EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Duplex ultrasound in severe carotid stenosis: diagnostic performance for differentiating near-occlusion subtypes from conventional high-grade stenosis

Corinne Inauen, Isabelle Barnaure, Lisa Herzog, Winston Schegg, Giuseppe Esposito, Zsolt Kulcsar, Stefan Yu Bögli, Andreas Luft, Elias Johansson, Susanne Wegener

Neuroradiology · 2026

DOI: 10.1007/s00234-026-04005-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Neuroradiology, 2026. Verfasst von Corinne Inauen und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurology, University Hospital Zurich, University of Zurich, Zurich, Switzerland. corinne.inauen@usz.ch. Hauptthemen laut MEDLINE: Carotid Stenosis, Ultrasonography, Doppler, Duplex. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: The Swiss National Science Foundation (SNSF), The University of Zurich Clinical Research Priority Program (CRPP) Stroke.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Carotid near-occlusion (CNO) is a subtype of severe carotid stenosis characterized by partial or complete distal internal carotid artery (ICA) collapse. Its diagnosis currently relies on angiographic imaging, and no validated duplex ultrasound (DUS) criteria exist. We aimed to assess the utility of DUS in distinguishing conventional high-grade stenosis (HGS), CNO without, and CNO with full collapse. METHODS: We retrospectively included patients with > 80% NASCET stenosis on DUS (2012-2021) who underwent CTA, MRA, or DSA within 3 months. DUS parameters were compared across groups defined by angiographic classification using uni- and multivariable analyses. RESULTS: Among 78 patients, 21 had HGS, 34 CNO without, and 23 CNO with full collapse. DUS agreed with angiographic classification in 54%, with CNO without full collapse often misclassified as HGS (85%). Velocity-based DUS metrics could not reliably distinguish CNO without full collapse from HGS. However, CNO with full collapse was distinguishable based on stenotic and distal peak-systolic and end-diastolic velocities and derived ratios (AUCs 0.70-0.76). Diameter-based metrics distinguished HGS from both CNO types: distal ICA < 3.15 mm (AUC 0.79) and ICA/ECA ratio < 0.98 (AUC 0.78). Multivariable models increased discriminatory performance (AUC 0.82). CONCLUSION: Velocity-based DUS metrics cannot reliably distinguish HGS from CNO without full collapse, representing a key clinical challenge. Although DUS-derived metrics were associated with angiographically defined CNO with full collapse, overall diagnostic gain was modest and additional imaging will often remain necessary. Nevertheless, DUS remains useful for follow-up, as hemodynamic changes may indicate evolving distal collapse.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Carotid StenosisUltrasonography, Doppler, DuplexHumansRetrospective StudiesFemaleMaleDiagnosis, DifferentialAgedSeverity of Illness IndexMagnetic Resonance Angiography

Stichwörter der Autor:innen

Carotid near-occlusionColour duplex ultrasoundHemodynamic assessmentHigh-grade carotid stenosisNASCET criteria

Autor:innen und Institutionen

  • Department of Neurology, University Hospital Zurich, University of Zurich, Zurich, Switzerland. corinne.inauen@usz.ch.
  • Clinical Neuroscience Center, University Hospital Zurich, University of Zurich, Zurich, Switzerland. corinne.inauen@usz.ch.
  • Clinical Neuroscience Center, University Hospital Zurich, University of Zurich, Zurich, Switzerland.
  • Department of Neuroradiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland.
  • Department of Neurology, University Hospital Zurich, University of Zurich, Zurich, Switzerland.
  • Department of Neurosurgery, University Hospital Zurich, University of Zurich, Zurich, Switzerland.

Förderung

  • The Swiss National Science Foundation (SNSF)
  • The University of Zurich Clinical Research Priority Program (CRPP) Stroke

Zitieren

APA

Inauen, C., Barnaure, I., Herzog, L., Schegg, W., Esposito, G., Kulcsar, Z., Bögli, S. Y., Luft, A., Johansson, E., & Wegener, S. (2026). Duplex ultrasound in severe carotid stenosis: diagnostic performance for differentiating near-occlusion subtypes from conventional high-grade stenosis. Neuroradiology. https://doi.org/10.1007/s00234-026-04005-9

Vancouver

Inauen C, Barnaure I, Herzog L, Schegg W, Esposito G, Kulcsar Z, et al. Duplex ultrasound in severe carotid stenosis: diagnostic performance for differentiating near-occlusion subtypes from conventional high-grade stenosis. Neuroradiology. 2026. doi:10.1007/s00234-026-04005-9

BibTeX
@article{Inauen2026,
  author = {Inauen, Corinne and Barnaure, Isabelle and Herzog, Lisa and Schegg, Winston and Esposito, Giuseppe and Kulcsar, Zsolt and Bögli, Stefan Yu and Luft, Andreas and Johansson, Elias and Wegener, Susanne},
  title = {Duplex ultrasound in severe carotid stenosis: diagnostic performance for differentiating near-occlusion subtypes from conventional high-grade stenosis},
  journal = {Neuroradiology},
  year = {2026},
  doi = {10.1007/s00234-026-04005-9}
}