Impact of 4D-Flow CMR Parameters on Functional Evaluation of Fontan Circulation

Lamia Ait Ali, Nicola Martini, Elisa Listo, Elisa Valenti, Julio Sotelo, Stefano Salvadori, Claudio Passino, Angelo Monteleone, Nicola Stagnaro, Gianluca Trocchio, Chiara Marrone, Francesca Raimondi und 2 weitere

Pediatric Cardiology · 2024-06 · 45 (5) · 998-1006

DOI: 10.1007/s00246-024-03446-4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pediatric Cardiology, online erschienen am 22.03.2024. Verfasst von Lamia Ait Ali und 13 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Clinical Physiology, National Research Council, Via Aurelia Sud, 54100, Massa, Pisa, Italy. aitlamia@ifc.cnr.it. Hauptthemen laut MEDLINE: Fontan Procedure, Heart Defects, Congenital, Exercise Test, Pulmonary Artery. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Consiglio Nazionale Delle Ricerche.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We sought to evaluate the potential clinical role of 4D-flow cardiac magnetic resonance (CMR)-derived energetics and flow parameters in a cohort of patients’ post-Fontan palliation. In patients with Fontan circulation who underwent 4D-Flow CMR, streamlines distribution was evaluated, as well a 4D-flow CMR-derived energetics parameters as kinetic energy (KE) and energy loss (EL) normalized by volume. EL/KE index as a marker of flow efficiency was also calculated. Cardiopulmonary exercise test (CPET) was also performed in a subgroup of patients. The population study included 55 patients (mean age 22 ± 11 years). The analysis of the streamlines revealed a preferential distribution of the right superior vena cava flow for the right pulmonary artery (62.5 ± 35.4%) and a mild preferential flow for the left pulmonary artery (52.3 ± 40.6%) of the inferior vena cave-pulmonary arteries (IVC-PA) conduit. Patients with heart failure (HF) presented lower IVC/PA-conduit flow (0.75 ± 0.5 vs 1.3 ± 0.5 l/min/m 2 , p = 0.004) and a higher mean flow-jet angle of the IVC-PA conduit (39.2 ± 22.8 vs 15.2 ± 8.9, p < 0.001) than the remaining patients. EL/KE index correlates inversely with VO 2 /kg/min: R : − 0.45, p = 0.01 peak, minute ventilation (VE) R : − 0.466, p < 0.01, maximal voluntary ventilation: R :0.44, p = 0.001 and positively with the physiological dead space to the tidal volume ratio (VD/VT) peak: R : 0.58, p < 0.01. From our data, lower blood flow in IVC/PA conduit and eccentric flow was associated with HF whereas higher EL/KE index was associated with reduced functional capacity and impaired lung function. Larger studies are needed to confirm our results and to further improve the prognostic role of the 4D-Flow CMR in this challenging population.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fontan ProcedureHeart Defects, CongenitalExercise TestPulmonary ArteryHumansFemaleMaleYoung AdultAdolescentAdultMagnetic Resonance Imaging, CineChildVena Cava, SuperiorBlood Flow VelocityHeart FailureVena Cava, Inferior

Stichwörter der Autor:innen

4D-flow CMRCardiac magnetic resonanceEnergy lossFontan flowsFontan palliation

Autor:innen und Institutionen

  • Institute of Clinical Physiology, National Research Council, Via Aurelia Sud, 54100, Massa, Pisa, Italy. aitlamia@ifc.cnr.it.
  • Gabriele Monasterio Foundation, Pisa, Massa, Italy. aitlamia@ifc.cnr.it.
  • Gabriele Monasterio Foundation, Pisa, Massa, Italy.
  • Azienda Ospedaliera ASL, 3-Ospedale Villascassi, Genoa, Italy.
  • Institute of Clinical Physiology, National Research Council, Via Aurelia Sud, 54100, Massa, Pisa, Italy.
  • Departamento de Informática, Universidad Técnica Federico Santa María, Santiago, Chile.

Förderung

  • Consiglio Nazionale Delle Ricerche

Zitieren

APA

Ait Ali, L., Martini, N., Listo, E., Valenti, E., Sotelo, J., Salvadori, S., Passino, C., Monteleone, A., Stagnaro, N., Trocchio, G., Marrone, C., Raimondi, F., Catapano, G., & Festa, P. (2024). Impact of 4D-Flow CMR Parameters on Functional Evaluation of Fontan Circulation. Pediatric Cardiology, 45(5), 998-1006. https://doi.org/10.1007/s00246-024-03446-4

Vancouver

Ait Ali L, Martini N, Listo E, Valenti E, Sotelo J, Salvadori S, et al. Impact of 4D-Flow CMR Parameters on Functional Evaluation of Fontan Circulation. Pediatric Cardiology. 2024;45(5):998-1006. doi:10.1007/s00246-024-03446-4

BibTeX
@article{AitAli2024,
  author = {Ait Ali, Lamia and Martini, Nicola and Listo, Elisa and Valenti, Elisa and Sotelo, Julio and Salvadori, Stefano and Passino, Claudio and Monteleone, Angelo and Stagnaro, Nicola and Trocchio, Gianluca and Marrone, Chiara and Raimondi, Francesca and Catapano, Giosuè and Festa, Pierluigi},
  title = {Impact of 4D-Flow CMR Parameters on Functional Evaluation of Fontan Circulation},
  journal = {Pediatric Cardiology},
  year = {2024},
  volume = {45},
  number = {5},
  pages = {998--1006},
  doi = {10.1007/s00246-024-03446-4}
}
Kostenlos starten →