EUVIMEDEUVIMED entdecken
Crossref

Stripping voltammetric determination of zinc ions using a graphite-based electrochemical sensor modified with Alizarin Red S

Maqsud Sayfiyev, Qudrat Boqiyev, Makhsuda Nazarova, Dilshod Ziyaev, Utkirjon Madatov, Charos Komilova, Gulnoza Boshbekova, Jasur Tursunqulov, Shakhboz Khasanov

Analytical and Bioanalytical Chemistry · 2026-11 · 418 (22) · 7667-7679

DOI: 10.1007/s00216-026-06770-1 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, online erschienen am 03.09.2026. Verfasst von Maqsud Sayfiyev und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Analytical Chemistry, National University of Uzbekistan, Tashkent, 100174, Uzbekistan. Die Arbeit nennt 43 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A simple, low-cost, and sensitive electrochemical sensor was developed for the determination of zinc ions by anodic stripping voltammetry (ASV). The sensor (denoted G/W/ARS/MES) consists of a graphite-wax paste modified in situ with Alizarin Red S (ARS). The nature of the Zn-ARS interaction was examined by quantum-chemical calculations together with FT-IR and UV-Vis spectroscopy, which consistently indicated coordination of Zn(II) through the hydroxyl and carbonyl groups of ARS. Under optimised conditions-a universal buffer of pH 4.5-5.5, a 0.1 M H3PO4 + 0.1 M KNO3 supporting electrolyte and an 80 s accumulation time-the modified sensor produced a well-resolved Zn(II) stripping peak at - 1040 mV, shifted by about 280 mV from that of the unmodified electrode and clearly separated from the signals of Cd(II), Pb(II), and Cu(II). The peak current varied linearly with concentration over the range 2.0-35.0 µg L-1 (R2 = 0.9910), with a detection limit of 0.57 µg L-1. The method showed good repeatability and high selectivity and was applied to the determination of trace Zn(II) in waste, ground, and industrial-zone waters and in agricultural soils of the Jizzakh and Tashkent regions. The results agreed well with those obtained by atomic absorption spectrometry, confirming the accuracy of the proposed method.

Schlagwörter

Stichwörter der Autor:innen

Alizarin Red SAnodic stripping voltammetryChemically modified electrodeGraphite paste sensorWater and soil analysisZinc

Autor:innen und Institutionen

  • Department of Analytical Chemistry, National University of Uzbekistan, Tashkent, 100174, Uzbekistan.
  • Department of Medical and Biological Chemistry, Tashkent State Medical University, Tashkent, 100174, Uzbekistan.
  • Department of Pharmaceuticals and Chemistry, University of Alfraganus, Tashkent, 100190, Uzbekistan.
  • Department of Nuclear Physics and Astronomy, Institute of Nuclear Technologies, Samarkand State University Named After Sharof Rashidov, Samarkand, 1401014, Uzbekistan. shakhbozkhasanov93@gmail.com.

Zitieren

APA

Sayfiyev, M., Boqiyev, Q., Nazarova, M., Ziyaev, D., Madatov, U., Komilova, C., Boshbekova, G., Tursunqulov, J., & Khasanov, S. (2026). Stripping voltammetric determination of zinc ions using a graphite-based electrochemical sensor modified with Alizarin Red S. Analytical and Bioanalytical Chemistry, 418(22), 7667-7679. https://doi.org/10.1007/s00216-026-06770-1

Vancouver

Sayfiyev M, Boqiyev Q, Nazarova M, Ziyaev D, Madatov U, Komilova C, et al. Stripping voltammetric determination of zinc ions using a graphite-based electrochemical sensor modified with Alizarin Red S. Analytical and Bioanalytical Chemistry. 2026;418(22):7667-7679. doi:10.1007/s00216-026-06770-1

BibTeX
@article{Sayfiyev2026,
  author = {Sayfiyev, Maqsud and Boqiyev, Qudrat and Nazarova, Makhsuda and Ziyaev, Dilshod and Madatov, Utkirjon and Komilova, Charos and Boshbekova, Gulnoza and Tursunqulov, Jasur and Khasanov, Shakhboz},
  title = {Stripping voltammetric determination of zinc ions using a graphite-based electrochemical sensor modified with Alizarin Red S},
  journal = {Analytical and Bioanalytical Chemistry},
  year = {2026},
  volume = {418},
  number = {22},
  pages = {7667--7679},
  doi = {10.1007/s00216-026-06770-1}
}