Reduction of iodinated contrast waste, cost, and greenhouse gas emissions using imaging bulk packaging in a pediatric hospital
Pediatric Radiology · 2026
DOI: 10.1007/s00247-026-06654-7 ↗Kurz gefasst
Fachartikel in der Zeitschrift Pediatric Radiology, 2026. Verfasst von Sakura M Noda und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University of Washington, M/S MA.7.220 PO Box 5371, Seattle, WA, 98145-5005, USA. sakuran@uw.edu. Hauptthemen laut MEDLINE: Contrast Media, Tomography, X-Ray Computed, Hospitals, Pediatric, Greenhouse Gases. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 23 Literaturangaben.
Abstract (Originalsprache)
Background
There are environmental and financial benefits to reducing iodinated contrast media (ICM) waste. While Imaging Bulk Package (IBP) bottles have been demonstrated to reduce contrast waste in adult hospitals, lower computed tomography (CT) volumes and smaller contrast doses pose challenges for utilizing IBP in children’s hospitals.
Objective
Primary outcome: quantification of CT contrast waste during a 6-month period at a single children’s hospital. Secondary outcomes: quantification of single-use product waste and greenhouse gas emissions, identification of the 12-h periods of highest contrast use, and estimation of reductions in contrast waste, single-use product use, costs, and greenhouse gas emissions by using IBP ICM during peak hours. Materials and methods All contrast-enhanced CT performed from January through June 2025 were reviewed. Volume of contrast wasted was calculated. The 12-h time period with the highest contrast-enhanced CT volume was determined. Reductions in contrast waste, single-use products, cost, and greenhouse gas emissions by using IBP ICM during these peak hours were estimated.
Results
Approximately 291 contrast-enhanced CT exams were performed per month. Mean contrast waste was 37 mL per study, totaling 66 L of wasted contrast over 6 months. Peak hours were 9 AM to 9 PM on weekdays. The mean ICM waste per exam was 37 mL using single-dose bottles versus 17 mL using IBP bottles during peak hours ( P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, University of Washington, M/S MA.7.220 PO Box 5371, Seattle, WA, 98145-5005, USA. sakuran@uw.edu.
- Department of Radiology, Seattle Children's Hospital, Seattle, USA. sakuran@uw.edu.
- Department of Civil and Environmental Engineering, Northeastern University, Boston, USA.
- Department of Radiology, Seattle Children's Hospital, Seattle, USA.
- Department of Radiology, University of Washington, M/S MA.7.220 PO Box 5371, Seattle, WA, 98145-5005, USA.
Zitieren
APA
Noda, S. M., Eckelman, M. J., Porter, P., Dyba, J., Iyer, R. S., Phillips, G. S., & Kim, H. H. R. (2026). Reduction of iodinated contrast waste, cost, and greenhouse gas emissions using imaging bulk packaging in a pediatric hospital. Pediatric Radiology. https://doi.org/10.1007/s00247-026-06654-7
Vancouver
Noda SM, Eckelman MJ, Porter P, Dyba J, Iyer RS, Phillips GS, et al. Reduction of iodinated contrast waste, cost, and greenhouse gas emissions using imaging bulk packaging in a pediatric hospital. Pediatric Radiology. 2026. doi:10.1007/s00247-026-06654-7
BibTeX
@article{Noda2026,
author = {Noda, Sakura M and Eckelman, Matthew J and Porter, Pauline and Dyba, Jaime and Iyer, Ramesh S and Phillips, Grace S and Kim, Helen H R},
title = {Reduction of iodinated contrast waste, cost, and greenhouse gas emissions using imaging bulk packaging in a pediatric hospital},
journal = {Pediatric Radiology},
year = {2026},
doi = {10.1007/s00247-026-06654-7}
}
EUVIMED