Performance of thoracic ultrasonography compared with chest radiography for the detection of rib fractures using computed tomography as a reference standard
Skeletal Radiology · 2024
DOI: 10.1007/s00256-024-04658-8 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Skeletal Radiology, 2024. Verfasst von Evangelia E Vassalou und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Imaging, University Hospital of Heraklion, Voutes, 71110, Heraklion, Crete, Greece. vassalou.e@hotmail.com. Hauptthemen laut MEDLINE: Rib Fractures, Ultrasonography, Tomography, X-Ray Computed, Radiography, Thoracic. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 32 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVE: Although there is growing evidence that ultrasonography is superior to X-ray for rib fractures' detection, X-ray is still indicated as the most appropriate method. This has partially been attributed to a lack of studies using an appropriate reference modality. We aimed to compare the diagnostic accuracy of ultrasonography and X-ray in the detection of rib fractures, considering CT as the reference standard. MATERIALS AND METHODS: Within a 2.5-year period, all consecutive patients with clinically suspected rib fracture(s) following blunt chest trauma and available posteroanterior/anteroposterior X-ray and thoracic CT were prospectively studied and planned to undergo thoracic ultrasonography, by a single operator. All imaging examinations were evaluated for cortical rib fracture(s), and their location was recorded. The cartilaginous rib portions were not assessed. CTs and X-rays were evaluated retrospectively. Concomitant thoracic/extra-thoracic injuries were assessed on CT. Comparisons were performed with the Mann-Whitney U test and Fisher's exact test. RESULTS: Fifty-nine patients (32 males, 27 females; mean age, 53.1 ± 16.6 years) were included. CT, ultrasonography, and X-ray (40 posteroanterior/19 anteroposterior views) diagnosed 136/122/42 rib fractures in 56/54/27 patients, respectively. Ultrasonography and X-ray had sensitivity of 100%/40% and specificity of 89.7%/30.9% for rib fractures' detection. Ultrasound accuracy was 94.9% compared to 35.4% for X-rays (P < .001) in detecting individual rib fractures. Most fractures involved the 4th-9th ribs. Upper rib fractures were most commonly overlooked on ultrasonography. Thoracic cage/spine fractures and haemothorax represented the most common concomitant injuries. CONCLUSION: Ultrasonography appeared to be superior to X-ray for the detection of rib fractures with regard to a reference CT.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medical Imaging, University Hospital of Heraklion, Voutes, 71110, Heraklion, Crete, Greece. vassalou.e@hotmail.com.
- Department of Medical Imaging, General Hospital of Sitia, Xserokamares, 72300, Sitia, Crete, Greece. vassalou.e@hotmail.com.
- Department of Surgical Oncology, University Hospital of Heraklion, Voutes, 71110, Heraklion, Crete, Greece.
- Department of Medical Imaging, University Hospital of Heraklion, Voutes, 71110, Heraklion, Crete, Greece.
Zitieren
APA
Vassalou, E. E., Perysinakis, I., Klontzas, M. E., de Bree, E., & Karantanas, A. H. (2024). Performance of thoracic ultrasonography compared with chest radiography for the detection of rib fractures using computed tomography as a reference standard. Skeletal Radiology. https://doi.org/10.1007/s00256-024-04658-8
Vancouver
Vassalou EE, Perysinakis I, Klontzas ME, de Bree E, Karantanas AH. Performance of thoracic ultrasonography compared with chest radiography for the detection of rib fractures using computed tomography as a reference standard. Skeletal Radiology. 2024. doi:10.1007/s00256-024-04658-8
BibTeX
@article{Vassalou2024,
author = {Vassalou, Evangelia E and Perysinakis, Iraklis and Klontzas, Michail E and de Bree, Eelco and Karantanas, Apostolos H},
title = {Performance of thoracic ultrasonography compared with chest radiography for the detection of rib fractures using computed tomography as a reference standard},
journal = {Skeletal Radiology},
year = {2024},
doi = {10.1007/s00256-024-04658-8}
}
EUVIMED