EUVIMEDEUVIMED entdecken
Crossref

The diagnostic accuracy of a practical morphometric ratio on MRI for the discoid lateral meniscus

Atilla Hikmet Cilengir, Yasemin Kucukciloglu, Kazim Ayberk Sinci, Atakan Bayir, Asli Irmak Akdogan, Caner Baysan, Ozgur Tosun

Skeletal Radiology · 2025

DOI: 10.1007/s00256-025-05107-w ↗

Kurz gefasst

Fachartikel in der Zeitschrift Skeletal Radiology, 2025. Verfasst von Atilla Hikmet Cilengir und 6 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Medicine, Department of Radiology, Izmir Demokrasi University, Izmir, Türkiye. acilengir@gmail.com. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Menisci, Tibial. Die Arbeit nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: To determine the diagnostic accuracy of a practical morphometric MRI ratio (a/b ratio) for identifying discoid lateral meniscus (DLM). MATERIALS AND METHODS: This retrospective diagnostic accuracy study included 212 adults (mean age 44.8 ± 9.7 years; 56.1% female) who underwent 1.5-T knee MRI between 2020 and 2022. The DLM group (n = 106) was defined according to established MRI criteria, with an equal number of age- and sex-matched controls without discoid morphology. The index test was the a/b ratio, defined as the shortest lateral meniscal body width (a) divided by its medial offset from the lateral tibial spine (b). Additional evaluated morphometric parameters were tibial eminence width, tibial spine heights, and angles. The reference standard was consensus MRI diagnosis by two musculoskeletal radiologists. Diagnostic accuracy was assessed using ROC analysis, and measurement reproducibility was evaluated with intraclass correlation coefficients (ICC). RESULTS: The a/b ratio was significantly higher in DLM than in controls (3.80 ± 5.4 vs. 0.47 ± 0.16; p < 0.001). A cut-off ≥ 0.764 yielded excellent diagnostic accuracy (AUC 0.996, 95% CI 0.991-1.000), with 100% sensitivity and 96.2% specificity. Complete DLM demonstrated markedly higher ratios than incomplete types (12.2 ± 7.4 vs. 1.9 ± 1.8; p < 0.001; AUC 0.990, 95% CI 0.972-1.000). Inter- and intra-observer agreement for the ratio was excellent (ICC 0.935 and 0.972, respectively). Tibial eminence width and lateral tibial spine angle were also greater in DLM (p < 0.001). CONCLUSION: The a/b ratio is a practical and reproducible MRI-based metric with excellent diagnostic accuracy for DLM. Incorporation into routine MRI interpretation may enhance diagnostic confidence and aid preoperative planning.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingMenisci, TibialHumansFemaleReproducibility of ResultsRetrospective StudiesAdultMaleSensitivity and SpecificityMiddle Aged

Stichwörter der Autor:innen

ClassificationDiscoidKneeMagnetic resonance imagingMeniscus

Autor:innen und Institutionen

  • Faculty of Medicine, Department of Radiology, Izmir Demokrasi University, Izmir, Türkiye. acilengir@gmail.com.
  • Faculty of Medicine, Department of Radiology, Near East University, Nicosia, Cyprus.
  • Department of Radiology, Kanuni Sultan Suleyman Training and Research Hospital, Istanbul, Türkiye.
  • Department of Radiology, Izmir Katip Celebi University, Ataturk Training and Research Hospital, Izmir, Türkiye.
  • Faculty of Medicine, Department of Public Health, Ege University, Izmir, Türkiye.

Zitieren

APA

Cilengir, A. H., Kucukciloglu, Y., Sinci, K. A., Bayir, A., Akdogan, A. I., Baysan, C., & Tosun, O. (2025). The diagnostic accuracy of a practical morphometric ratio on MRI for the discoid lateral meniscus. Skeletal Radiology. https://doi.org/10.1007/s00256-025-05107-w

Vancouver

Cilengir AH, Kucukciloglu Y, Sinci KA, Bayir A, Akdogan AI, Baysan C, et al. The diagnostic accuracy of a practical morphometric ratio on MRI for the discoid lateral meniscus. Skeletal Radiology. 2025. doi:10.1007/s00256-025-05107-w

BibTeX
@article{Cilengir2025,
  author = {Cilengir, Atilla Hikmet and Kucukciloglu, Yasemin and Sinci, Kazim Ayberk and Bayir, Atakan and Akdogan, Asli Irmak and Baysan, Caner and Tosun, Ozgur},
  title = {The diagnostic accuracy of a practical morphometric ratio on MRI for the discoid lateral meniscus},
  journal = {Skeletal Radiology},
  year = {2025},
  doi = {10.1007/s00256-025-05107-w}
}
Kostenlos starten →