EUVIMEDEUVIMED entdecken
Crossref

Feasibility of 100 kV Low-voltage Bone Mineral Density Measurement with Quantitative CT: Phantom and Clinical Research

Yali Li iD, Dan Jin, Yan Zhang, Mengze Zhang, Zhen Qian, Chenyu Jiang, Ming Ni, Suwei Liu, Huishu Yuan

Calcified Tissue International · 2025

DOI: 10.1007/s00223-025-01393-7 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Calcified Tissue International, 2025. Verfasst von Yali Li und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Peking University Third Hospital, 49 Huayuan N Rd, Haidian, Beijing, 100191, China. Hauptthemen laut MEDLINE: Bone Density, Tomography, X-Ray Computed, Osteoporosis. Die Arbeit nennt 42 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Beijing Municipality, Beijing New Health Industry Development Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To investigate the feasibility and accuracy of 100 kV low-voltage quantitative CT (QCT) for bone mineral density (BMD) measurement using the European Spine Phantom and patients. The accuracy and precision of the BMD measurements were assessed using relative measurement error (RME%), coefficient of variation (CV%), root mean square standard deviation (RMS-SD), and root mean square CV (RMS-%CV). Linear regression and Bland‒Altman analyses were used to assess the agreement between 100 and 120 kV QCT-based BMD measurements. The diagnostic performance of 100 kV QCT for osteoporosis was evaluated using receiver operating characteristic curve analysis. For the ESP, the mean BMD values at 100 kV were slightly greater than those at 120 kV, mainly due to small inaccuracies remaining in the BMD calibration process. The RME% values for all vertebrae were -3.31 to 15.00% at 100 kV and -9.34 to 3.06% at 120 kV, falling within ± 10% at 120 kV but within 0‒15% at 100 kV. The CV% and RMS-%CV values decreased as the BMD increased with increasing tube voltage, while the RMS-SD exhibited a decreasing trend. For patients, linear regression and Bland‒Altman analyses revealed good agreement between 120 and 100 kV (R2 = 0.987, P < 0.001; mean error, -3.39 mg/cm3; 95% limits of agreement, -16.49 to 9.71 mg/cm3). The 100 kV QCT achieved high accuracy in diagnosing osteoporosis (AUC = 0.992, P < 0.001), with a sensitivity of 99.04% and a specificity of 94.28%. 100 kV low-voltage QCT demonstrated acceptable accuracy and good reproducibility for measuring BMD, opening the possibility of 100 kV low-voltage chest CT obtained for lung cancer screening for opportunistic osteoporosis screening.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Bone DensityTomography, X-Ray ComputedOsteoporosisHumansPhantoms, ImagingFemaleFeasibility StudiesMaleAgedMiddle AgedAged, 80 and overReproducibility of ResultsAdultSpine

Stichwörter der Autor:innen

Bone mineral densityEuropean spine phantomLow-voltageQuantitative computed tomographyRadiation dose

Autor:innen und Institutionen

  • Department of Radiology, Peking University Third Hospital, 49 Huayuan N Rd, Haidian, Beijing, 100191, China.
  • The Institute of Intelligent Diagnostics, Beijing United-Imaging Research Institute of Intelligent Imaging, Building 3-4 F, 9 Yongteng N. Road, Beijing, 100080, China.
  • Department of Radiology, Peking University Third Hospital, 49 Huayuan N Rd, Haidian, Beijing, 100191, China. huishuy@bjmu.edu.cn.

ORCID-Profile: Yali Li

Förderung

  • National Natural Science Foundation of China
  • Natural Science Foundation of Beijing Municipality
  • Beijing New Health Industry Development Foundation

Zitieren

APA

Li, Y., Jin, D., Zhang, Y., Zhang, M., Qian, Z., Jiang, C., Ni, M., Liu, S., & Yuan, H. (2025). Feasibility of 100 kV Low-voltage Bone Mineral Density Measurement with Quantitative CT: Phantom and Clinical Research. Calcified Tissue International. https://doi.org/10.1007/s00223-025-01393-7

Vancouver

Li Y, Jin D, Zhang Y, Zhang M, Qian Z, Jiang C, et al. Feasibility of 100 kV Low-voltage Bone Mineral Density Measurement with Quantitative CT: Phantom and Clinical Research. Calcified Tissue International. 2025. doi:10.1007/s00223-025-01393-7

BibTeX
@article{Li2025,
  author = {Li, Yali and Jin, Dan and Zhang, Yan and Zhang, Mengze and Qian, Zhen and Jiang, Chenyu and Ni, Ming and Liu, Suwei and Yuan, Huishu},
  title = {Feasibility of 100 kV Low-voltage Bone Mineral Density Measurement with Quantitative CT: Phantom and Clinical Research},
  journal = {Calcified Tissue International},
  year = {2025},
  doi = {10.1007/s00223-025-01393-7}
}
Kostenlos starten →