CT-like images based on T1-weighted gradient echo MRI sequences for the assessment of fractures of the hand and wrist compared to CT
Skeletal Radiology · 2024-12 · 53 (12) · 2607-2615
DOI: 10.1007/s00256-024-04683-7 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Skeletal Radiology, online erschienen am 25.04.2024. Verfasst von N Hesse und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, LMU University Hospital, LMU Munich, Munich, Germany. nina.hesse@med.uni-muenchen.de. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Tomography, X-Ray Computed, Fractures, Bone, Wrist Injuries. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinik München.
Abstract (Originalsprache)
Objective
To evaluate the performance of a 3D T1-weighted gradient-echo (3D T1GRE) computed tomography (CT)-like magnetic resonance imaging (MRI) sequence for detecting and assessing wrist and hand fractures compared to conventional CT.
Methods
Subjects with acute wrist or hand fracture in CT underwent additional 3 T MRI including a CT-like 3D T1GRE sequence and were compared to patients without fractures. Two radiologists assessed fracture morphology on both modalities according to the Arbeitsgemeinschaft Osteosynthese (AO) and graded image quality and diagnostic confidence on a 5-point Likert scale. Besides diagnostic test evaluation, differences in image quality and diagnostic confidence between CT-like MRI and CT were calculated using the Wilcoxon test. Agreement of AO classification between modalities and readers was assessed using Cohen’s Kappa.
Results
Twenty-eight patients with 43 fractures and 43 controls were included. Image quality (3D T1GRE 1.19 ± 0.37 vs. CT 1.22 ± 0.42; p = 0.65) and diagnostic confidence (3D T1GRE 1.28 ± 0.53 vs. CT 1.28 ± 0.55; p = 1.00) were rated excellent for both modalities. Regarding the AO classification, intra- (rater 1 and rater 2, κ = 0.89; 95% CI 0.80–0.97) and interrater agreement were excellent (3D T1GRE, κ = 0.82; 95% CI, 0.70–0.93; CT, κ = 0.85; 95% CI, 0.75–0.94). CT-like MRI showed excellent sensitivity, specificity and accuracy for fracture detection (reader 1: 1.00, 0.92, 0.96; reader 2: 0.98, 0.94, 0.96).
Conclusion
CT-like MRI is a comparable alternative to CT for assessing hand and wrist fractures, offering the advantage of avoiding radiation exposure.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, LMU University Hospital, LMU Munich, Munich, Germany. nina.hesse@med.uni-muenchen.de.
- Department of Diagnostic and Interventional Radiology, Klinikum Rechts der Isar, School of Medicine, Technical University of Munich, Munich, Germany.
- Department of Radiology, LMU University Hospital, LMU Munich, Munich, Germany.
- Department of Neuroradiology, LMU University Hospital, LMU Munich, Munich, Germany.
Förderung
- Universitätsklinik München
Zitieren
APA
Hesse, N., Feuerriegel, G. C., Erber, B., Reidler, P., Gottfried, V., Stohldreier, Y., Schmitt, R., Dietrich, O., Gersing, A. S., & Spiro, J. E. (2024). CT-like images based on T1-weighted gradient echo MRI sequences for the assessment of fractures of the hand and wrist compared to CT. Skeletal Radiology, 53(12), 2607-2615. https://doi.org/10.1007/s00256-024-04683-7
Vancouver
Hesse N, Feuerriegel GC, Erber B, Reidler P, Gottfried V, Stohldreier Y, et al. CT-like images based on T1-weighted gradient echo MRI sequences for the assessment of fractures of the hand and wrist compared to CT. Skeletal Radiology. 2024;53(12):2607-2615. doi:10.1007/s00256-024-04683-7
BibTeX
@article{Hesse2024,
author = {Hesse, N and Feuerriegel, G C and Erber, B and Reidler, P and Gottfried, V and Stohldreier, Y and Schmitt, R and Dietrich, O and Gersing, A S and Spiro, J E},
title = {CT-like images based on T1-weighted gradient echo MRI sequences for the assessment of fractures of the hand and wrist compared to CT},
journal = {Skeletal Radiology},
year = {2024},
volume = {53},
number = {12},
pages = {2607--2615},
doi = {10.1007/s00256-024-04683-7}
}
EUVIMED