EUVIMEDEUVIMED entdecken
Crossref

Photon-counting computed tomography improves interobserver agreement in the evaluation of failed stapes surgery

Simon Beatty, Kalen Riley, Nicholas Deep, Nicholas Koontz iD

Neuroradiology · 16.11.2026

DOI: 10.1007/s00234-026-04268-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Neuroradiology, online erschienen am 16.11.2026. Verfasst von Simon Beatty und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otolaryngology-Head and Neck Surgery, Mayo Clinic Arizona, Phoenix, USA. Die Arbeit nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Failed stapes surgery presents a diagnostic challenge requiring high-resolution imaging to guide revision. Photon-counting CT (PCCT) offers improved spatial resolution and reduced noise compared with conventional energy-integrating detector CT (EID-CT). This study compared PCCT and EID-CT for identifying etiologies of failed primary stapes surgery, with emphasis on diagnostic accuracy, interobserver agreement, and interpreter confidence.

Methods

In this retrospective study, 38 patients with failed primary stapes surgery who underwent successful revision surgery and pre-revision CT were included; 18 underwent PCCT and 20 underwent EID-CT. Three expert reviewers independently determined the cause of surgical failure using intraoperative findings at revision as the reference standard. Diagnostic accuracy, interobserver agreement (Fleiss kappa), and reader confidence were compared between modalities.

Results

Overall interobserver agreement was higher with PCCT (κ = 0.75; 95% CI, 0.60–0.90) than EID-CT (κ = 0.44; 95% CI, 0.30–0.59), with non-overlapping confidence intervals for overall agreement and ossicular discontinuity. Consensus diagnostic accuracy did not significantly differ between modalities (88.9% PCCT vs. 85.0% EID-CT; p = 1.00), nor did interpreter confidence (4.33 vs. 4.17; p = 0.29).

Conclusion

In this small cohort, PCCT demonstrated higher interobserver agreement than EID-CT without statistically significant differences in diagnostic accuracy or reader confidence, suggesting more reproducible assessment of failed stapes surgery.

Schlagwörter

Stichwörter der Autor:innen

Energy-integrating detector computed tomographyOtosclerosisPhoton-counting computed tomographyStapedotomyStapes surgeryTemporal bone

Autor:innen und Institutionen

  • Department of Otolaryngology-Head and Neck Surgery, Mayo Clinic Arizona, Phoenix, USA.
  • Department of Radiology, Mayo Clinic Arizona, Phoenix, USA.
  • Department of Radiology, Mayo Clinic Arizona, Phoenix, USA. koontz.nicholas@mayo.edu.

ORCID-Profile: Nicholas Koontz

Zitieren

APA

Beatty, S., Riley, K., Deep, N., & Koontz, N. (2026). Photon-counting computed tomography improves interobserver agreement in the evaluation of failed stapes surgery. Neuroradiology. https://doi.org/10.1007/s00234-026-04268-2

Vancouver

Beatty S, Riley K, Deep N, Koontz N. Photon-counting computed tomography improves interobserver agreement in the evaluation of failed stapes surgery. Neuroradiology. 2026. doi:10.1007/s00234-026-04268-2

BibTeX
@article{Beatty2026,
  author = {Beatty, Simon and Riley, Kalen and Deep, Nicholas and Koontz, Nicholas},
  title = {Photon-counting computed tomography improves interobserver agreement in the evaluation of failed stapes surgery},
  journal = {Neuroradiology},
  year = {2026},
  doi = {10.1007/s00234-026-04268-2}
}
Kostenlos starten →