Diagnostic accuracy of 3D MRI rendering techniques for evaluation of hourglass-like constrictions in Parsonage-Turner syndrome
Skeletal Radiology · 06.11.2026
DOI: 10.1007/s00256-026-05367-0 ↗Kurz gefasst
Fachartikel in der Zeitschrift Skeletal Radiology, online erschienen am 06.11.2026. Verfasst von Delaram Shakoor und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Imaging, Hospital for Special Surgery, 535 E 70 St, New York, NY, 10021, USA. shakoord@hss.edu. Die Arbeit nennt 29 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVE: To evaluate inter-reader agreement and diagnostic accuracy of curved multiplanar reformatting (cMPR) and maximum intensity projection (MIP) techniques for detecting hourglass-like constrictions (HGCs). MATERIALS AND METHODS: Thirty brachial plexus 3-Tesla, 3D, 1-mm isotropic MR neurography (MRN) datasets (10 patients without and 20 patients with Parsonage-Turner syndrome (PTS) affecting the suprascapular nerve (SSN)) were retrospectively analyzed by four musculoskeletal radiology fellows for the number and severity of HGCs using both post-processing views in a randomized, blinded fashion. An experienced, attending radiologist served as the reference standard. Inter-reader agreement was assessed using Gwet's AC1 and intraclass correlation (ICC). Image interpretation time was compared using Wilcoxon signed-rank test. RESULTS: Inter-reader agreement for HGC presence was substantial to almost perfect among fellows (cMPR AC1 = 0.7, MIP AC1 = 0.67) and when compared to the attending (cMPR AC1 = 0.67-0.83, MIP AC1 = 0.63-0.83). Agreement for severe HGC count was substantial to almost perfect (fellows: cMPR ICC = 0.65, MIP ICC = 0.79; vs. attending: ICC = 0.62-0.83, MIP ICC = 0.69-0.88), but poor to fair for mild HGCs (fellows: cMPR ICC = 0.23, MIP ICC = 0.26; vs. attending: ICC = 0-0.21, MIP ICC = 0-0.09). Sensitivity to HGC presence was excellent (cMPR, 85-100%; MIP, 90-100%), though specificity (cMPR, 50-100%; MIP, 40-90%) and diagnostic accuracy (cMPR, 80-90%; MIP, 76-90%) varied. The MIP method required significantly less interpretation time than cMPR (median: 33 vs. 104 s, p < 0.001). CONCLUSION: High inter-reader agreement and sensitivity but variable specificity for HGC detection suggest both techniques are viable tools for MRN, with cMPR better suited for detailed HGC evaluation and MIP for initial screening.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology and Imaging, Hospital for Special Surgery, 535 E 70 St, New York, NY, 10021, USA. shakoord@hss.edu.
- Department of Radiology and Imaging, Hospital for Special Surgery, 535 E 70 St, New York, NY, 10021, USA.
- Department of Biostatistics, Hospital for Special Surgery, New York, NY, USA.
Zitieren
APA
Shakoor, D., McKinney, E. J., Queler, S. C., Davis-Hayes, C., Hao, M., Baker, A., Wang, S. H., Tan, E. T., & Sneag, D. B. (2026). Diagnostic accuracy of 3D MRI rendering techniques for evaluation of hourglass-like constrictions in Parsonage-Turner syndrome. Skeletal Radiology. https://doi.org/10.1007/s00256-026-05367-0
Vancouver
Shakoor D, McKinney EJ, Queler SC, Davis-Hayes C, Hao M, Baker A, et al. Diagnostic accuracy of 3D MRI rendering techniques for evaluation of hourglass-like constrictions in Parsonage-Turner syndrome. Skeletal Radiology. 2026. doi:10.1007/s00256-026-05367-0
BibTeX
@article{Shakoor2026,
author = {Shakoor, Delaram and McKinney, Emma J and Queler, Sophie C and Davis-Hayes, Cecilia and Hao, Max and Baker, Adam and Wang, Shu-Han and Tan, Ek T and Sneag, Darryl B},
title = {Diagnostic accuracy of 3D MRI rendering techniques for evaluation of hourglass-like constrictions in Parsonage-Turner syndrome},
journal = {Skeletal Radiology},
year = {2026},
doi = {10.1007/s00256-026-05367-0}
}
EUVIMED