Radiographic imaging in pediatric suspected foreign body ingestion: potential for dose reduction through collimation and exposure strategies
Pediatric Radiology · 20.08.2026 · 56 (12) · 2764-2774
DOI: 10.1007/s00247-026-06751-7 ↗Kurz gefasst
Fachartikel in der Zeitschrift Pediatric Radiology, online erschienen am 20.08.2026. Verfasst von Max-Johann Sturm und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Str. 6, Wurzburg, D-97080, Germany. Sturm_M@ukw.d…. Hauptthemen laut MEDLINE: Foreign Bodies, Radiation Dosage, Radiography. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum Würzburg.
Abstract (Originalsprache)
Background
Foreign body ingestion constitutes a common emergency in children. Radiography is essential for confirming presence, type, and location of ingested objects. International guidelines recommend broad anatomical coverage from the neck to the pelvis; however, the impact of radiographic exposure parameters and collimation on radiation dose remains underexplored.
Objective
To evaluate the effects of different scan protocols on radiation dose in pediatric foreign body ingestion. Materials and methods Two-hundred-twenty-one radiographs from 183 pediatric patients (median age 2.8 years [interquartile range 1.5–5.5 years]; 112 males, 71 females) performed between September 2019 and April 2025 were retrospectively analyzed. Radiographs were categorized as neck–upper abdomen, extended collimation including pelvis, or abdomen only. Notably, the first two protocols used chest radiograph exposure parameters. Data included patient demographics, foreign body type and location, radiographic protocol, dose-area product, and estimated effective dose.
Results
A foreign body was detected in 55.7% of radiographs, most of them in the stomach (59.4%). Coins were most common (31.7%), followed by button batteries (13.8%) and magnets (12.2%). Dose-area products were comparable between standard neck-to-upper-abdomen and extended neck-to-pelvis collimation but were markedly higher for abdomen-only imaging ( P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Str. 6, Wurzburg, D-97080, Germany. Sturm_M@ukw.de.
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Str. 6, Wurzburg, D-97080, Germany.
- Department of Radiation Oncology, University Hospital Würzburg, Wurzburg, Germany.
- Department of Pediatrics, University Hospital Würzburg, Wurzburg, Germany.
Förderung
- Universitätsklinikum Würzburg
Zitieren
APA
Sturm, M. J., Benoit, C., Grunz, J. P., Weick, S., Müller-Reichart, F., Dick, A., Andres, O., Bley, T. A., & Huflage, H. (2026). Radiographic imaging in pediatric suspected foreign body ingestion: potential for dose reduction through collimation and exposure strategies. Pediatric Radiology, 56(12), 2764-2774. https://doi.org/10.1007/s00247-026-06751-7
Vancouver
Sturm MJ, Benoit C, Grunz JP, Weick S, Müller-Reichart F, Dick A, et al. Radiographic imaging in pediatric suspected foreign body ingestion: potential for dose reduction through collimation and exposure strategies. Pediatric Radiology. 2026;56(12):2764-2774. doi:10.1007/s00247-026-06751-7
BibTeX
@article{Sturm2026,
author = {Sturm, Max-Johann and Benoit, Clemens and Grunz, Jan-Peter and Weick, Stefan and Müller-Reichart, Franziska and Dick, Anke and Andres, Oliver and Bley, Thorsten Alexander and Huflage, Henner},
title = {Radiographic imaging in pediatric suspected foreign body ingestion: potential for dose reduction through collimation and exposure strategies},
journal = {Pediatric Radiology},
year = {2026},
volume = {56},
number = {12},
pages = {2764--2774},
doi = {10.1007/s00247-026-06751-7}
}
EUVIMED