Diagnostic performance and reproducibility of standardized two-plane ultrasound cine clips for supraspinatus tendon pathology
Skeletal Radiology · 31.10.2026
DOI: 10.1007/s00256-026-05415-9 ↗Kurz gefasst
Fachartikel in der Zeitschrift Skeletal Radiology, online erschienen am 31.10.2026. Verfasst von Sono Khan und 4 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Medicine, University of Ottawa, Ottawa, ON, Canada. Die Arbeit nennt 24 Literaturangaben.
Abstract (Originalsprache)
Objective
To determine the diagnostic performance and reader reproducibility of standardized two-plane cine clips for supraspinatus tendon pathology, using the complete radiologist-supervised shoulder ultrasound examination as the clinical reference standard. Materials and methods This prospective single-centre study screened 140 consecutive shoulder ultrasound examinations. Standardized longitudinal and transverse supraspinatus cine clips were independently reviewed by two fellowship-trained musculoskeletal radiologists blinded to the clinical report. Reader 1 read all included examinations (24 twice); Reader 2 read 51. Diagnostic performance (exact 95% confidence intervals) was calculated against the same-day clinical ultrasound report, and reliability with Cohen’s κ. Reporting radiologists could access the standardized clips.
Results
Of 140 examinations, 114 were analyzed (mean age 57 years; 56 women). Reader 1 showed high performance for full-thickness tears (sensitivity 87% [95% confidence interval 69–96%], specificity 98% [92–100%]) and complete tears (sensitivity 73% [39–94%], specificity 97% [92–99%]). Calcific tendinopathy yielded sensitivity/specificity of 79%/85%; partial-thickness tears, 57%/87%; and tendinopathy, 92%/28%. Reader 2 sensitivity was 92% [64–100%] for full-thickness and 18% [2–52%] for partial-thickness tears. Intra-observer κ ranged from 0.17 (tendinopathy) to 0.89 (full-thickness tears). Inter-observer κ was 0.95 for full-thickness, 0.56 for complete and 0.21 for partial-thickness tears.
Conclusion
Standardized two-plane cine clips demonstrate high diagnostic performance and inter-observer reliability for full-thickness supraspinatus tears. For complete tears, inter-observer agreement was moderate and sensitivity was imprecise. Given limited sensitivity for partial-thickness tears and low specificity for tendinopathy, cine clips alone are insufficient for these pathologies and should complement rather than replace complete real-time shoulder ultrasound examinations.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculty of Medicine, University of Ottawa, Ottawa, ON, Canada.
- Department of Radiology, University of British Columbia, Vancouver General Hospital, Vancouver, BC, Canada.
- Department of Radiology, Radiation Oncology and Medical Physics, University of Ottawa, 501 Smyth Road, Ottawa, ON, K1H 8L6, Canada.
- Department of Radiology, Radiation Oncology and Medical Physics, University of Ottawa, 501 Smyth Road, Ottawa, ON, K1H 8L6, Canada. msampaio@toh.ca.
- The Ottawa Hospital Research Institute, Ottawa, ON, Canada. msampaio@toh.ca.
Zitieren
APA
Khan, S., Lee, J., Jibri, Z., de Oliveira Cyrineu, F., & Sampaio, M. L. (2026). Diagnostic performance and reproducibility of standardized two-plane ultrasound cine clips for supraspinatus tendon pathology. Skeletal Radiology. https://doi.org/10.1007/s00256-026-05415-9
Vancouver
Khan S, Lee J, Jibri Z, de Oliveira Cyrineu F, Sampaio ML. Diagnostic performance and reproducibility of standardized two-plane ultrasound cine clips for supraspinatus tendon pathology. Skeletal Radiology. 2026. doi:10.1007/s00256-026-05415-9
BibTeX
@article{Khan2026,
author = {Khan, Sono and Lee, Juvel and Jibri, Zaid and de Oliveira Cyrineu, Fabricio and Sampaio, Marcos Loreto},
title = {Diagnostic performance and reproducibility of standardized two-plane ultrasound cine clips for supraspinatus tendon pathology},
journal = {Skeletal Radiology},
year = {2026},
doi = {10.1007/s00256-026-05415-9}
}
EUVIMED