EUVIMEDEUVIMED entdecken
Vergleichsstudie

Machine learning–based integration and comparison of ADC map radiomics with conventional imaging markers for cholesteatoma diagnosis

Ramazan Orkun Onder, Serdar Aslan, Tümay Bekci, Alptekin Tosun, Erol Egrioglu

Neuroradiology · 2026

DOI: 10.1007/s00234-026-04066-w ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Neuroradiology, 2026. Verfasst von Ramazan Orkun Onder und 4 weiteren Autor:innen. Beteiligte Einrichtung: Giresun University, Giresun, Turkey. orkunonder535@gmail.com. Hauptthemen laut MEDLINE: Radiomics, Machine Learning, Cholesteatoma, Middle Ear, Tomography, X-Ray Computed. Die Arbeit nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To compare the diagnostic performance of apparent diffusion coefficient (ADC) map-based radiomics with conventional CT and DWI for differentiating cholesteatoma from non-cholesteatomatous middle ear lesions and to evaluate the incremental value of their integration using machine learning (ML). METHODS: This retrospective single-centre study included a derivation cohort of 51 histopathologically confirmed lesions (23 cholesteatomas, 28 non-cholesteatomatous lesions) and a held-out internal validation cohort of 20 lesions (9 cholesteatomas, 11 non-cholesteatomatous lesions). Conventional imaging variables included CT attenuation, visually assessed diffusion restriction on DWI, and quantitative ADC. ADC maps were manually segmented, and 122 radiomic features were extracted. Predictive modelling used 3-fold cross-validation with fold-specific feature screening, normalisation, feature selection, and classifier selection. Final combined-model reproducibility was assessed using intraclass correlation coefficients. RESULTS: Compared with non-cholesteatomatous lesions, cholesteatomas showed higher CT attenuation, more frequent diffusion restriction, and lower ADC values (all p < 0.05). The final combined model incorporated quantitative ADC, GLRLM low gray-level run emphasis, and first-order coefficient of variation. Among the evaluated classifiers, a three-layer artificial neural network performed best for the combined dataset. In the held-out internal validation cohort, the combined radiology-radiomics model showed the highest diagnostic performance, with 95.0% accuracy, 100% sensitivity, 90.9% specificity, and an AUC of 0.951. CONCLUSION: ADC map-based radiomics may provide complementary microstructural information beyond conventional imaging. In this internally validated exploratory study, combining quantitative ADC with selected ADC-derived radiomic features improved discrimination of cholesteatoma from non-cholesteatomatous middle ear lesions, although external validation is required before clinical implementation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RadiomicsMachine LearningCholesteatoma, Middle EarTomography, X-Ray ComputedDiffusion Magnetic Resonance ImagingHumansRetrospective StudiesFemaleMaleReproducibility of ResultsMiddle AgedAdultDiagnosis, DifferentialSensitivity and SpecificityAgedAdolescent

Stichwörter der Autor:innen

Apparent diffusion coefficientCholesteatomaDiffusion-weighted imagingMachine learningRadiomics

Autor:innen und Institutionen

  • Giresun University, Giresun, Turkey. orkunonder535@gmail.com.
  • Tosya State Hospital, Kastamonu, Turkey. orkunonder535@gmail.com.
  • Giresun University, Giresun, Turkey.
  • Istanbul Medipol University, Istanbul, Turkey.
  • Trabzon University, Trabzon, Turkey.

Zitieren

APA

Onder, R. O., Aslan, S., Bekci, T., Tosun, A., & Egrioglu, E. (2026). Machine learning–based integration and comparison of ADC map radiomics with conventional imaging markers for cholesteatoma diagnosis. Neuroradiology. https://doi.org/10.1007/s00234-026-04066-w

Vancouver

Onder RO, Aslan S, Bekci T, Tosun A, Egrioglu E. Machine learning–based integration and comparison of ADC map radiomics with conventional imaging markers for cholesteatoma diagnosis. Neuroradiology. 2026. doi:10.1007/s00234-026-04066-w

BibTeX
@article{Onder2026,
  author = {Onder, Ramazan Orkun and Aslan, Serdar and Bekci, Tümay and Tosun, Alptekin and Egrioglu, Erol},
  title = {Machine learning–based integration and comparison of ADC map radiomics with conventional imaging markers for cholesteatoma diagnosis},
  journal = {Neuroradiology},
  year = {2026},
  doi = {10.1007/s00234-026-04066-w}
}
Kostenlos starten →