EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY 4.0

Feasibility and accuracy of the fully automated three-dimensional echocardiography right ventricular quantification software in children: validation against cardiac magnetic resonance

Qian Liu, Zhiwei Zheng, Yiwei Zhang, Anjun Wu, Jie Lou, Xin Chen, Yating Yuan, Mingxing Xie, Li Zhang, Peng Sun, Wei Sun, Qing Lv

Pediatric Radiology · 18.07.2025 · 55 (12) · 2566-2578

DOI: 10.1007/s00247-025-06330-2 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Pediatric Radiology, online erschienen am 18.07.2025. Verfasst von Qian Liu und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Clinical Research Center fo…. Hauptthemen laut MEDLINE: Echocardiography, Three-Dimensional, Software, Image Interpretation, Computer-Assisted, Heart Ventricles. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Hubei Province, Wuhan Science and Technology Innovation Bureau - Dawn project program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Previous studies have confirmed that fully automated three-dimensional echocardiography (3DE) right ventricular (RV) quantification software can accurately assess adult RV function. However, data on its accuracy in children are scarce.

Objective

This study aimed to test the accuracy of the software in children using cardiac magnetic resonance (MR) as the gold standard. Materials and methods This study prospectively enrolled 82 children who underwent both echocardiography and cardiac MR within 24 h. The RV end-diastolic volume (EDV), end-systolic volume (ESV), and ejection fraction (EF) were obtained using the novel 3DE-RV quantification software and compared with cardiac MR values across different groups.

Results

The novel 3DE-RV quantification software was feasible in all 82 children (100%). Fully automated analysis was achieved in 35% patients with an analysis time of 8 ± 2 s and 100% reproducibility. Manual editing was necessary in the remaining 65% patients. The 3DE-derived RV volumes and EF correlated well with cardiac MR measurements (RVEDV, r =0.93; RVESV, r =0.90; RVEF, r =0.82; all P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Echocardiography, Three-DimensionalSoftwareImage Interpretation, Computer-AssistedHeart VentriclesVentricular Dysfunction, RightMagnetic Resonance ImagingMagnetic Resonance Imaging, CineHumansMaleFemaleFeasibility StudiesChildReproducibility of ResultsChild, PreschoolProspective StudiesInfantAdolescent

Stichwörter der Autor:innen

Artificial intelligenceCardiac magnetic resonanceChildrenRight ventricular functionRight ventricular volumeThree-dimensional echocardiography

Autor:innen und Institutionen

  • Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Clinical Research Center for Medical Imaging in Hubei Province, Hubei Province Key Laboratory of…
  • Department of Emergency Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1277 Jiefang Avenue, Wuhan, 430022, China.
  • Department of Ultrasound, Wuhan No.1 Hospital, Wuhan, China.
  • Clinical Research Center for Medical Imaging in Hubei Province, Wuhan, China.
  • Hubei Province Key Laboratory of Molecular Imaging, Wuhan, China.
  • Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.

Förderung

  • National Natural Science Foundation of China
  • Natural Science Foundation of Hubei Province
  • Wuhan Science and Technology Innovation Bureau - Dawn project program

Zitieren

APA

Liu, Q., Zheng, Z., Zhang, Y., Wu, A., Lou, J., Chen, X., Yuan, Y., Xie, M., Zhang, L., Sun, P., Sun, W., & Lv, Q. (2025). Feasibility and accuracy of the fully automated three-dimensional echocardiography right ventricular quantification software in children: validation against cardiac magnetic resonance. Pediatric Radiology, 55(12), 2566-2578. https://doi.org/10.1007/s00247-025-06330-2

Vancouver

Liu Q, Zheng Z, Zhang Y, Wu A, Lou J, Chen X, et al. Feasibility and accuracy of the fully automated three-dimensional echocardiography right ventricular quantification software in children: validation against cardiac magnetic resonance. Pediatric Radiology. 2025;55(12):2566-2578. doi:10.1007/s00247-025-06330-2

BibTeX
@article{Liu2025,
  author = {Liu, Qian and Zheng, Zhiwei and Zhang, Yiwei and Wu, Anjun and Lou, Jie and Chen, Xin and Yuan, Yating and Xie, Mingxing and Zhang, Li and Sun, Peng and Sun, Wei and Lv, Qing},
  title = {Feasibility and accuracy of the fully automated three-dimensional echocardiography right ventricular quantification software in children: validation against cardiac magnetic resonance},
  journal = {Pediatric Radiology},
  year = {2025},
  volume = {55},
  number = {12},
  pages = {2566--2578},
  doi = {10.1007/s00247-025-06330-2}
}
Kostenlos starten →