EUVIMEDEUVIMED entdecken
Crossref

Pilot study to determine whether reduced-dose photon-counting detector chest computed tomography can reliably display Brody II score imaging findings for children with cystic fibrosis at radiation doses that approximate radiographs

Kelly K Horst iD, Nathan C Hull, Paul G Thacker, Nadir Demirel, Lifeng Yu, Jennifer S McDonald, Nicholas B Larson, Cynthia H McCollough, Joel G Fletcher

Pediatric Radiology · 2023

DOI: 10.1007/s00247-022-05574-6 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pediatric Radiology, 2023. Verfasst von Kelly K Horst und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Pediatric Radiology Division, Mayo Clinic, 200 First St. SW, Rochester, MN, 55905, USA. Horst.Kelly@mayo.edu. Hauptthemen laut MEDLINE: Cystic Fibrosis, Bronchiectasis. Die Arbeit wurde bisher 42-mal zitiert (Crossref) und nennt 54 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: The Brody II score uses chest CT to guide therapeutic changes in children with cystic fibrosis; however, patients and providers are often reticent to undergo chest CT given concerns about radiation. OBJECTIVE: We sought to determine the ability of a reduced-dose photon-counting detector (PCD) chest CT protocol to reproducibly display pulmonary disease severity using the Brody II score for children with cystic fibrosis (CF) scanned at radiation doses similar to those of a chest radiograph. MATERIALS AND METHODS: Pediatric patients with CF underwent non-contrast reduced-dose chest PCD-CT. Volumetric inspiratory and expiratory scans were obtained without sedation or anesthesia. Three pediatric radiologists with Certificates of Added Qualification scored each scan on an ordinal scale and assigned a Brody II score to grade bronchiectasis, peribronchial thickening, parenchymal opacity, air trapping and mucus plugging. We report image-quality metrics using descriptive statistics. To calculate inter-rater agreement for Brody II scoring, we used the Krippendorff alpha and intraclass correlation coefficient (ICC). RESULTS: Fifteen children with CF underwent reduced-dose PCD chest CT in both inspiration and expiration (mean age 8.9 years, range, 2.5-17.5 years; 4 girls). Mean volumetric CT dose index (CTDIvol) was 0.07 ± 0.03 mGy per scan. Mean effective dose was 0.12 ± 0.04 mSv for the total examination. All three readers graded spatial resolution and noise as interpretable on lung windows. The average Brody II score was 12.5 (range 4-19), with moderate inter-reader reliability (ICC of 0.61 [95% CI=0.27, 0.84]). Inter-rater reliability was moderate to substantial for bronchiectasis (0.52), peribronchial thickening (0.55), presence of opacity (0.62) and air trapping (0.70) and poor for mucus plugging (0.09). CONCLUSION: Reduced-dose PCD-CT permits diagnostic image quality and reproducible identification of Brody II scoring imaging findings at radiation doses similar to those for chest radiography.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cystic FibrosisBronchiectasisFemaleHumansChildPilot ProjectsReproducibility of ResultsTomography, X-Ray ComputedLungRadiation Dosage

Stichwörter der Autor:innen

Brody II scoreChildrenComputed tomographyCystic fibrosisLungsPhoton-counting detector computed tomographyRadiation dose

Autor:innen und Institutionen

  • Department of Radiology, Pediatric Radiology Division, Mayo Clinic, 200 First St. SW, Rochester, MN, 55905, USA. Horst.Kelly@mayo.edu.
  • Department of Radiology, Pediatric Radiology Division, Mayo Clinic, 200 First St. SW, Rochester, MN, 55905, USA.
  • Department of Pediatrics, Pediatric Pulmonology Division, Mayo Clinic, Rochester, MN, USA.
  • Department of Radiology, Mayo Clinic, Rochester, MN, USA.
  • Division of Biomedical Statistics and Informatics, Mayo Clinic, Rochester, MN, USA.

ORCID-Profile: Kelly K Horst

Zitieren

APA

Horst, K. K., Hull, N. C., Thacker, P. G., Demirel, N., Yu, L., McDonald, J. S., Larson, N. B., McCollough, C. H., & Fletcher, J. G. (2023). Pilot study to determine whether reduced-dose photon-counting detector chest computed tomography can reliably display Brody II score imaging findings for children with cystic fibrosis at radiation doses that approximate radiographs. Pediatric Radiology. https://doi.org/10.1007/s00247-022-05574-6

Vancouver

Horst KK, Hull NC, Thacker PG, Demirel N, Yu L, McDonald JS, et al. Pilot study to determine whether reduced-dose photon-counting detector chest computed tomography can reliably display Brody II score imaging findings for children with cystic fibrosis at radiation doses that approximate radiographs. Pediatric Radiology. 2023. doi:10.1007/s00247-022-05574-6

BibTeX
@article{Horst2023,
  author = {Horst, Kelly K and Hull, Nathan C and Thacker, Paul G and Demirel, Nadir and Yu, Lifeng and McDonald, Jennifer S and Larson, Nicholas B and McCollough, Cynthia H and Fletcher, Joel G},
  title = {Pilot study to determine whether reduced-dose photon-counting detector chest computed tomography can reliably display Brody II score imaging findings for children with cystic fibrosis at radiation doses that approximate radiographs},
  journal = {Pediatric Radiology},
  year = {2023},
  doi = {10.1007/s00247-022-05574-6}
}
Kostenlos starten →