were included. Median diagnostic interval from the index vascular surgical procedure until [ 18 F]FDG-PET/LDCT scan was 35.5 (7.3–73.3) months. Grafts were in 65.1% located centrally and 34.9% peripherally. Based on the pre-selected reporting criteria, 45.7% of the reports included all items. The least frequently assessed criterion was FDG-uptake pattern (40.6%). Overall, [ 18 F]FDG-PET/LDCT showed a sensitivity of 91%, a specificity of 72%, and an accuracy of 88% when compared to the gold standard (diagnosed VGEI). Lower sensitivity and specificity in reports including ≤ 8 criteria compared to completely evaluated reports were found (83% and 50% vs. 92% and 77%, respectively).
Conclusion
Less than half of the [ 18 F]FDG-PET/LDCT reports of suspected VGEI met all pre-selected criteria. Incompleteness of reports led to lower sensitivity and specificity. Implementing a recommendation with specific criteria for VGEI reporting is needed in the VGEI-guideline update. This study provides a first recommendation for a concise and complete [ 18 F]FDG-PET/LDCT report in patients with suspected VGEI.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Surgery (Division of Vascular Surgery), University Medical Center Groningen, University of Groningen, PO Box 30.001, 9700 RB, Groningen, The Netherlands. d.j.liesker@umcg.nl.
- Department of Surgery (Division of Vascular Surgery), University Medical Center Groningen, University of Groningen, PO Box 30.001, 9700 RB, Groningen, The Netherlands.
- Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, University of Groningen, PO Box 30.001, 9700 RB, Groningen, The Netherlands.
- Department of Nuclear Medicine, Papa Giovanni XXIII Hospital, Bergamo, Italy.
- Department of Vascular Surgery and Kidney Transplantation, Hôpitaux Universitaires de Strasbourg, Université de Strasbourg, Strasbourg, France.
- Department of Biomedical Photonic Imaging, University of Twente, Enschede, The Netherlands.
ORCID-Profile: David J Liesker
Zitieren
APA
Liesker, D. J., Legtenberg, S., Erba, P. A., Glaudemans, A. W. J. M., Zeebregts, C. J., De Vries, J. P. M., Chakfé, N., Saleem, B. R., & Slart, R. H. J. A. (2023). Variability of [18F]FDG-PET/LDCT reporting in vascular graft and endograft infection. European Journal of Nuclear Medicine and Molecular Imaging. https://doi.org/10.1007/s00259-023-06349-3
Vancouver
Liesker DJ, Legtenberg S, Erba PA, Glaudemans AWJM, Zeebregts CJ, De Vries JPM, et al. Variability of [18F]FDG-PET/LDCT reporting in vascular graft and endograft infection. European Journal of Nuclear Medicine and Molecular Imaging. 2023. doi:10.1007/s00259-023-06349-3
BibTeX
@article{Liesker2023,
author = {Liesker, David J and Legtenberg, Stijn and Erba, Paola A and Glaudemans, Andor W J M and Zeebregts, Clark J and De Vries, Jean-Paul P M and Chakfé, Nabil and Saleem, Ben R and Slart, Riemer H J A},
title = {Variability of [18F]FDG-PET/LDCT reporting in vascular graft and endograft infection},
journal = {European Journal of Nuclear Medicine and Molecular Imaging},
year = {2023},
doi = {10.1007/s00259-023-06349-3}
}
EUVIMED