EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluation of 3D T1-weighted spoiled gradient echo MR image quality using artificial intelligence image reconstruction techniques in the pediatric brain

Usha D Nagaraj, Jonathan R Dillman, Jean A Tkach, Joshua S Greer, James L Leach

Neuroradiology · 2024

DOI: 10.1007/s00234-024-03417-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Neuroradiology, 2024. Verfasst von Usha D Nagaraj und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Medical Imaging, Cincinnati Children's Hospital Medical Center, 3333 Burnet Avenue, Cincinnati, OH, 45229-3026, USA. usha…. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Magnetic Resonance Imaging, Artificial Intelligence. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Cincinnati Children's Hospital Medical Center, Cincinnati Children’s Hospital Medical Center.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To assess image quality and diagnostic confidence of 3D T1-weighted spoiled gradient echo (SPGR) MRI using artificial intelligence (AI) reconstruction. Materials and methods This prospective, IRB-approved study enrolled 50 pediatric patients (mean age = 11.8 ± 3.1 years) undergoing clinical brain MRI. In addition to standard of care (SOC) compressed SENSE (CS = 2.5), 3D T1-weighted SPGR images were obtained with higher CS acceleration factors (5 and 8) to evaluate the ability of AI reconstruction to improve image quality and reduce scan time. Images were reviewed independently on dedicated research PACS workstations by two neuroradiologists. Quantitative analysis of signal intensities to calculate apparent grey and white matter signal to noise (aSNR) and grey-white matter apparent contrast to noise ratios (aCNR) was performed.

Results

AI improved overall image quality compared to standard CS reconstruction in 35% (35/100) of evaluations in CS = 2.5 (average scan time = 221 ± 6.9 s), 100% (46/46) of CS = 5 (average scan time = 113.3 ± 4.6 s) and 94% (47/50) of CS = 8 (average scan time = 74.1 ± 0.01 s). Quantitative analysis revealed significantly higher grey matter aSNR, white matter aSNR and grey-white matter aCNR with AI reconstruction compared to standard reconstruction for CS 5 and 8 (all p-values < 0.001), however not for CS 2.5.

Conclusions

AI reconstruction improved overall image quality and gray-white matter qualitative and quantitative aSNR and aCNR in highly accelerated (CS = 5 and 8) 3D T1W SPGR images in the majority of pediatric patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Imaging, Three-DimensionalMagnetic Resonance ImagingArtificial IntelligenceHumansChildMaleFemaleProspective StudiesImage Interpretation, Computer-AssistedAdolescentSignal-To-Noise RatioBrainBrain DiseasesChild, Preschool

Stichwörter der Autor:innen

Artificial intelligenceBrain MRICompressed sensingPediatrics

Autor:innen und Institutionen

  • Department of Radiology and Medical Imaging, Cincinnati Children's Hospital Medical Center, 3333 Burnet Avenue, Cincinnati, OH, 45229-3026, USA. usha.nagaraj@cchmc.org.
  • Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA. usha.nagaraj@cchmc.org.
  • Department of Radiology and Medical Imaging, Cincinnati Children's Hospital Medical Center, 3333 Burnet Avenue, Cincinnati, OH, 45229-3026, USA.
  • Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA.
  • Philips Healthcare, Cincinnati, OH, USA.

Förderung

  • Cincinnati Children's Hospital Medical Center
  • Cincinnati Children’s Hospital Medical Center

Zitieren

APA

Nagaraj, U. D., Dillman, J. R., Tkach, J. A., Greer, J. S., & Leach, J. L. (2024). Evaluation of 3D T1-weighted spoiled gradient echo MR image quality using artificial intelligence image reconstruction techniques in the pediatric brain. Neuroradiology. https://doi.org/10.1007/s00234-024-03417-9

Vancouver

Nagaraj UD, Dillman JR, Tkach JA, Greer JS, Leach JL. Evaluation of 3D T1-weighted spoiled gradient echo MR image quality using artificial intelligence image reconstruction techniques in the pediatric brain. Neuroradiology. 2024. doi:10.1007/s00234-024-03417-9

BibTeX
@article{Nagaraj2024,
  author = {Nagaraj, Usha D and Dillman, Jonathan R and Tkach, Jean A and Greer, Joshua S and Leach, James L},
  title = {Evaluation of 3D T1-weighted spoiled gradient echo MR image quality using artificial intelligence image reconstruction techniques in the pediatric brain},
  journal = {Neuroradiology},
  year = {2024},
  doi = {10.1007/s00234-024-03417-9}
}
Kostenlos starten →