Comparison of 1.5 T and 3 T magnetic resonance angiography for detecting cerebral aneurysms using deep learning-based computer-assisted detection software
Neuroradiology · 2023-10 · 65 (10) · 1473-1482
DOI: 10.1007/s00234-023-03216-8 ↗Kurz gefasst
Fachartikel in der Zeitschrift Neuroradiology, online erschienen am 30.08.2023. Verfasst von Taku Tajima und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, International University of Health and Welfare Mita Hospital, 1-4-3 Mita, Minato-Ku, Tokyo, 108-8329, Japan. Hauptthemen laut MEDLINE: Intracranial Aneurysm, Deep Learning. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 19 Literaturangaben. Gefördert von: Canon Medical Systems Corporation.
Abstract (Originalsprache)
PURPOSE: To compare the diagnostic performance of 1.5 T versus 3 T magnetic resonance angiography (MRA) for detecting cerebral aneurysms with clinically available deep learning-based computer-assisted detection software (EIRL aneurysm® [EIRL_an]), which has been approved by the Japanese Pharmaceuticals and Medical Devices Agency. We also sought to analyze the causes of potential false positives. METHODS: In this single-center, retrospective study, we evaluated the MRA scans of 90 patients who underwent head MRA (1.5 T and 3 T in 45 patients each) in clinical practice. Overall, 51 patients had 70 aneurysms. We used MRI from a vendor not included in the dataset used to create the EIRL_an algorithm. Two radiologists determined the ground truth, the accuracy of the candidates noted by EIRL_an, and the causes of false positives. The sensitivity, number of false positives per case (FPs/case), and the causes of false positives were compared between 1.5 T and 3 T MRA. Pearson's χ2 test, Fisher's exact test, and the Mann‒Whitney U test were used for the statistical analyses as appropriate. RESULTS: The sensitivity was high for 1.5 T and 3 T MRA (0.875‒1), but the number of FPs/case was significantly higher with 3 T MRA (1.511 vs. 2.578, p < 0.001). The most common causes of false positives (descending order) were the origin/bifurcation of vessels/branches, flow-related artifacts, and atherosclerosis and were similar between 1.5 T and 3 T MRA. CONCLUSION: EIRL_an detected significantly more false-positive lesions with 3 T than with 1.5 T MRA in this external validation study. Our data may help physicians with limited experience with MRA to correctly diagnose aneurysms using EIRL_an.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, International University of Health and Welfare Mita Hospital, 1-4-3 Mita, Minato-Ku, Tokyo, 108-8329, Japan.
- Department of Radiology, International University of Health and Welfare Narita Hospital, 852 Hatakeda, Narita, Chiba, 286-0124, Japan.
- Department of Radiology, The Institute of Medical Science, The University of Tokyo, 4-6-1 Shirokanedai, Minato-Ku, Tokyo, 108-8639, Japan.
- Department of Radiology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-Ku, Tokyo, 113-0033, Japan.
- International University of Health and Welfare, 2600-1 Kitakanamaru, Otawara, Tochigi, 324-8501, Japan.
- Department of Radiology, International University of Health and Welfare Narita Hospital, 852 Hatakeda, Narita, Chiba, 286-0124, Japan. kiryu-tky@umin.ac.jp.
Förderung
- Canon Medical Systems Corporation
Zitieren
APA
Tajima, T., Akai, H., Yasaka, K., Kunimatsu, A., Yoshioka, N., Akahane, M., Ohtomo, K., Abe, O., & Kiryu, S. (2023). Comparison of 1.5 T and 3 T magnetic resonance angiography for detecting cerebral aneurysms using deep learning-based computer-assisted detection software. Neuroradiology, 65(10), 1473-1482. https://doi.org/10.1007/s00234-023-03216-8
Vancouver
Tajima T, Akai H, Yasaka K, Kunimatsu A, Yoshioka N, Akahane M, et al. Comparison of 1.5 T and 3 T magnetic resonance angiography for detecting cerebral aneurysms using deep learning-based computer-assisted detection software. Neuroradiology. 2023;65(10):1473-1482. doi:10.1007/s00234-023-03216-8
BibTeX
@article{Tajima2023,
author = {Tajima, Taku and Akai, Hiroyuki and Yasaka, Koichiro and Kunimatsu, Akira and Yoshioka, Naoki and Akahane, Masaaki and Ohtomo, Kuni and Abe, Osamu and Kiryu, Shigeru},
title = {Comparison of 1.5 T and 3 T magnetic resonance angiography for detecting cerebral aneurysms using deep learning-based computer-assisted detection software},
journal = {Neuroradiology},
year = {2023},
volume = {65},
number = {10},
pages = {1473--1482},
doi = {10.1007/s00234-023-03216-8}
}
EUVIMED