Fachartikel in der Zeitschrift Skeletal Radiology, online erschienen am 05.08.2026. Verfasst von Kyu-Chong Lee und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Korea University Anam Hospital, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Portable X-Ray, Leg Length Inequality. Die Arbeit nennt 19 Literaturangaben. Gefördert von: Ministry of Health & Welfare, Republic of Korea.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: To evaluate the clinical feasibility of a camera-type X-ray system, compared with conventional portable X-ray, for intraoperative imaging during hip arthroplasty. MATERIALS AND METHODS: Twenty-one patients who underwent hip arthroplasty were prospectively enrolled. Conventional portable and camera-type X-ray images were obtained intraoperatively (n = 42). Three reviewers (two radiologists and one orthopedic surgeon) independently assessed image quality and diagnostic confidence using 4-point Likert scales, as well as the feasibility of assessing leg length discrepancies (LLD), calculated as the difference between the transischial line and the lesser trochanter (TI-LT). Two radiologists also measured the TI-LT interval in both modalities. Image quality and diagnostic confidence were compared using the Wilcoxon rank-sum test. The feasibility of LLD assessment was analyzed using Fisher's exact test. The agreement between camera-type and portable X-ray measurements was evaluated using intraclass correlation coefficients (ICCs). RESULTS: Image quality scores were significantly higher for portable X-rays than for camera-type X-rays (mean ± SD, 3.65 ± 0.44 vs. 2.57 ± 0.89; p 0.1). The TI-LT interval measurements demonstrated good agreement between camera-type and portable X-rays, with an ICC of 0.750 (95% CI 0.454-0.898). CONCLUSIONS: Although conventional portable X-rays provided superior image quality and diagnostic confidence, camera-type X-rays demonstrated comparable feasibility for intraoperative evaluation of LLD and good agreement in quantitative measurements. These findings support the clinical feasibility of using camera-type X-rays for intraoperative imaging during hip arthroplasty.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipPortable X-RayLeg Length InequalityHumansFeasibility StudiesPilot ProjectsFemaleProspective StudiesMaleAgedMiddle AgedReproducibility of ResultsIntraoperative Care

Stichwörter der Autor:innen

Camera-type X-rayHip arthroplastyImage qualityLeg length discrepancyPortable X-ray

Autor:innen und Institutionen

  • Department of Radiology, Korea University Anam Hospital, Seoul, Republic of Korea.
  • Department of Radiology and Advanced Medical Imaging Institute, Korea University Anam Hospital, Korea University College of Medicine, Seoul, Republic of Korea.
  • Department of Orthopedic Surgery, Korea University Anam Hospital, Seoul, Republic of Korea.
  • Department of Computer Science and Engineering, Soonchunhyang University, Asan, South Korea.
  • Department of Radiology, Korea University Guro Hospital, Seoul, Republic of Korea.
  • Department of Radiology, Korea University Ansan Hospital, Ansan, Republic of Korea.

Förderung

  • Ministry of Health & Welfare, Republic of Korea

Zitieren

APA

Lee, K. C., Kim, J. H., Hong, S. H., Ahn, K. S., Cho, Y., Kang, W. Y., Kim, B. H., Shim, E., Han, S. B., & Kang, C. H. (2026). Clinical feasibility of camera-type X-ray for intraoperative imaging of hip arthroplasty: a pilot study. Skeletal Radiology, 55(11), 2907-2917. https://doi.org/10.1007/s00256-026-05331-y

Vancouver

Lee KC, Kim JH, Hong SH, Ahn KS, Cho Y, Kang WY, et al. Clinical feasibility of camera-type X-ray for intraoperative imaging of hip arthroplasty: a pilot study. Skeletal Radiology. 2026;55(11):2907-2917. doi:10.1007/s00256-026-05331-y

BibTeX
@article{Lee2026,
  author = {Lee, Kyu-Chong and Kim, Joo Hui and Hong, Seok Ha and Ahn, Kyung-Sik and Cho, Yongwon and Kang, Woo Young and Kim, Baek Hyun and Shim, Euddeum and Han, Seung Beom and Kang, Chang Ho},
  title = {Clinical feasibility of camera-type X-ray for intraoperative imaging of hip arthroplasty: a pilot study},
  journal = {Skeletal Radiology},
  year = {2026},
  volume = {55},
  number = {11},
  pages = {2907--2917},
  doi = {10.1007/s00256-026-05331-y}
}
Kostenlos starten →