EUVIMEDEUVIMED entdecken
Crossref

Dual agonist and antagonist muscle vibration produces a bias in end point with no change in variability

Gregg Eschelmuller, J Timothy Inglis, Hyosub Kim, Romeo Chua

Experimental Brain Research · 2025

DOI: 10.1007/s00221-025-07143-3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Experimental Brain Research, 2025. Verfasst von Gregg Eschelmuller und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Kinesiology, University of British Columbia, Vancouver, BC, Canada. gregg.eschelmuller@ubc.ca. Hauptthemen laut MEDLINE: Vibration, Muscle, Skeletal, Muscle Spindles, Feedback, Sensory. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 37 Literaturangaben. Gefördert von: Natural Sciences and Engineering Research Council of Canada.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Muscle spindles provide critical proprioceptive feedback about muscle length to the central nervous system (CNS). Single muscle tendon vibration can stimulate muscle spindles, causing illusory limb positions, while dual muscle tendon vibration is thought to produce a noisy proprioceptive system. It is currently unclear exactly how the CNS uses kinesthetic feedback from the agonist and antagonist muscles during target-directed reaches. The purpose of the current project was to investigate the effects of agonist, antagonist, and dual agonist/antagonist vibration during target-directed reaching. Using an elbow extension task, we found that antagonist muscle vibration produced an undershooting effect relative to the no-vibration control, while agonist muscle vibration produced an overshooting effect relative to the no-vibration control. Neither of the single muscle vibrations produced any change in the variable error of the movements. While it was originally hypothesized that dual agonist/antagonist vibration would increase participants' variable error with no change in bias, the opposite was found. Participants undershot relative to the no-vibration control with no change in variable error. Overall, the results from this study suggest that dual vibration does not necessarily create a noisy proprioceptive system but can produce a bias in end point.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

VibrationMuscle, SkeletalMuscle SpindlesFeedback, SensoryHumansMaleFemaleAdultProprioceptionPsychomotor PerformanceMovementElbow

Stichwörter der Autor:innen

KinesthesiaMotor controlMuscle spindleProprioceptionTendon vibration

Autor:innen und Institutionen

  • School of Kinesiology, University of British Columbia, Vancouver, BC, Canada. gregg.eschelmuller@ubc.ca.
  • School of Kinesiology, University of British Columbia, Vancouver, BC, Canada.
  • Graduate Program in Neuroscience, University of British Columbia, Vancouver, BC, Canada.

Förderung

  • Natural Sciences and Engineering Research Council of Canada

Zitieren

APA

Eschelmuller, G., Inglis, J. T., Kim, H., & Chua, R. (2025). Dual agonist and antagonist muscle vibration produces a bias in end point with no change in variability. Experimental Brain Research. https://doi.org/10.1007/s00221-025-07143-3

Vancouver

Eschelmuller G, Inglis JT, Kim H, Chua R. Dual agonist and antagonist muscle vibration produces a bias in end point with no change in variability. Experimental Brain Research. 2025. doi:10.1007/s00221-025-07143-3

BibTeX
@article{Eschelmuller2025,
  author = {Eschelmuller, Gregg and Inglis, J Timothy and Kim, Hyosub and Chua, Romeo},
  title = {Dual agonist and antagonist muscle vibration produces a bias in end point with no change in variability},
  journal = {Experimental Brain Research},
  year = {2025},
  doi = {10.1007/s00221-025-07143-3}
}
Kostenlos starten →