EUVIMEDEUVIMED entdecken
Crossref

The impact of high-frequency transducers on the sonographic measurements of the pyloric muscle thickness in infants

Ayat Yousef iD, Alan Daneman, Afsaneh Amirabadi, Ricardo Faingold iD

Pediatric Radiology · 2024

DOI: 10.1007/s00247-024-05881-0 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pediatric Radiology, 2024. Verfasst von Ayat Yousef und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic Imaging, The Hospital for Sick Children, Toronto, ON, Canada. Hauptthemen laut MEDLINE: Ultrasonography, Pylorus, Pyloric Stenosis, Hypertrophic, Transducers. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 13 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Ultrasound is the modality of choice for the diagnosis of hypertrophic pyloric stenosis (HPS). The evolution of high-frequency transducers in ultrasound has led to inconsistent ways of measuring the pylorus. OBJECTIVE: To standardize the measurements and evaluate the appearance of the normal and hypertrophied pylorus with high-frequency transducers. MATERIALS AND METHODS: We retrospectively analyzed abdominal ultrasounds of infants with suspected HPS from January 2019-December 2020. We classified the layers of the pylorus while assessing the stratified appearance. Two pediatric radiologists measured the muscle thickness of the pylorus independently by two methods for interrater agreement. Measurement (a) includes the muscularis propria and muscularis mucosa. Measurement (b) includes only the muscularis propria. We also evaluated the echogenicity of the muscularis propria. The interrater agreement, mean, range of the muscle thickness, and the diagnostic accuracy of the two sets of measurements were calculated. RESULTS: We included 300 infants (114 F:186 M), 59 with HPS and 241 normal cases. There was a strong agreement between the readers assessed in the first 100 cases, and ICC was 0.99 (95% CI, 0.98-0.99). Measurement (a), median thickness is 2.4 mm in normal cases and 4.8 mm in HPS. Measurement (b), median thickness is 1.4 mm in normal cases and 4.0 mm in HPS. Measurement (a) has an accuracy of 89.7% (95% CI, 85.7-92.8%) with 98.3% sensitivity and 87.6% specificity. Measurement (b) has an accuracy of 98.0% (95% CI, 95.7-99.3%) with 89.8% sensitivity and 100.0% specificity. The pylorus stratification is preserved in all normal cases and 31/59 (52.5%) cases of HPS. There was complete/partial loss of stratification in 28/59 (47.5%) cases of HPS. In all HPS cases, the muscularis propria was echogenic. CONCLUSION: Measuring the muscularis propria solely has a better diagnostic accuracy, decreasing the overlap of negative and positive cases. The loss of pyloric wall stratification and echogenic muscularis propria is only seen in HPS.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

UltrasonographyPylorusPyloric Stenosis, HypertrophicTransducersHumansRetrospective StudiesMaleFemaleInfantInfant, NewbornSensitivity and Specificity

Stichwörter der Autor:innen

Abdominal ultrasoundDiagnostic criteriaHPS (hypertrophic pyloric stenosis)High-frequency US transducersPylorusTransverse muscle thickness

Autor:innen und Institutionen

  • Department of Diagnostic Imaging, The Hospital for Sick Children, Toronto, ON, Canada.
  • Department of Medical Imaging, University of Toronto, 555 University Ave, Toronto, ON, M5G 1X8, Canada.
  • Department of Diagnostic Imaging, The Hospital for Sick Children, Toronto, ON, Canada. ricardo.faingold@sickkids.ca.
  • Department of Medical Imaging, University of Toronto, 555 University Ave, Toronto, ON, M5G 1X8, Canada. ricardo.faingold@sickkids.ca.

ORCID-Profile: Ayat Yousef, Ricardo Faingold

Zitieren

APA

Yousef, A., Daneman, A., Amirabadi, A., & Faingold, R. (2024). The impact of high-frequency transducers on the sonographic measurements of the pyloric muscle thickness in infants. Pediatric Radiology. https://doi.org/10.1007/s00247-024-05881-0

Vancouver

Yousef A, Daneman A, Amirabadi A, Faingold R. The impact of high-frequency transducers on the sonographic measurements of the pyloric muscle thickness in infants. Pediatric Radiology. 2024. doi:10.1007/s00247-024-05881-0

BibTeX
@article{Yousef2024,
  author = {Yousef, Ayat and Daneman, Alan and Amirabadi, Afsaneh and Faingold, Ricardo},
  title = {The impact of high-frequency transducers on the sonographic measurements of the pyloric muscle thickness in infants},
  journal = {Pediatric Radiology},
  year = {2024},
  doi = {10.1007/s00247-024-05881-0}
}
Kostenlos starten →