Employing a single trial motor equivalent analysis for the assessment of motor learning
Experimental Brain Research · 2025
DOI: 10.1007/s00221-025-07123-7 ↗Kurz gefasst
Fachartikel in der Zeitschrift Experimental Brain Research, 2025. Verfasst von Matthew Beerse und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Health and Sport Science, University of Dayton, 300 College Park, Dayton, OH, 45469-2968, USA. mbeerse1@udayton.edu. Hauptthemen laut MEDLINE: Learning, Psychomotor Performance, Motor Skills. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Dayton Research Council.
Abstract (Originalsprache)
The uncontrolled manifold analysis (UCM) is a useful technique for motor learning research enabling the classification of movement variability into solutions and errors. Less explored methodological considerations within the UCM framework are the selection of mean configurations outside of the current performance, as found in the Motor Equivalence Analysis, and a single trial approach. In this study, we demonstrated how calculating deviations away from varying mean configurations within the UCM influences the results and interpretations within motor learning experiments. Twelve young adult subjects (9F/3 M, 20.53 ± 1.25 years old) practiced the kettlebell swing over a one-week time period. We compared deviations from the mean configuration across all repetitions, to the mean of the first ten repetitions before practice and to the mean of their last ten repetitions after practice. Results suggested that subjects abandoned their initial mean performance within the first sets of kettlebell swings and reduced their errors and solutions towards what would become their mean performance after practice. They continued to refine their performance 1 week later. Subjects then completed a transfer task, testing their ability to adapt to a water-filled kettlebell. We evaluated deviations from their mean performance with the metal kettlebell and their mean performance with the water-filled kettlebell. Subjects did not reduce errors towards their mean metal kettlebell performance, but instead towards a new performance that matched the dynamics of the water-filled kettlebell. When performance is expected to change, i.e., motor learning, assessing how the variance structure changes with respect to different mean configurations can provide further insight when using a UCM approach.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Health and Sport Science, University of Dayton, 300 College Park, Dayton, OH, 45469-2968, USA. mbeerse1@udayton.edu.
- Department of Mechanical and Aerospace Engineering, University of Dayton, Dayton, OH, USA.
- Department of Physical Therapy, University of Dayton, Dayton, OH, USA.
ORCID-Profile: Matthew Beerse
Förderung
- University of Dayton Research Council
Zitieren
APA
Beerse, M., Bigelow, K. E., & Barrios, J. A. (2025). Employing a single trial motor equivalent analysis for the assessment of motor learning. Experimental Brain Research. https://doi.org/10.1007/s00221-025-07123-7
Vancouver
Beerse M, Bigelow KE, Barrios JA. Employing a single trial motor equivalent analysis for the assessment of motor learning. Experimental Brain Research. 2025. doi:10.1007/s00221-025-07123-7
BibTeX
@article{Beerse2025,
author = {Beerse, Matthew and Bigelow, Kimberly E and Barrios, Joaquin A},
title = {Employing a single trial motor equivalent analysis for the assessment of motor learning},
journal = {Experimental Brain Research},
year = {2025},
doi = {10.1007/s00221-025-07123-7}
}
EUVIMED