Clinical outcomes and safety reporting after image-guided and non-image-guided subtalar joint injections: a systematic review
Skeletal Radiology · 12.11.2026
DOI: 10.1007/s00256-026-05422-w ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Skeletal Radiology, online erschienen am 12.11.2026. Verfasst von Jonathan Gibson und 6 weiteren Autor:innen. Beteiligte Einrichtung: College of Medical and Dental Sciences, University of Birmingham, Birmingham, UK. Die Arbeit nennt 36 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Subtalar joint (STJ) injections are used for chronic hindfoot pain but evidence comparing guidance methods remains limited. METHODS: This systematic review followed PRISMA 2020. PubMed, Embase (via Ovid), Scopus and Web of Science were searched from inception to December 2025, and the searches were re-run in a broadened form in July 2026. Eligible studies included comparative studies, single-arm cohort or case-series studies with 10 or more procedures and technical/cadaveric accuracy studies reporting subtalar-specific outcomes. Two reviewers independently screened studies, extracted data and assessed risk of bias. Heterogeneity and scarce direct comparison precluded meta-analysis. RESULTS: Seventeen studies were eligible: 12 reported clinical data and five reported cadaveric technical accuracy data only (one clinical study also contributed a cadaveric control arm). Denominators are reported in their own units and are not combined: the clinical studies contributed 129 patients (six studies), 100 injected joints (four studies) and 779 injections (two studies). Ultrasound, fluoroscopy and landmark-guided injection were each reported in five studies. No study of CT or SPECT-CT guidance provided a subtalar-specific outcome. Needle placement accuracy ranged from 68 to 100%, but difference in design, populations and confirmation methods prevented comparison between modalities. CONCLUSION: STJ injections are associated with clinical improvement but evidence is predominantly observational and heterogeneous. Differences in reporting technical accuracy, injectate, clinical response and adverse events prevent comparison of guidance methods. No modality's superiority is established. Prospective comparative studies using standardised outcomes and consistent safety reporting are needed.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- College of Medical and Dental Sciences, University of Birmingham, Birmingham, UK.
- South Warwickshire University NHS Foundation Trust, South Warwickshire, UK.
- Glasgow Royal Infirmary, Glasgow, UK.
- Department of Diagnostic and Interventional Radiology, All India Institute of Medical Sciences, Dehradun, Uttarakhand, India.
- Department of Orthopaedics, University Hospitals Birmingham NHS Foundation Trust, Birmingham, UK.
- Department of Musculoskeletal Radiology, Royal Orthopaedic Hospital, Birmingham, UK. drbrajesh@yahoo.com.
Zitieren
APA
Gibson, J., Agrawal, N., Maleyko, I., Thompson, B., Saran, S., Labidi, M., & Botchu, R. (2026). Clinical outcomes and safety reporting after image-guided and non-image-guided subtalar joint injections: a systematic review. Skeletal Radiology. https://doi.org/10.1007/s00256-026-05422-w
Vancouver
Gibson J, Agrawal N, Maleyko I, Thompson B, Saran S, Labidi M, et al. Clinical outcomes and safety reporting after image-guided and non-image-guided subtalar joint injections: a systematic review. Skeletal Radiology. 2026. doi:10.1007/s00256-026-05422-w
BibTeX
@article{Gibson2026,
author = {Gibson, Jonathan and Agrawal, Nidhi and Maleyko, Igor and Thompson, Ben and Saran, Sonal and Labidi, May and Botchu, Rajesh},
title = {Clinical outcomes and safety reporting after image-guided and non-image-guided subtalar joint injections: a systematic review},
journal = {Skeletal Radiology},
year = {2026},
doi = {10.1007/s00256-026-05422-w}
}