Parallel fluorescence interrogation of multichannel chips for rapid point-of-care testing
Analytical and Bioanalytical Chemistry · 2026-12 · 418 (23) · 7937-7951
DOI: 10.1007/s00216-026-06719-4 ↗Kurz gefasst
Evaluationsstudie in der Zeitschrift Analytical and Bioanalytical Chemistry, online erschienen am 08.08.2026. Verfasst von Cosimo Trono und 12 weiteren Autor:innen. Beteiligte Einrichtung: Istituto di Fisica Applicata "Nello Carrara", Consiglio Nazionale delle Ricerche, Via Madonna del Piano 10, 50019, Sesto Fiorentino, Italy. Hauptthemen laut MEDLINE: Microfluidic Analytical Techniques, Point-of-Care Testing, C-Reactive Protein, Lab-On-A-Chip Devices. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Consiglio Nazionale Delle Ricerche.
Abstract (Originalsprache)
The development of rapid and reliable point-of-care testing (POCT) devices requires optical platforms capable of combining fast readout, sensitivity, and robustness. In this work, a fully integrated optoelectronic platform for fluorescence detection in multichannel microfluidic chips is presented, based on a parallel optical interrogation strategy. The platform employs a diffractive optical element (DOE) to achieve simultaneous excitation of multiple microchannels and an array of waveguide absorption filters (WAFs) for parallel fluorescence collection and efficient rejection of excitation light. This configuration eliminates mechanical scanning and enables optical interrogation within a few seconds. The platform is integrated with a microfluidic handling system and dedicated control software, allowing automated execution of immunoassays. Stability and reproducibility were demonstrated through repeated chip loading experiments, showing low variability across microchannels. As a proof of concept, a fluorescence sandwich immunoassay for C-reactive protein (CRP) was implemented in plasma, achieving a limit of detection of 0.32 µg mL⁻1 with good intra- and inter-chip reproducibility. The proposed approach demonstrates the potential of parallel optical architectures for the development of rapid, scalable, and reliable fluorescence-based POCT platforms.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Istituto di Fisica Applicata "Nello Carrara", Consiglio Nazionale delle Ricerche, Via Madonna del Piano 10, 50019, Sesto Fiorentino, Italy.
- Datamed Srl, Via Amerigo Vespucci, 2/4/6, Peschiera Borromeo, Milan, Italy.
- Istituto per il Rilevamento Elettromagnetico dell'Ambiente, Consiglio Nazionale delle Ricerche, Via Diocleziano, 328, 80124, Naples, Italy.
- Istituto di Fisica Applicata "Nello Carrara", Consiglio Nazionale delle Ricerche, Via Madonna del Piano 10, 50019, Sesto Fiorentino, Italy. francesco.baldini@cnr.it.
Förderung
- Consiglio Nazionale Delle Ricerche
Zitieren
APA
Trono, C., Berneschi, S., Tombelli, S., Giannetti, A., Adinolfi, B., Chiavaioli, F., Porro, G., Bolzoni, L., Quarto, G., Bernini, R., Persichetti, G., Testa, G., & Baldini, F. (2026). Parallel fluorescence interrogation of multichannel chips for rapid point-of-care testing. Analytical and Bioanalytical Chemistry, 418(23), 7937-7951. https://doi.org/10.1007/s00216-026-06719-4
Vancouver
Trono C, Berneschi S, Tombelli S, Giannetti A, Adinolfi B, Chiavaioli F, et al. Parallel fluorescence interrogation of multichannel chips for rapid point-of-care testing. Analytical and Bioanalytical Chemistry. 2026;418(23):7937-7951. doi:10.1007/s00216-026-06719-4
BibTeX
@article{Trono2026,
author = {Trono, Cosimo and Berneschi, Simone and Tombelli, Sara and Giannetti, Ambra and Adinolfi, Barbara and Chiavaioli, Francesco and Porro, Giampiero and Bolzoni, Luca and Quarto, Giovanna and Bernini, Romeo and Persichetti, Gianluca and Testa, Genni and Baldini, Francesco},
title = {Parallel fluorescence interrogation of multichannel chips for rapid point-of-care testing},
journal = {Analytical and Bioanalytical Chemistry},
year = {2026},
volume = {418},
number = {23},
pages = {7937--7951},
doi = {10.1007/s00216-026-06719-4}
}