Fluoroscopically guided jejunal tube placement via percutaneous gastrostomy in children: technical success, safety, and procedural parameters
Pediatric Radiology · 2026
DOI: 10.1007/s00247-026-06572-8 ↗Kurz gefasst
Fachartikel in der Zeitschrift Pediatric Radiology, 2026. Verfasst von Michael Esser und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology, Pediatric Radiology, University Hospital Tübingen, Hoppe-Seyler-Str. 3, Tübingen, 72076, Germa…. Hauptthemen laut MEDLINE: Gastrostomy, Radiography, Interventional, Intubation, Gastrointestinal, Jejunum. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum Tübingen.
Themen: Kinderkrankenpflege
Abstract (Originalsprache)
Background
Fluoroscopically guided jejunal tube placement via percutaneous endoscopic gastrostomy (PEG-J) provides minimally invasive post-pyloric access in children. Limited data exist regarding routine application and procedural risks.
Objective
To evaluate the safety and technical success of PEG-J in pediatric patients, performed without general anesthesia or sedation. Materials and methods All pediatric cases of fluoroscopically guided PEG-J procedures performed between 2011 and 2025 were included. Fluoroscopic images were reviewed to determine the final position of the tube tip. Technical success, complications, anatomical variants, and tube patency were assessed. Fluoroscopy time and dose area product (DAP) were documented.
Results
A total of 126 PEG-J procedures in 60 children (36 males) were analyzed. The technical success rate was 85% (107/126) with final tube tip placement in the jejunum in 88 cases (82%) and in the duodenum in 19 cases (18%). Nineteen procedures (15%) were unsuccessful, including six with documented anatomical causes (steep vertical duodenal entry, n =2; malrotation, hiatus hernia, hooked stomach in superior mesenteric artery syndrome, steep take-off of the jejunum with kinking of the tube at the ligament of Treitz, n =1 each) and 13 without documented reasons. The median fluoroscopy time was 5 min 24 s (range, 2 s–37 min), at a frame rate of 0.5 frames per second. The median DAP was 6.1 cGy·cm 2 (range, 0.08–343 cGy·cm 2 ).
Conclusion
Fluoroscopically guided PEG-J placement is a safe and effective procedure in pediatric patients, with high technical success and low radiation exposure. Graphical Abstract
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Diagnostic and Interventional Radiology, Pediatric Radiology, University Hospital Tübingen, Hoppe-Seyler-Str. 3, Tübingen, 72076, Germany. michael.esser@med.uni-tuebingen.de.
- Department of Diagnostic and Interventional Radiology, Pediatric Radiology, University Hospital Tübingen, Hoppe-Seyler-Str. 3, Tübingen, 72076, Germany.
- Pediatric Gastroenterology and Hepatology, Department of Haematology and Oncology, University Children's Hospital Tübingen, Tübingen, Germany.
Förderung
- Universitätsklinikum Tübingen
Zitieren
APA
Esser, M., Spogis, J., Hilberath, J., Schäfer, J. F., & Tsiflikas, I. (2026). Fluoroscopically guided jejunal tube placement via percutaneous gastrostomy in children: technical success, safety, and procedural parameters. Pediatric Radiology. https://doi.org/10.1007/s00247-026-06572-8
Vancouver
Esser M, Spogis J, Hilberath J, Schäfer JF, Tsiflikas I. Fluoroscopically guided jejunal tube placement via percutaneous gastrostomy in children: technical success, safety, and procedural parameters. Pediatric Radiology. 2026. doi:10.1007/s00247-026-06572-8
BibTeX
@article{Esser2026,
author = {Esser, Michael and Spogis, Jakob and Hilberath, Johannes and Schäfer, Jürgen F and Tsiflikas, Ilias},
title = {Fluoroscopically guided jejunal tube placement via percutaneous gastrostomy in children: technical success, safety, and procedural parameters},
journal = {Pediatric Radiology},
year = {2026},
doi = {10.1007/s00247-026-06572-8}
}
EUVIMED