Voxel-based dosimetry predicting treatment response and related toxicity in HCC patients treated with resin-based Y90 radioembolization: a prospective, single-arm study
European Journal of Nuclear Medicine and Molecular Imaging · 2023
DOI: 10.1007/s00259-023-06111-9 ↗Kurz gefasst
Klinische Studie in der Zeitschrift European Journal of Nuclear Medicine and Molecular Imaging, 2023. Verfasst von Nima Kokabi und 11 weiteren Autor:innen. Beteiligte Einrichtung: Division of Interventional Radiology and Image-Guided Medicine, Department of Radiology and Imaging Sciences, Emory University School of Medicine, At…. Hauptthemen laut MEDLINE: Carcinoma, Hepatocellular, Embolization, Therapeutic, Liver Neoplasms. Die Arbeit wurde bisher 51-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCI NIH HHS, Radiological Society of North America, Sirtex Medical Ltd.
Abstract (Originalsprache)
Background
There is an increasing body of evidence indicating Y90 dose thresholds for tumor response and treatment-related toxicity. These thresholds are poorly studied in resin Y90, particularly in hepatocellular carcinoma (HCC).
Purpose
To evaluate the efficacy of prospective voxel-based dosimetry for predicting treatment response and adverse events (AEs) in patients with HCC undergoing resin-based Y90 radioembolization. Materials and methods This correlative study was based on a prospective single-arm clinical trial (NCT04172714), which evaluated the efficacy of low/scout (555 MBq) activity of resin-based Y90 for treatment planning. Partition model was used with goal of tumor dose (TD) > 200 Gy and non-tumoral liver dose (NTLD) < 70 Gy for non-segmental therapies. Single compartment dose of 200 Gy was used for segmentectomies. Prescribed Y90 activity minus scout activity was administered for therapeutic Y90 followed by Y90-PET/CT. Sureplan® (MIM Software, Cleveland, OH) was used for dosimetry analysis. Treatment response was evaluated at 3 and 6 months. Receiver operating characteristic curve determined TD response threshold for objective response (OR) and complete response (CR) as well as non-tumor liver dose (NTLD) threshold that predicted AEs.
Results
N = 30 patients were treated with 33 tumors (19 segmental and 14 non-segmental). One patient died before the first imaging, and clinical follow-up was excluded from this analysis. Overall, 26 (81%) of the tumors had an OR and 23 (72%) had a CR. A mean TD of 253 Gy predicted an OR with 92% sensitivity and 83% specificity (area under the curve (AUC = 0.929, p < 0.001). A mean TD of 337 Gy predicted a CR with 83% sensitivity and 89% specificity (AUC = 0.845, p < 0.001). A mean NTLD of 81 and 87 Gy predicted grade 3 AEs with 100% sensitivity and 100% specificity in the non-segmental cohort at 3- and 6-month post Y90, respectively.
Conclusion
In patients with HCC undergoing resin-based Y90, there are dose response and dose toxicity thresholds directly affecting outcomes. Clinical trial number: NCT04172714.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Division of Interventional Radiology and Image-Guided Medicine, Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, USA. nkokabi@emory.edu.
- Division of Interventional Radiology, Department of Radiology, Mount Sinai School of Medicine, New York, NY, USA.
- Division of Interventional Radiology, Department of Radiology, University of Texas at San Antonio, San Antonio, TX, USA.
- Division of Nuclear Medicine and Molecular Imaging, Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, USA.
- Division of Abdominal Imaging, Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, USA.
- Division of Interventional Radiology, Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
ORCID-Profile: Nima Kokabi
Förderung
- NCI NIH HHS
- Radiological Society of North America
- Sirtex Medical Ltd
Zitieren
APA
Kokabi, N., Arndt-Webster, L., Chen, B., Brandon, D., Sethi, I., Davarpanahfakhr, A., Galt, J., Elsayed, M., Bercu, Z., Cristescu, M., Kappadath, S. C., & Schuster, D. M. (2023). Voxel-based dosimetry predicting treatment response and related toxicity in HCC patients treated with resin-based Y90 radioembolization: a prospective, single-arm study. European Journal of Nuclear Medicine and Molecular Imaging. https://doi.org/10.1007/s00259-023-06111-9
Vancouver
Kokabi N, Arndt-Webster L, Chen B, Brandon D, Sethi I, Davarpanahfakhr A, et al. Voxel-based dosimetry predicting treatment response and related toxicity in HCC patients treated with resin-based Y90 radioembolization: a prospective, single-arm study. European Journal of Nuclear Medicine and Molecular Imaging. 2023. doi:10.1007/s00259-023-06111-9
BibTeX
@article{Kokabi2023,
author = {Kokabi, Nima and Arndt-Webster, Linzi and Chen, Bernard and Brandon, David and Sethi, Ila and Davarpanahfakhr, Amir and Galt, James and Elsayed, Mohammad and Bercu, Zachary and Cristescu, Mircea and Kappadath, S Cheenu and Schuster, David M},
title = {Voxel-based dosimetry predicting treatment response and related toxicity in HCC patients treated with resin-based Y90 radioembolization: a prospective, single-arm study},
journal = {European Journal of Nuclear Medicine and Molecular Imaging},
year = {2023},
doi = {10.1007/s00259-023-06111-9}
}