Improved CTA imaging for stroke evaluation – deep learning and iterative reconstruction comparative study
Neuroradiology · 2025
DOI: 10.1007/s00234-025-03733-8 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Neuroradiology, 2025. Verfasst von Michal Pula und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of General Radiology, Interventional Radiology and Neuroradiology, Wroclaw Medical University Hospital, Wrocław, Poland. michal.pula97@gma…. Hauptthemen laut MEDLINE: Deep Learning, Computed Tomography Angiography, Radiographic Image Interpretation, Computer-Assisted, Cerebral Angiography. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben. Gefördert von: Wroclaw Medical University.
Themen: Schlaganfall
Abstract (Originalsprache)
PURPOSE: This study compares a novel reconstruction algorithm deep learning-based image reconstruction (DLIR) and adaptive statistical iterative reconstruction-Veo (ASIR-V) for CTA in acute ischemic stroke (AIS) patients, emphasizing DLIR's potential to improve diagnostic accuracy and visualization of large vessel occlusion. METHODS: This study retrospectively assessed 108 consecutive AIS-suspected emergency department patients (mean age 72.3 years +/- 17) who underwent head and neck CTA with DLIR and ASIR-V reconstructions. The analysis compared the impact of DLIR versus ASIR-V on image quality, assessing signal-to-noise (SNR), contrast-to-noise ratios (CNR), and contrast-enhanced arteries homogeneity computed on mean HU values and SD in six regions of interest located in head and neck including three arteries. RESULTS: The DLIR reconstruction allowed for significant SNR and CNR improvement, with the largest SNR distinction obtained in the common carotid artery (52.29% increased SNR) and white matter of the pons (63.98% increased SNR). Among the three regions subject to CNR evaluation DLIR yielded superiority in the neck and posterior cerebral fossa while ASIR-V accounted for higher CNR in the medial cerebral fossa (MCF). Additionally, DLIR-reconstructed images achieved a 21.10% improvement in arterial homogeneity, enhancing the visualization of potential occlusion. CONCLUSION: DLIR yields superior image quality of the contrast-enhanced head and neck structures in CTA, providing artery images with increased homogeneity and potentially allowing for more proficient occlusion evaluation specifically in the area of the posterior cerebral fossa. However, this technique faces challenges in the visualization of MCF.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of General Radiology, Interventional Radiology and Neuroradiology, Wroclaw Medical University Hospital, Wrocław, Poland. michal.pula97@gmail.com.
- Wroclaw Medical University, Wrocław, Poland.
- 4th Military Clinical Hospital in Wroclaw, Wroclaw, Poland.
- Department of General and Interventional Radiology and Neuroradiology, Department of Radiology, Wroclaw Medical University, Wrocław, Poland.
Förderung
- Wroclaw Medical University
Zitieren
APA
Pula, M., Kucharczyk, E., Piersiak, M., Ziomek, M., Zdanowicz-Ratajczyk, A., & Guzinski, M. (2025). Improved CTA imaging for stroke evaluation – deep learning and iterative reconstruction comparative study. Neuroradiology. https://doi.org/10.1007/s00234-025-03733-8
Vancouver
Pula M, Kucharczyk E, Piersiak M, Ziomek M, Zdanowicz-Ratajczyk A, Guzinski M. Improved CTA imaging for stroke evaluation – deep learning and iterative reconstruction comparative study. Neuroradiology. 2025. doi:10.1007/s00234-025-03733-8
BibTeX
@article{Pula2025,
author = {Pula, Michal and Kucharczyk, Emilia and Piersiak, Marcin and Ziomek, Maciej and Zdanowicz-Ratajczyk, Agata and Guzinski, Maciej},
title = {Improved CTA imaging for stroke evaluation – deep learning and iterative reconstruction comparative study},
journal = {Neuroradiology},
year = {2025},
doi = {10.1007/s00234-025-03733-8}
}
EUVIMED