EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Costal cartilage mimics urate on DECT

Anthony J Doyle, Michel K Nieuwoudt, Jason Woon, Hannah M Matthews, Nicola Dalbeth

Skeletal Radiology · 2025

DOI: 10.1007/s00256-025-04980-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Skeletal Radiology, 2025. Verfasst von Anthony J Doyle und 4 weiteren Autor:innen. Beteiligte Einrichtung: Anatomy and Medical Imaging, Faculty of Medical and Health Sciences, University of Auckland, 85 Park Rd Grafton, Auckland, 1023, New Zealand. a.doyle…. Hauptthemen laut MEDLINE: Uric Acid, Tomography, X-Ray Computed, Costal Cartilage. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Auckland.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To establish whether the material in costal cartilages isoattenuating to urate on dual-energy CT is, in fact, urate. Materials and methods Under the Human Tissue Act, costal cartilage specimens from 12 donated embalmed cadavers were examined with DECT before and after storage in air, ethanol, and saline. Cadaveric tophi were examined as positive controls. The storage fluid was analyzed for urate. Raman spectroscopy was performed. The results were compared using Student t -tests and ANOVA.

Results

For cadavers 1–6, initial DECT isoattenuating volumes were 0.3–1.91 cm 3 (mean 1.1). Three-month delayed volumes for those stored in air were 0.24–1.6 cm 3 (mean 0.95). For those stored in ethanol, all volumes were zero ( p = 0.009). For cadavers 7–12, initial volumes were 0.43–1.45 cm 3 (mean 1.0). Three-month delayed volumes stored in distilled water were 0.13–0.62 cm 3 (mean 0.3). Thirteen-month delayed volumes were 0–0.39 cm 3 (mean 0.14, p = 0.001). Urate in the storage fluid for the costal cartilages was zero but that in the tophus storage fluid was high (1002 and 338 umol/L). The absent 632 cm −1 Raman spectra peak of costal cartilages 1 and 2 confirmed that no urate was present.

Conclusion

The isoattenuating material in costal cartilages on DECT is not urate, but other material that simulates the attenuation profile of urate under certain conditions. In clinical practice, isoattenuating material in costal cartilages on DECT can be regarded as artifactual.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Uric AcidTomography, X-Ray ComputedCostal CartilageHumansCadaverMaleFemaleAgedMiddle AgedSpectrum Analysis, RamanAged, 80 and over

Stichwörter der Autor:innen

ArtefactCostal cartilageDual-energy CTGoutMimicUrate

Substanzen

Uric Acid

Autor:innen und Institutionen

  • Anatomy and Medical Imaging, Faculty of Medical and Health Sciences, University of Auckland, 85 Park Rd Grafton, Auckland, 1023, New Zealand. a.doyle@auckland.ac.nz.
  • Radiology Department, Auckland City Hospital, Te Toka Tumai, 2 Park Rd Grafton, Auckland, 1023, New Zealand. a.doyle@auckland.ac.nz.
  • Science Centre, University of Auckland, 302 - Bldg 302, 23 Symonds St, Auckland, 1010, New Zealand.
  • Anatomy and Medical Imaging, Faculty of Medical and Health Sciences, University of Auckland, 85 Park Rd Grafton, Auckland, 1023, New Zealand.
  • Department of Medicine, Faculty of Medical and Health Sciences, University of Auckland, Room 502-201D, 85 Park Rd Grafton, Auckland, 1023, New Zealand.

Förderung

  • University of Auckland

Zitieren

APA

Doyle, A. J., Nieuwoudt, M. K., Woon, J., Matthews, H. M., & Dalbeth, N. (2025). Costal cartilage mimics urate on DECT. Skeletal Radiology. https://doi.org/10.1007/s00256-025-04980-9

Vancouver

Doyle AJ, Nieuwoudt MK, Woon J, Matthews HM, Dalbeth N. Costal cartilage mimics urate on DECT. Skeletal Radiology. 2025. doi:10.1007/s00256-025-04980-9

BibTeX
@article{Doyle2025,
  author = {Doyle, Anthony J and Nieuwoudt, Michel K and Woon, Jason and Matthews, Hannah M and Dalbeth, Nicola},
  title = {Costal cartilage mimics urate on DECT},
  journal = {Skeletal Radiology},
  year = {2025},
  doi = {10.1007/s00256-025-04980-9}
}
Kostenlos starten →