Evaluating artificial intelligence in the diagnosis of hip fractures: an analysis of sensitivity, specificity, positive and negative predictive values, and accuracy
Bewertung von künstlicher Intelligenz in der Diagnostik von Hüftfrakturen: Analyse von Sensitivität, Spezifität, positivem und negativem prädiktivem Wert sowie Genauigkeit
Skeletal Radiology · 14.09.2026
DOI: 10.1007/s00256-026-05370-5 ↗Auf einen Blick
Milvue SmartUrgences zeigte in einer Notaufnahme-Kohorte eine hohe Sensitivität und einen hohen negativen prädiktiven Wert für Hüftfrakturen auf Röntgenbildern.
Fragestellung
Wie gut erkennt die KI-Software Milvue SmartUrgences Hüftfrakturen auf Röntgenaufnahmen aus der Notaufnahme?
Methode
Retrospektive diagnostische Genauigkeitsstudie bei Patient:innen ≥ 60 Jahre an 2 Notaufnahmen; Referenzstandard durch Expert:innenkonsens. Auswertung von YES/NO separat von DOUBT.
Ergebnisse
539 Patient:innen; 487 mit definitiver KI-Klassifikation in der Hauptanalyse. 191 Hüftfrakturen. Sensitivität 97,4 % (95 %-KI 94,0–98,9), Spezifität 86,5 % (95 %-KI 82,1–89,9), PPV 82,3 %, NPV 98,1 % (95 %-KI 95,6–99,2), Genauigkeit 90,8 % (95 %-KI 87,9–93,0), F1-Score 89,2 %.
Schlussfolgerung der Autor:innen
Milvue SmartUrgences zeigte eine hohe Sensitivität und einen hohen negativen prädiktiven Wert zur Erkennung von Hüftfrakturen. Die Software kann die Akutbeurteilung unterstützen, soll die klinische und radiologische Beurteilung aber nicht ersetzen.
Kernaussagen
- Hüftfrakturen: Sensitivität 97,4 %
- NPV 98,1 %; Genauigkeit 90,8 %
- KI-Output als Ergänzung, nicht als Ersatz der Beurteilung
Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.
Kurz gefasst
Fachartikel in der Zeitschrift Skeletal Radiology, online erschienen am 14.09.2026. Verfasst von Mads Hoelgaard Christensen und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, Aalborg University Hospital, Hobrovej 18-20, 9000, Aalborg, Denmark. Hauptthemen laut MEDLINE: Artificial Intelligence, Hip Fractures, Radiographic Image Interpretation, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Aalborg University Hospital.
Abstract (Originalsprache)
Objectives
To evaluate the diagnostic performance of Milvue SmartUrgences AI software for detecting hip fractures on radiographs obtained in the emergency department (ED).
Methods
This retrospective diagnostic accuracy study included consecutive patients aged ≥ 60 years undergoing hip and pelvis radiography at two EDs between June 2023 and September 2024. The index test was Milvue SmartUrgences, which classified radiographs as “YES,” “NO,” or “DOUBT.” The reference standard was established by a consensus panel of three musculoskeletal radiologists and two senior orthopaedic trauma surgeons, blinded to AI output. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy, and F1-score were calculated. The primary analysis included patients with definitive “YES” or “NO” classifications; “DOUBT” classifications were evaluated separately.
Results
Among 539 included patients, 487 received definitive AI classifications and were included in the primary analysis. The mean age was 83.4 years (SD 8.4), and 66% were female. The reference standard identified 191 hip fractures. Sensitivity was 97.4% (95% CI 94.0–98.9), and specificity was 86.5% (95% CI 82.1–89.9). PPV was 82.3% (95% CI 76.8–86.7), NPV 98.1% (95% CI 95.6–99.2), and accuracy 90.8% (95% CI 87.9–93.0). The F1-score was 89.2%.
Conclusions
Milvue SmartUrgences demonstrated high sensitivity and negative predictive value for hip fracture detection in a consecutive emergency department cohort. The software may provide useful decision support during acute radiographic assessment, but AI output should complement rather than replace clinical and radiological assessment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedics, Aalborg University Hospital, Hobrovej 18-20, 9000, Aalborg, Denmark.
- Department of Radiology, Aalborg University Hospital, Hobrovej 18-20, 9000, Aalborg, Denmark.
- Department of Orthopaedics, Aalborg University Hospital, Hobrovej 18-20, 9000, Aalborg, Denmark. peter.larsen@rn.dk.
- Department of Occupational and Physiotherapy, Aalborg University Hospital, Hobrovej 18-20, 9000, Aalborg, Denmark. peter.larsen@rn.dk.
Förderung
- Aalborg University Hospital
Zitieren
APA
Christensen, M. H., Elsoe, R., Mahdi, F., Hever, M., Arif-Miscov, S., & Larsen, P. (2026). Evaluating artificial intelligence in the diagnosis of hip fractures: an analysis of sensitivity, specificity, positive and negative predictive values, and accuracy. Skeletal Radiology. https://doi.org/10.1007/s00256-026-05370-5
Vancouver
Christensen MH, Elsoe R, Mahdi F, Hever M, Arif-Miscov S, Larsen P. Evaluating artificial intelligence in the diagnosis of hip fractures: an analysis of sensitivity, specificity, positive and negative predictive values, and accuracy. Skeletal Radiology. 2026. doi:10.1007/s00256-026-05370-5
BibTeX
@article{Christensen2026,
author = {Christensen, Mads Hoelgaard and Elsoe, Rasmus and Mahdi, Firaz and Hever, Mate and Arif-Miscov, Sara and Larsen, Peter},
title = {Evaluating artificial intelligence in the diagnosis of hip fractures: an analysis of sensitivity, specificity, positive and negative predictive values, and accuracy},
journal = {Skeletal Radiology},
year = {2026},
doi = {10.1007/s00256-026-05370-5}
}
EUVIMED