Computed Tomography-Derived Normative Values of Right Ventricular Outflow Tract Structures in the Pediatric Population
Pediatric Cardiology · 2025
DOI: 10.1007/s00246-024-03456-2 ↗Kurz gefasst
Fachartikel in der Zeitschrift Pediatric Cardiology, 2025. Verfasst von Natalie Soszyn und 5 weiteren Autor:innen. Beteiligte Einrichtung: The Heart Institute, Children's Hospital Colorado, School of Medicine, University of Colorado Denver Anschutz Medical Campus, 13123 E 16th Ave, Auror…. Hauptthemen laut MEDLINE: Heart Ventricles, Tomography, X-Ray Computed, Pulmonary Valve, Pulmonary Artery. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 18 Literaturangaben.
Abstract (Originalsprache)
Recent advances in available percutaneous device technology require accurate measurements and quantification of relationships between right ventricular outflow tract (RVOT) structures in children with and without congenital heart disease to determine device suitability. To date, no population study has described normal reference ranges of these measurements by computed tomography (CT). We aimed to establish normative values for four CT-derived measurements between RVOT structures from a heterogeneous population without heart disease and develop z scores useful for clinical practice. Patients without heart disease who underwent cardiac CT between April 2014 and February 2021 at Children's Hospital Colorado were included. Distance between the right ventricular (RV) apex to pulmonary valve (PV), PV to pulmonary trunk bifurcation, and bifurcation to the right and left pulmonary artery was measured. Previously validated models were used to normalize the measurements and calculate Z scores. Each measurement was plotted against BSA and Z scores distributions were used as reference lines. Three-hundred and sixty-four healthy patients with a mean age of 8.8 years (range 1-21), 58% male, and BSA of 1 m2 (range 0.4-2.1) were analyzed. The Haycock formula was used to present data as predicted values for a given BSA and within equations relating each measurement to BSA. Predicted values and Z-score boundaries for all measurements are presented.We report CT-derived normative data for four measurements between RVOT structures from a heterogeneous cohort of healthy children. Knowledge of this normative data will be useful in both determining device fit and customizing future devices to accommodate the diverse pediatric size range.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- The Heart Institute, Children's Hospital Colorado, School of Medicine, University of Colorado Denver Anschutz Medical Campus, 13123 E 16th Ave, Aurora, CO, 80045-2560, USA.
- The Heart Institute, Children's Hospital Colorado, School of Medicine, University of Colorado Denver Anschutz Medical Campus, 13123 E 16th Ave, Aurora, CO, 80045-2560, USA. jenny.zablah@childrenscolorado.org.
Zitieren
APA
Soszyn, N., Schweigert, J., Franco, S. R., Morgan, G. J., Mitchell, M., & Zablah, J. E. (2025). Computed Tomography-Derived Normative Values of Right Ventricular Outflow Tract Structures in the Pediatric Population. Pediatric Cardiology. https://doi.org/10.1007/s00246-024-03456-2
Vancouver
Soszyn N, Schweigert J, Franco SR, Morgan GJ, Mitchell M, Zablah JE. Computed Tomography-Derived Normative Values of Right Ventricular Outflow Tract Structures in the Pediatric Population. Pediatric Cardiology. 2025. doi:10.1007/s00246-024-03456-2
BibTeX
@article{Soszyn2025,
author = {Soszyn, Natalie and Schweigert, Justin and Franco, Salvador R and Morgan, Gareth J and Mitchell, Max and Zablah, Jenny E},
title = {Computed Tomography-Derived Normative Values of Right Ventricular Outflow Tract Structures in the Pediatric Population},
journal = {Pediatric Cardiology},
year = {2025},
doi = {10.1007/s00246-024-03456-2}
}
EUVIMED