Determination of the optimal injection parameters for the SPME Arrow analysis of VOCs
Analytical and Bioanalytical Chemistry · 2026-11 · 418 (22) · 7567-7578
DOI: 10.1007/s00216-026-06757-y ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, online erschienen am 31.08.2026. Verfasst von Nenad Stojanović und 2 weiteren Autor:innen. Beteiligte Einrichtung: Instrumental Analytical Chemistry, University of Duisburg-Essen, Universitätsstrasse 5, 45141, Essen, Germany. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union's Horizon 2020, European Union’s Horizon 2020, Universität Duisburg-Essen.
Abstract (Originalsprache)
The injection step in SPME Arrow-GC-MS analysis is critical for sensitivity, repeatability, and peak shape, but is often less systematically optimized than extraction. In this study, the injection efficiency of SPME Arrow fibers was investigated using 1-methylnaphthalene as a model volatile organic compound. Real-time desorption-and-transfer profiles were recorded to evaluate the effects of liner geometry, carrier-gas flow rate, and column insertion depth for two coatings, PDMS/CWR and PDMS/DVB. Here, desorption denotes analyte release from the coating, while transfer denotes the subsequent transport of the released analyte through the injector and into the column or detector connection. Total peak area was used as a measure of transferred analyte amount, while the half-mass point described transfer kinetics. The results show that SPME Arrow injection is governed by a combined desorption-and-transfer process rather than by thermal desorption alone. For PDMS/CWR, a narrow 1.2 mm i.d. liner markedly improved injection efficiency compared with a conventional 2.0 mm i.d. liner, providing relative desorption-and-transfer response close to 100% over a broad range of carrier-gas flow rates. The narrow liner also reduced half-mass points, indicating faster transfer. For PDMS/DVB, however, the highest total peak areas were obtained with the wider liner at elevated carrier-gas flow rates, although the narrow liner produced faster transfer. These results demonstrate that optimal injection conditions are strongly coating-dependent and cannot be predicted solely from liner diameter or carrier-gas velocity. The study highlights the need to optimize SPME Arrow injection parameters separately for each coating and analytical objective. Both total transferred amount and transfer kinetics should be considered, since the fastest transfer condition does not necessarily provide the highest analyte recovery.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Instrumental Analytical Chemistry, University of Duisburg-Essen, Universitätsstrasse 5, 45141, Essen, Germany.
- Instrumental Analytical Chemistry, University of Duisburg-Essen, Universitätsstrasse 5, 45141, Essen, Germany. maik.jochmann@uni-due.de.
- Centre for Water and Environmental Research, University of Duisburg-Essen, Universitätsstrasse 5, 45141, Essen, Germany.
- IWW Water Centre, Moritzstrasse 26, 45476, Mülheim an der Ruhr, Germany.
Förderung
- European Union's Horizon 2020
- European Union’s Horizon 2020
- Universität Duisburg-Essen
Zitieren
APA
Stojanović, N., Jochmann, M. A., & Schmidt, T. C. (2026). Determination of the optimal injection parameters for the SPME Arrow analysis of VOCs. Analytical and Bioanalytical Chemistry, 418(22), 7567-7578. https://doi.org/10.1007/s00216-026-06757-y
Vancouver
Stojanović N, Jochmann MA, Schmidt TC. Determination of the optimal injection parameters for the SPME Arrow analysis of VOCs. Analytical and Bioanalytical Chemistry. 2026;418(22):7567-7578. doi:10.1007/s00216-026-06757-y
BibTeX
@article{Stojanovi2026,
author = {Stojanović, Nenad and Jochmann, Maik A and Schmidt, Torsten C},
title = {Determination of the optimal injection parameters for the SPME Arrow analysis of VOCs},
journal = {Analytical and Bioanalytical Chemistry},
year = {2026},
volume = {418},
number = {22},
pages = {7567--7578},
doi = {10.1007/s00216-026-06757-y}
}
EUVIMED