EUVIMEDEUVIMED entdecken
Crossref

Super-resolution deep learning reconstruction for brain fluid-attenuated inversion recovery: image quality and white matter hyperintensity volume analysis

Jae-Kyun Ryu, Hei-Jung Jang, Chuluunbaatar Otgonbaatar, Junhyung Kim, Seongkyu Jeon, Hackjoon Shim, Hyunjung Kim, Jin Woo Kim

Neuroradiology · 06.07.2026

DOI: 10.1007/s00234-026-04104-7 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Neuroradiology, online erschienen am 06.07.2026. Verfasst von Jae-Kyun Ryu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Medical Imaging AI Research Center, Canon Medical Systems Korea, Seoul, South Korea. Die Arbeit nennt 23 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To evaluate whether super-resolution deep learning reconstruction (SR-DLR) improves two-dimensional (2D) brain fluid-attenuated inversion recovery (FLAIR) image quality while preserving automated white matter hyperintensity (WMH) volumetry, compared with Gaussian-filtered reconstruction (GA) and denoising DLR (dDLR). METHODS: Thirty-six healthy volunteers underwent 3T axial 2D FLAIR. Images were reconstructed using GA, dDLR, and SR-DLR (twofold in-plane upscaling). Quantitative metrics (noise, SNR, CNR, sharpness) were measured in standardized regions of interest. Two radiologists independently scored qualitative image quality. In a WMH-positive subgroup, WMH volumes were obtained using a transformer-based U-Net segmentation model on GA, dDLR, SR-DLR, and a high-resolution acquisition (HR-dDLR). Quantitative image-quality metrics were compared using one-way ANOVA, WMH volumes using paired t-tests, and interobserver agreement using weighted kappa. RESULTS: SR-DLR demonstrated the lowest image noise and the highest SNR, CNR, and sharpness compared with GA and dDLR (all p < 0.001). Qualitative scores for noise, sharpness, and overall image quality were significantly higher for SR-DLR (p < 0.001), with perfect inter-observer agreement for sharpness and overall quality. Mean WMH volumes did not differ significantly across reconstructions, and SR-DLR volumes closely matched those of HR-dDLR. CONCLUSION: SR-DLR substantially improves 2D brain FLAIR image quality at 3T by reducing noise and increasing SNR, CNR, and sharpness while preserving WMH volumetry consistent with high-resolution reference standards.

Schlagwörter

Stichwörter der Autor:innen

Deep learning reconstructionFluid-attenuated inversion recovery (FLAIR)Super-resolutionWhite matter hyperintensity (WMH)

Autor:innen und Institutionen

  • Medical Imaging AI Research Center, Canon Medical Systems Korea, Seoul, South Korea.
  • Magnetic Resonance Business Unit, Canon Medical Systems Korea, Seoul, South Korea.
  • ConnectAI Research Center, Yonsei University College of Medicine, Seoul, South Korea.
  • Department of Radiology, Wonju Severance Christian Hospital, Wonju, South Korea.
  • Department of Radiology, Wonju Severance Christian Hospital, Wonju, South Korea. sunny-cocktail@hanmail.net.

Zitieren

APA

Ryu, J. K., Jang, H. J., Otgonbaatar, C., Kim, J., Jeon, S., Shim, H., Kim, H., & Kim, J. W. (2026). Super-resolution deep learning reconstruction for brain fluid-attenuated inversion recovery: image quality and white matter hyperintensity volume analysis. Neuroradiology. https://doi.org/10.1007/s00234-026-04104-7

Vancouver

Ryu JK, Jang HJ, Otgonbaatar C, Kim J, Jeon S, Shim H, et al. Super-resolution deep learning reconstruction for brain fluid-attenuated inversion recovery: image quality and white matter hyperintensity volume analysis. Neuroradiology. 2026. doi:10.1007/s00234-026-04104-7

BibTeX
@article{Ryu2026,
  author = {Ryu, Jae-Kyun and Jang, Hei-Jung and Otgonbaatar, Chuluunbaatar and Kim, Junhyung and Jeon, Seongkyu and Shim, Hackjoon and Kim, Hyunjung and Kim, Jin Woo},
  title = {Super-resolution deep learning reconstruction for brain fluid-attenuated inversion recovery: image quality and white matter hyperintensity volume analysis},
  journal = {Neuroradiology},
  year = {2026},
  doi = {10.1007/s00234-026-04104-7}
}
Kostenlos starten →