Vergleichsstudie in der Zeitschrift Neuroradiology, 2025. Verfasst von Zhen-Zhen Liu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, the Third Affiliated Hospital of Sun Yat-Sen University, No. 600 Tianhe Road, Guangzhou, 510630, People's Republic of China. Hauptthemen laut MEDLINE: Migraine Disorders, White Matter, Magnetic Resonance Imaging. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 41 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Basic and Applied Basic Research Foundation of Guangdong Province.
Abstract (Originalsprache)
OBJECTIVE: Young migraine patients often present with white matter hyperintensities (WMHs) on magnetic resonance imaging (MRI). This study aimed to analyze whether synthetic (Syn) T2-FLAIR and Syn double inversion recovery (DIR) can reveal WMHs more clearly and sensitively than conventional T2-FLAIR. MATERIALS AND METHODS: Conventional MRI and Syn MRI data from 50 young migraine patients were analyzed prospectively. WMHs in each anatomical region (periventricular, deep white matter, and juxtacortical) were recorded separately. The differences in the clarity of lesion boundaries and the number of lesions displayed in the three sequences in the same anatomical region were analyzed. RESULTS: A total of 80 (periventricular area, 15; deep white matter, 31; juxtacortical area, 34), 163 (17, 50, 96), and 134 (18, 42, 74) lesions were observed with conventional T2-FLAIR, Syn T2-FLAIR, and Syn DIR, respectively. Syn T2-FLAIR and Syn DIR can show lesions more clearly than conventional T2-FLAIR (all P < 0.001). There was no significant difference in the number of lesions observed in the periventricular white matter among the three sequences (P = 0.159, 0.083, 0.322). Syn T2-FLAIR and Syn DIR can detect more lesions in the deep white matter than conventional T2-FLAIR (P < 0.001, P = 0.006). Syn T2-FLAIR revealed more lesions in the juxtacortical white matter than Syn DIR and conventional T2-FLAIR imaging (all P < 0.001), and conventional T2-FLAIR revealed the fewest lesions (P < 0.001). CONCLUSION: Syn T2-FLAIR and Syn DIR sequences can clearly and sensitively detect WMHs, especially in deep and juxtacortical white matter areas.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, the Third Affiliated Hospital of Sun Yat-Sen University, No. 600 Tianhe Road, Guangzhou, 510630, People's Republic of China.
- Department of Orthopedics, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, People's Republic of China.
- Department of Radiology, the People's Hospital of Dabu County, Meizhou, People's Republic of China.
- Department of Radiology, the Third Affiliated Hospital of Sun Yat-Sen University, No. 600 Tianhe Road, Guangzhou, 510630, People's Republic of China. zhangj553@mail.sysu.edu.cn.
- Department of Radiology, the Third Affiliated Hospital of Sun Yat-Sen University, No. 600 Tianhe Road, Guangzhou, 510630, People's Republic of China. guoruomi86@mail.sysu.edu.cn.
Förderung
- National Natural Science Foundation of China
- Basic and Applied Basic Research Foundation of Guangdong Province
Zitieren
APA
Liu, Z. Z., Yu, H. Y., Li, Y. H., Zhang, Z. C., Zhao, B. L., Zhang, J., & Guo, R. M. (2025). Comparison of Syn T2-FLAIR and Syn DIR with conventional T2-FLAIR in displaying white matter hyperintensities in migraine patients. Neuroradiology. https://doi.org/10.1007/s00234-024-03477-x
Vancouver
Liu ZZ, Yu HY, Li YH, Zhang ZC, Zhao BL, Zhang J, et al. Comparison of Syn T2-FLAIR and Syn DIR with conventional T2-FLAIR in displaying white matter hyperintensities in migraine patients. Neuroradiology. 2025. doi:10.1007/s00234-024-03477-x
BibTeX
@article{Liu2025,
author = {Liu, Zhen-Zhen and Yu, Hai-Yang and Li, Yuan-Hui and Zhang, Zhi-Cheng and Zhao, Bin-Liang and Zhang, Jie and Guo, Ruo-Mi},
title = {Comparison of Syn T2-FLAIR and Syn DIR with conventional T2-FLAIR in displaying white matter hyperintensities in migraine patients},
journal = {Neuroradiology},
year = {2025},
doi = {10.1007/s00234-024-03477-x}
}
EUVIMED