EUVIMEDEUVIMED entdecken
Crossref

Synthesis of hydroxyl-rich covalent organic framework–coated stainless steel fiber for efficient solid-phase microextraction of psychiatric drugs from water and milk samples

Zhi Hu, Jinna Xiao, Lianqi Hu, Haijiao Xie, Zhengzheng Liao, Zhentao Li

Analytical and Bioanalytical Chemistry · 2026-11 · 418 (22) · 7421-7433

DOI: 10.1007/s00216-026-06736-3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, online erschienen am 10.08.2026. Verfasst von Zhi Hu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmacy, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, 330006, Jiangxi, People's Republic of …. Hauptthemen laut MEDLINE: Solid Phase Microextraction, Milk, Stainless Steel, Water Pollutants, Chemical. Die Arbeit nennt 41 Literaturangaben. Gefördert von: The National Natural Science Foundation of China, The Foundation of the Jiangxi Provincial Department of Science and Technology Youth Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The increasing misuse of psychiatric drugs has led to their emergence as environmental contaminants in water and food matrices, raising public health concerns. In this study, a hydroxyl-rich covalent organic framework (Py-DHBD-COF) was solvothermally synthesized and coated onto a stainless steel fiber for use in direct-immersion solid-phase microextraction (DI-SPME). The fabricated fiber was employed to extract psychiatric drugs from environmental water and pretreated milk extracts, followed by analysis using high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). The hydroxyl-rich structure of the Py-DHBD-COF coating can provide hydrogen-bonding, hydrophobic interactions, and π-π interactions with the target analytes, resulting in high extraction efficiency. Key parameters affecting extraction performance, including extraction time, volume, pH, and desorption conditions, were systematically optimized. Under optimal conditions, the method exhibited good linearity (R2 = 0.9992-0.9996) for quetiapine, olanzapine, and clozapine over a concentration range of 1-500 ng/mL, with low limits of detection (0.010-0.024 ng/mL). The reproducibility was satisfactory, showing relative standard deviations below 5.38%, and recoveries ranged from 85.1 to 114.6% in both sample matrices. These results demonstrate that the proposed SPME-HPLC-MS/MS method is a sensitive, reliable, and environmentally friendly approach for monitoring trace levels of psychiatric drugs in complex water and milk samples.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Solid Phase MicroextractionMilkStainless SteelWater Pollutants, ChemicalPsychotropic DrugsAnimalsChromatography, High Pressure LiquidLimit of DetectionFood ContaminationTandem Mass SpectrometryHydroxides

Stichwörter der Autor:innen

Covalent organic frameworkMilk samplesPsychiatric drugsSolid-phase microextractionWater samples

Substanzen

Stainless SteelWater Pollutants, ChemicalPsychotropic DrugsHydroxides

Autor:innen und Institutionen

  • Department of Pharmacy, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, 330006, Jiangxi, People's Republic of China.
  • Hangzhou Yanqu Information Technology Co., Ltd., Y2, 2nd Floor, Building 2, Xixi Legu Creative Pioneering Park, No. 712 Wen'er West Road, Xihu District, Hangzhou, 310003, Zhejiang, People's Republic of China.
  • Department of Pharmacy, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, 330006, Jiangxi, People's Republic of China. liaozhengzheng@ncu.edu.cn.
  • Department of Pharmacy, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, 330006, Jiangxi, People's Republic of China. 1046237778@qq.com.

Förderung

  • The National Natural Science Foundation of China
  • The Foundation of the Jiangxi Provincial Department of Science and Technology Youth Project

Zitieren

APA

Hu, Z., Xiao, J., Hu, L., Xie, H., Liao, Z., & Li, Z. (2026). Synthesis of hydroxyl-rich covalent organic framework–coated stainless steel fiber for efficient solid-phase microextraction of psychiatric drugs from water and milk samples. Analytical and Bioanalytical Chemistry, 418(22), 7421-7433. https://doi.org/10.1007/s00216-026-06736-3

Vancouver

Hu Z, Xiao J, Hu L, Xie H, Liao Z, Li Z. Synthesis of hydroxyl-rich covalent organic framework–coated stainless steel fiber for efficient solid-phase microextraction of psychiatric drugs from water and milk samples. Analytical and Bioanalytical Chemistry. 2026;418(22):7421-7433. doi:10.1007/s00216-026-06736-3

BibTeX
@article{Hu2026,
  author = {Hu, Zhi and Xiao, Jinna and Hu, Lianqi and Xie, Haijiao and Liao, Zhengzheng and Li, Zhentao},
  title = {Synthesis of hydroxyl-rich covalent organic framework–coated stainless steel fiber for efficient solid-phase microextraction of psychiatric drugs from water and milk samples},
  journal = {Analytical and Bioanalytical Chemistry},
  year = {2026},
  volume = {418},
  number = {22},
  pages = {7421--7433},
  doi = {10.1007/s00216-026-06736-3}
}
Kostenlos starten →