Ultrasensitive miRNA-21 biosensing: a metal-free photoinduced ROMP strategy via 3′-end oxidation
Analytical and Bioanalytical Chemistry · 2026-11 · 418 (22) · 7381-7394
DOI: 10.1007/s00216-026-06733-6 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, online erschienen am 15.08.2026. Verfasst von Yunna Li und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Environmental and Biological Engineering, Nanjing University of Science and Technology, Nanjing, 210094, Jiangsu, China. Hauptthemen laut MEDLINE: MicroRNAs, Biosensing Techniques, Electrochemical Techniques. Die Arbeit nennt 44 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
MicroRNA-21 (miRNA-21) is frequently overexpressed in various solid tumors, making its reliable quantification important for cancer-related biomarker analysis. Herein, we report an electrochemical sensing strategy that integrates RNA 3'-end oxidation with metal-free photo-induced ring-opening metathesis polymerization (photo-ROMP) for miRNA-21 detection. After hybridization with a thiolated DNA probe immobilized on a gold electrode, the 3'-terminal cis-diol group of miRNA-21 was selectively oxidized by sodium periodate to generate reactive aldehyde groups. The vinyl ether initiator 3-aminopropanol vinyl ether (APVE) was subsequently anchored to the oxidized miRNA-21 through aldehyde-amine condensation followed by NaCNBH3-mediated reductive amination. Under blue-light irradiation, photoexcited 2,4,6-tris(4-methoxyphenyl)pyrylium tetrafluoroborate (MeO-TPT) activated the interfacial APVE and initiated photo-ROMP of the cyclopentadienyl ferrocene (CFc), producing electroactive polymer chains on the electrode surface and amplifying the square-wave voltammetric response. Under optimized conditions, the biosensor exhibited a linear response toward miRNA-21 from 100 aM to 100 pM, with a calculated limit of detection of 28.48 aM. The sensor also showed good sequence selectivity, reproducibility, and short-term stability. Matrix-matched calibration in 10% diluted human serum yielded recoveries of 106.2-114.5% with relative standard deviations of 2.37-4.99%. These results demonstrate that target-end-triggered photo-ROMP provides an effective enzyme-free polymer amplification strategy for electrochemical miRNA detection in buffer and diluted serum matrices.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Environmental and Biological Engineering, Nanjing University of Science and Technology, Nanjing, 210094, Jiangsu, China.
- Department of Pathology, Nanjing First Hospital, Nanjing Medical University, Nanjing, 210006, Jiangsu, China. tianzhidan@foxmail.com.
- School of Environmental and Biological Engineering, Nanjing University of Science and Technology, Nanjing, 210094, Jiangsu, China. j.kong@njust.edu.cn.
- School of Biomedical Engineering, Shenzhen University Health Science Center, Shenzhen, 518060, China.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Li, Y., Zhou, S., Tian, Z., Kong, J., & Zhang, X. (2026). Ultrasensitive miRNA-21 biosensing: a metal-free photoinduced ROMP strategy via 3′-end oxidation. Analytical and Bioanalytical Chemistry, 418(22), 7381-7394. https://doi.org/10.1007/s00216-026-06733-6
Vancouver
Li Y, Zhou S, Tian Z, Kong J, Zhang X. Ultrasensitive miRNA-21 biosensing: a metal-free photoinduced ROMP strategy via 3′-end oxidation. Analytical and Bioanalytical Chemistry. 2026;418(22):7381-7394. doi:10.1007/s00216-026-06733-6
BibTeX
@article{Li2026,
author = {Li, Yunna and Zhou, Shijin and Tian, Zhidan and Kong, Jinming and Zhang, Xueji},
title = {Ultrasensitive miRNA-21 biosensing: a metal-free photoinduced ROMP strategy via 3′-end oxidation},
journal = {Analytical and Bioanalytical Chemistry},
year = {2026},
volume = {418},
number = {22},
pages = {7381--7394},
doi = {10.1007/s00216-026-06733-6}
}
EUVIMED