Evaluation of MALDI-TOF for identification of Vibrio cholerae and Vibrio parahaemolyticus from growth on agar media
Applied Microbiology and Biotechnology · 2025
DOI: 10.1007/s00253-024-13385-y ↗Kurz gefasst
Evaluationsstudie in der Zeitschrift Applied Microbiology and Biotechnology, 2025. Verfasst von Swapan Banerjee und 4 weiteren Autor:innen. Beteiligte Einrichtung: Vibrio Reference Laboratory, Bureau of Microbial Hazards, Health Canada, Ottawa, ON, Canada. Hauptthemen laut MEDLINE: Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization, Vibrio parahaemolyticus, Vibrio cholerae, Culture Media. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Health Canada.
Abstract (Originalsprache)
Two methods were compared for their ability to accurately identify Vibrio species of interest: whole genome sequencing as the reference method and MALDI-TOF MS (matrix-assisted laser desorption/ionization-time of flight mass spectrometry) proteome fingerprinting. The accuracy of mass spectrometry–based identification method was evaluated for its ability to accurately identify isolates of Vibrio cholerae and Vibrio parahaemolyticus . Identification result of each isolate obtained by mass spectrometry was compared to identification by whole genome sequencing (WGS). The MALDI-TOF MS system had excellent performance for identification of V. cholerae and V. parahaemolyticus isolates grown on a non-selective solid agar media. Unlike the biochemical characterization performed by API20E. In this study, 161 isolates ( V. cholerae, n = 33; V. parahaemolyticus, n = 102; V. spp., n = 23; other enteropathogens, Salmonella and E. coli , n = 3) were used to assess accuracy. The MALDI-TOF MS system was able to accurately identify 100% (33/33) of the V. cholerae isolates and 99.9% (101/102) of V. parahaemolyticus isolates, with 100% for both sensitivity and specificity for V. cholerae and 99% sensitivity and 98% specificity for V. parahaemolyticus . Thus, mass spectrometry for bacterial identification is comparable to the WGS. Furthermore, in comparison to a biochemical characterization, the use of MALDI-TOF MS system shortens the analysis time from over 72 h to less than 24 h. Key points • V. cholerae and V. parahaemolyticus were successfully ID-ed by MALDI-TOF • MALDI-TOF sensitivity and specificity parallels the WGS method of identification • MALDI-TOF is several days faster than the battery of culture-dependent methods
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Vibrio Reference Laboratory, Bureau of Microbial Hazards, Health Canada, Ottawa, ON, Canada.
- Genomics Laboratory, Bureau of Microbial Hazards, Health Canada, Ottawa, ON, Canada.
- Vibrio Reference Laboratory, Bureau of Microbial Hazards, Health Canada, Ottawa, ON, Canada. bojan.shutinoski@hc-sc.gc.ca.
Förderung
- Health Canada
Zitieren
APA
Banerjee, S., Flint, A., Brosseau, M. B., Weedmark, K., & Shutinoski, B. (2025). Evaluation of MALDI-TOF for identification of Vibrio cholerae and Vibrio parahaemolyticus from growth on agar media. Applied Microbiology and Biotechnology. https://doi.org/10.1007/s00253-024-13385-y
Vancouver
Banerjee S, Flint A, Brosseau MB, Weedmark K, Shutinoski B. Evaluation of MALDI-TOF for identification of Vibrio cholerae and Vibrio parahaemolyticus from growth on agar media. Applied Microbiology and Biotechnology. 2025. doi:10.1007/s00253-024-13385-y
BibTeX
@article{Banerjee2025,
author = {Banerjee, Swapan and Flint, Annika and Brosseau, Madeleine B and Weedmark, Kelly and Shutinoski, Bojan},
title = {Evaluation of MALDI-TOF for identification of Vibrio cholerae and Vibrio parahaemolyticus from growth on agar media},
journal = {Applied Microbiology and Biotechnology},
year = {2025},
doi = {10.1007/s00253-024-13385-y}
}
EUVIMED