Deep-learning-reconstructed high-resolution 3D cervical spine MRI for foraminal stenosis evaluation
Skeletal Radiology · 2023-04 · 52 (4) · 725-732
DOI: 10.1007/s00256-022-04211-5 ↗Kurz gefasst
Fachartikel in der Zeitschrift Skeletal Radiology, online erschienen am 21.10.2022. Verfasst von Meghan Jardon und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Imaging, Hospital for Special Surgery, 535 E 70th St, New York, NY, 10021, USA. Hauptthemen laut MEDLINE: Deep Learning, Spinal Stenosis. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 23 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVE: To compare standard-of-care two-dimensional MRI acquisitions of the cervical spine with those from a single three-dimensional MRI acquisition, reconstructed using a deep-learning-based reconstruction algorithm. We hypothesized that the improved image quality provided by deep-learning-based reconstruction would result in improved inter-rater agreement for cervical spine foraminal stenosis compared to conventional two-dimensional acquisitions. MATERIALS AND METHODS: Forty-one patients underwent routine cervical spine MRI with a conventional protocol comprising two-dimensional T2-weighted fast spin echo scans (2 axial planes, 1 sagittal plane), and an isotropic-resolution three-dimensional T2-weighted fast spin echo scan reconstructed over a 4-h time window with a deep-learning-based reconstruction algorithm. Three radiologists retrospectively assessed images for the degree to which motion artifact limited clinical assessment, and foraminal and central stenosis at each level. Inter-rater agreement was analyzed with weighted Fleiss's kappa (k) and comparisons between two-dimensional and three-dimensional sequences were performed with Wilcoxon signed-rank test. RESULTS: Inter-rater agreement for foraminal stenosis was "substantial" for two-dimensional sequences (k = 0.76) and "excellent" for the three-dimensional sequence (k = 0.81). Agreement was "excellent" for both sequences (k = 0.85 and 0.83) for central stenosis. The three-dimensional sequence had less perceptible motion artifact (p ≤ 0.001-0.036). Mean total scan time was 10.8 min for the two-dimensional sequences, and 7.3 min for the three-dimensional sequence. CONCLUSION: Three-dimensional MRI reconstructed with a deep-learning-based algorithm provided "excellent" inter-observer agreement for foraminal and central stenosis, which was at least equivalent to standard-of-care two-dimensional imaging. Three-dimensional MRI with deep-learning-based reconstruction was less prone to motion artifact, with overall scan time savings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology and Imaging, Hospital for Special Surgery, 535 E 70th St, New York, NY, 10021, USA.
- GE Healthcare, Waukesha, WI, USA.
- Biostatistics Core, Research Administration, Hospital for Special Surgery, New York, NY, 10021, USA.
- Department of Radiology and Imaging, Hospital for Special Surgery, 535 E 70th St, New York, NY, 10021, USA. sneagd@hss.edu.
Zitieren
APA
Jardon, M., Tan, E. T., Chazen, J. L., Sahr, M., Wen, Y., Schneider, B., & Sneag, D. B. (2023). Deep-learning-reconstructed high-resolution 3D cervical spine MRI for foraminal stenosis evaluation. Skeletal Radiology, 52(4), 725-732. https://doi.org/10.1007/s00256-022-04211-5
Vancouver
Jardon M, Tan ET, Chazen JL, Sahr M, Wen Y, Schneider B, et al. Deep-learning-reconstructed high-resolution 3D cervical spine MRI for foraminal stenosis evaluation. Skeletal Radiology. 2023;52(4):725-732. doi:10.1007/s00256-022-04211-5
BibTeX
@article{Jardon2023,
author = {Jardon, Meghan and Tan, Ek T and Chazen, J Levi and Sahr, Meghan and Wen, Yan and Schneider, Brandon and Sneag, Darryl B},
title = {Deep-learning-reconstructed high-resolution 3D cervical spine MRI for foraminal stenosis evaluation},
journal = {Skeletal Radiology},
year = {2023},
volume = {52},
number = {4},
pages = {725--732},
doi = {10.1007/s00256-022-04211-5}
}
EUVIMED