Intranodal cone-beam computed tomographic lymphangiography with water-soluble iodinated contrast agent for evaluating chylothorax in infants — preliminary experience at a single institution
Pediatric Radiology · 2023-01 · 53 (1) · 179-183
DOI: 10.1007/s00247-022-05441-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift Pediatric Radiology, online erschienen am 14.07.2022. Verfasst von Dicken Wong und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology, Kwong Wah Hospital, Hong Kong, Hong Kong. Hauptthemen laut MEDLINE: Chylothorax, Transposition of Great Vessels. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 5 Literaturangaben.
Abstract (Originalsprache)
This brief report demonstrates the diagnostic utility of cone-beam CT lymphangiography (CBCTL) with intranodal injection of water-soluble iodinated contrast agent for assessing lymphatic disorders in two infants who were contraindicated for MRI and oil-based contrast agent. Both infants had dextro-transposition of the great arteries (d-TGA) and presented with high-output chylothoraces that were recalcitrant to conservative medical therapy. Both infants were diagnosed with central lymphatic flow disorder based on the CBCTL findings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Diagnostic and Interventional Radiology, Kwong Wah Hospital, Hong Kong, Hong Kong.
- Department of Radiology, Hong Kong Children's Hospital, 2/F, Block B, 1 Shing Cheong Road, Kowloon Bay, Hong Kong, Hong Kong. gwevin@gmail.com.
- Division of Paediatric Cardiology, Department of Paediatrics and Adolescent Medicine, Hong Kong Children's Hospital, Hong Kong, Hong Kong.
- Department of Radiology, Hong Kong Children's Hospital, 2/F, Block B, 1 Shing Cheong Road, Kowloon Bay, Hong Kong, Hong Kong.
ORCID-Profile: Kin Fen Kevin Fung
Zitieren
APA
Wong, D., Fung, K. F. K., Chen, H. R., Lun, K. S., & Kan, Y. L. E. (2023). Intranodal cone-beam computed tomographic lymphangiography with water-soluble iodinated contrast agent for evaluating chylothorax in infants — preliminary experience at a single institution. Pediatric Radiology, 53(1), 179-183. https://doi.org/10.1007/s00247-022-05441-4
Vancouver
Wong D, Fung KFK, Chen HR, Lun KS, Kan YLE. Intranodal cone-beam computed tomographic lymphangiography with water-soluble iodinated contrast agent for evaluating chylothorax in infants — preliminary experience at a single institution. Pediatric Radiology. 2023;53(1):179-183. doi:10.1007/s00247-022-05441-4
BibTeX
@article{Wong2023,
author = {Wong, Dicken and Fung, Kin Fen Kevin and Chen, Hay-Son Robin and Lun, Kin Sing and Kan, Yee Ling Elaine},
title = {Intranodal cone-beam computed tomographic lymphangiography with water-soluble iodinated contrast agent for evaluating chylothorax in infants — preliminary experience at a single institution},
journal = {Pediatric Radiology},
year = {2023},
volume = {53},
number = {1},
pages = {179--183},
doi = {10.1007/s00247-022-05441-4}
}
EUVIMED