Safety profile of a location-tailored short DAPT protocol for intracranial aneurysms treated with flow diversion
Neuroradiology · 05.11.2026
DOI: 10.1007/s00234-026-04236-w ↗Kurz gefasst
Studienprotokoll in der Zeitschrift Neuroradiology, online erschienen am 05.11.2026. Verfasst von Giulia Platania und 8 weiteren Autor:innen. Beteiligte Einrichtung: Neuroradiology Unit, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy. Die Arbeit nennt 22 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: There is no consensus on antiplatelet management after flow-diverter (FD) deployment. While prolonged dual antiplatelet therapy (DAPT) remains common, this approach carries haemorrhagic risks. We evaluated the safety of a short, location-tailored DAPT protocol for patients treated with FDs for intracranial aneurysms. METHODS: We retrospectively reviewed consecutive patients undergoing elective FD treatment for intracranial aneurysms in our department. Patients followed a post-procedural DAPT protocol tailored to target vessel location: 1-month DAPT for internal carotid (ICA) and vertebral arteries (VA), and 3-month for other locations, followed by single antiplatelet therapy (SAPT). Periprocedural and delayed thromboembolic and haemorrhagic complications were assessed. RESULTS: Seventy-five patients with 82 aneurysms were included. Median DAPT duration was 43.0 days (IQR: 34.0-92.0) for ICA/VA, and 93.5 days (IQR: 90.7-99.0) for other locations. Periprocedural symptomatic neurological thromboembolic complications occurred in 1/82 (1.2%) of procedures, while no periprocedural neurological haemorrhagic complications occurred. Delayed symptomatic neurological thromboembolic complications occurred in 1/75 patients (1.3%) during DAPT, 2/75 (2.7%) after DAPT discontinuation, 1/55 (1.8%) after SAPT discontinuation. Delayed neurological haemorrhagic complications were 0%; other delayed haemorrhagic complications occurred in 2/75 patients (2.7%) during DAPT and 1/75 (1.3%) during SAPT. Adequate aneurysm occlusion was achieved in 72.9% of cases at angiographic follow-up (median 205.5 days, IQR: 183.8-239.0). At the last clinical follow-up (median 707.0 days, IQR: 389.5-998.5), overall mortality was 0% and permanent morbidity was 2.7%. CONCLUSIONS: A short vessel-tailored DAPT protocol is a safe and feasible management strategy for intracranial FD treatments, demonstrating low thromboembolic and haemorrhagic risks.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Neuroradiology Unit, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy.
- Neurosurgery Unit, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy.
- Specialization School in Neurosurgery, University of Milan, Milan, Italy.
- Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy.
- Neuroradiology Unit, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy. giorgio.conte@policlinico.mi.it.
- Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy. giorgio.conte@policlinico.mi.it.
Zitieren
APA
Platania, G., Caschera, L., Modello, B., Bertani, G. A., Fiore, G., Tozzi, A., Locatelli, M., Triulzi, F., & Conte, G. (2026). Safety profile of a location-tailored short DAPT protocol for intracranial aneurysms treated with flow diversion. Neuroradiology. https://doi.org/10.1007/s00234-026-04236-w
Vancouver
Platania G, Caschera L, Modello B, Bertani GA, Fiore G, Tozzi A, et al. Safety profile of a location-tailored short DAPT protocol for intracranial aneurysms treated with flow diversion. Neuroradiology. 2026. doi:10.1007/s00234-026-04236-w
BibTeX
@article{Platania2026,
author = {Platania, Giulia and Caschera, Luca and Modello, Beatrice and Bertani, Giulio Andrea and Fiore, Giorgio and Tozzi, Alessandro and Locatelli, Marco and Triulzi, Fabio and Conte, Giorgio},
title = {Safety profile of a location-tailored short DAPT protocol for intracranial aneurysms treated with flow diversion},
journal = {Neuroradiology},
year = {2026},
doi = {10.1007/s00234-026-04236-w}
}
EUVIMED