EUVIMEDEUVIMED entdecken
Crossref

Diagnostic performance of dual-energy Rho/Z CT and cinematic rendering in Achilles tendon rupture: a prospective multi-reader study

Qizheng Wang, Suwei Liu, Yupeng Zhu, Xiaoxi Ji, Yan Zhang, Qiang Zhao, Aihui Di, Yang Lv, Ning Lang

Skeletal Radiology · 2026-05 · 55 (5) · 1059-1071

DOI: 10.1007/s00256-025-05103-0 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Skeletal Radiology, online erschienen am 16.01.2026. Verfasst von Qizheng Wang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Peking University Third Hospital, 49 North Garden Road, Haidian District, 100191, Beijing, People's Republic of China. Hauptthemen laut MEDLINE: Achilles Tendon, Tomography, X-Ray Computed, Tendon Injuries, Radiography, Dual-Energy Scanned Projection. Die Arbeit nennt 39 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: To evaluate the diagnostic performance of dual-energy computed tomography (DECT) Rho/Z mapping and cinematic rendering (CR) for detecting Achilles tendon rupture. MATERIALS AND METHODS: In this prospective study, 117 consecutive patients (median age, 40 years; IQR, 32.8-44.0; range, 17-62) underwent DECT between January and September 2024. MRI served as the reference for rupture diagnosis and quantitative measures (location and gap). For complex/atypical tears (partial tears, avulsion fractures, intratendinous calcifications), operative findings were used as the reference standard. Three independent readers, blinded to the reference, interpreted images in three sessions (grayscale CT, DECT Rho/Z, and CR) to determine rupture presence, location, and gap. Diagnostic metrics (AUC, sensitivity, specificity, accuracy, PPV/NPV) were calculated; Rho/Z cutoffs were derived by ROC analysis. RESULTS: In total, 194 DECT/CR datasets were analyzed (77 bilateral = 154; 40 unilateral = 40). DECT Rho/Z and CR outperformed grayscale CT for rupture detection with AUCs > 0.90 (all P 0.80). Quantitative parameters (80-keV, Sn150-keV, Rho, Zeff) differed significantly between ruptured and intact tendons (all P < 0.001). CONCLUSION: DECT Rho/Z and CR showed strong diagnostic performance versus grayscale CT using MRI/operative findings as references and may provide complementary value in complex cases.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Achilles TendonTomography, X-Ray ComputedTendon InjuriesRadiography, Dual-Energy Scanned ProjectionHumansRuptureProspective StudiesFemaleAdultSensitivity and SpecificityMaleMiddle AgedAdolescentYoung AdultMagnetic Resonance Imaging

Stichwörter der Autor:innen

Achilles tendonCinematic renderingDiagnostic imagingDual-energyQuantitative CT

Autor:innen und Institutionen

  • Department of Radiology, Peking University Third Hospital, 49 North Garden Road, Haidian District, 100191, Beijing, People's Republic of China.
  • Orthopaedic Department, Peking University Third Hospital, 49 North Garden Road, Haidian District, 100191, Beijing, People's Republic of China. lvyang42@126.com.
  • Department of Radiology, Peking University Third Hospital, 49 North Garden Road, Haidian District, 100191, Beijing, People's Republic of China. langning800129@126.com.
  • State Key Laboratory of Vascular Homeostasis and Remodeling, Peking University Third Hospital, Beijing, China. langning800129@126.com.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Wang, Q., Liu, S., Zhu, Y., Ji, X., Zhang, Y., Zhao, Q., Di, A., Lv, Y., & Lang, N. (2026). Diagnostic performance of dual-energy Rho/Z CT and cinematic rendering in Achilles tendon rupture: a prospective multi-reader study. Skeletal Radiology, 55(5), 1059-1071. https://doi.org/10.1007/s00256-025-05103-0

Vancouver

Wang Q, Liu S, Zhu Y, Ji X, Zhang Y, Zhao Q, et al. Diagnostic performance of dual-energy Rho/Z CT and cinematic rendering in Achilles tendon rupture: a prospective multi-reader study. Skeletal Radiology. 2026;55(5):1059-1071. doi:10.1007/s00256-025-05103-0

BibTeX
@article{Wang2026,
  author = {Wang, Qizheng and Liu, Suwei and Zhu, Yupeng and Ji, Xiaoxi and Zhang, Yan and Zhao, Qiang and Di, Aihui and Lv, Yang and Lang, Ning},
  title = {Diagnostic performance of dual-energy Rho/Z CT and cinematic rendering in Achilles tendon rupture: a prospective multi-reader study},
  journal = {Skeletal Radiology},
  year = {2026},
  volume = {55},
  number = {5},
  pages = {1059--1071},
  doi = {10.1007/s00256-025-05103-0}
}
Kostenlos starten →