Performance and reliability comparison: original vs. revised bone reporting and data system (Bone-RADS)
Skeletal Radiology · 2025-08 · 54 (8) · 1681-1688
DOI: 10.1007/s00256-025-04865-x ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Skeletal Radiology, online erschienen am 22.01.2025. Verfasst von Sara Haseli und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Division of Musculoskeletal Imaging and Intervention, University of Washington, Seattle, WA, USA. Hauptthemen laut MEDLINE: Bone Neoplasms, Tomography, X-Ray Computed, Radiology Information Systems. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 26 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVE: To propose a revised bone reporting and data system (Bone-RADS) and evaluate its diagnostic performance and inter-reader reliability compared to the original Bone-RADS for solitary bone lesions on CT. MATERIALS AND METHODS: This retrospective study included 159 adult patients (mean age: 56 ± 19 years; 88 men) who underwent bone biopsy for solitary bone lesions between March 2005 and September 2021. Two radiologists (R1/2) independently categorized the lesions twice, once using the original Bone-RADS and once using the revised version. Lesions were classified as follows: (1, benign; 2, incompletely assessed; 3, indeterminate; 4, malignancy or requiring treatment). The revised Bone-RADS excluded the original criteria for lesion related pain and history of malignancy. Diagnostic performance was assessed using histopathology as the reference standard, and inter-reader reliability was analyzed. RESULTS: The bone lesions included 96 lucent and 63 sclerotic/mixed lesions. Sensitivity showed no significant difference between the original and revised Bone-RADS for both readers across lucent and sclerotic/mixed lesions (all P ≥ .05). However, the specificity of the revised Bone-RADS was significantly higher than that of the original (lucent: 11% vs. 50% [R1], 11% vs. 46% [R2]; sclerotic/mixed: 32% vs. 92% [R1], 32% vs. 86% [R2]). Other performance metrics, including positive/negative predictive value and accuracy, were also higher in the revised Bone-RADS. Inter-reader reliability was higher for the revised Bone-RADS compared to the original (κ = .744 vs .854). CONCLUSION: The revised Bone-RADS significantly improved specificity while maintaining sensitivity compared to the original version.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Division of Musculoskeletal Imaging and Intervention, University of Washington, Seattle, WA, USA.
- OncoRad Research Core, Department of Radiology, University of Washington/Fred Hutchinson Cancer Center, Seattle, WA, USA.
- Department of Radiology, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, South Korea.
- Department of Diagnostic Radiology, Singapore General Hospital, Singapore, Singapore.
- Department of Radiology, Division of Musculoskeletal Imaging and Intervention, University of Washington, Seattle, WA, USA. mchalian@uw.edu.
- OncoRad Research Core, Department of Radiology, University of Washington/Fred Hutchinson Cancer Center, Seattle, WA, USA. mchalian@uw.edu.
Zitieren
APA
Haseli, S., Park, C., Azhideh, A., Karande, G., & Chalian, M. (2025). Performance and reliability comparison: original vs. revised bone reporting and data system (Bone-RADS). Skeletal Radiology, 54(8), 1681-1688. https://doi.org/10.1007/s00256-025-04865-x
Vancouver
Haseli S, Park C, Azhideh A, Karande G, Chalian M. Performance and reliability comparison: original vs. revised bone reporting and data system (Bone-RADS). Skeletal Radiology. 2025;54(8):1681-1688. doi:10.1007/s00256-025-04865-x
BibTeX
@article{Haseli2025,
author = {Haseli, Sara and Park, Chankue and Azhideh, Arash and Karande, Gita and Chalian, Majid},
title = {Performance and reliability comparison: original vs. revised bone reporting and data system (Bone-RADS)},
journal = {Skeletal Radiology},
year = {2025},
volume = {54},
number = {8},
pages = {1681--1688},
doi = {10.1007/s00256-025-04865-x}
}