Tandem column coupling in supercritical fluid chromatography-mass spectrometry for the multiresidue analysis of pesticides in complex Allium vegetables
Analytical and Bioanalytical Chemistry · 2026-10 · 418 (19) · 6381-6390
DOI: 10.1007/s00216-026-06662-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, online erschienen am 10.07.2026. Verfasst von Víctor Cutillas und 3 weiteren Autor:innen. Beteiligte Einrichtung: European Union Reference Laboratory for Pesticide Residues in Fruit & Vegetables, Department of Chemistry and Physics, Research Centre for Mediterran…. Hauptthemen laut MEDLINE: Chromatography, Supercritical Fluid, Tandem Mass Spectrometry, Pesticide Residues, Vegetables. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: European Union.
Abstract (Originalsprache)
Supercritical fluid chromatography coupled with tandem mass spectrometry (SFC-MS/MS) has established itself as a powerful, environmentally sustainable alternative to conventional liquid chromatography for the multiresidue analysis of pesticides in food matrices. While single-column SFC-MS/MS configurations based on C18 stationary phases have demonstrated clear analytical advantages, their performance can be severely compromised in difficult matrices such as Allium vegetables, where dense co-extractive backgrounds cause significant ion suppression and limit method sensitivity. The serial coupling of columns with complementary selectivities is an inherently SFC-compatible strategy to improve chromatographic resolution without the pressure constraints that restrict analogous approaches in liquid chromatography. In this study, two tandem column configurations were evaluated for the SFC-MS/MS determination of 216 pesticides in onion, leek, and garlic: a 15 cm Silica column coupled upstream to a 25 cm C18 column, and a 15 cm Fluorophenyl column coupled to the same C18 column. Method performance was assessed by comparing limits of quantification (LOQ), matrix effects (ME), and reproducibility (RSD) against a reference single-C18 configuration across the three matrices. The assessment of method performance revealed that both tandem configurations effectively mitigated matrix effects relative to the single C18 setup, though with distinct trade-offs. The Fluorophenyl + C18 coupling provided a meaningful reduction in signal suppression across all matrices but this came at the cost of deteriorated reproducibility and a compound-dependent effect on sensitivity (in garlic it improved the LOQ of 27 compounds while worsening 23). Conversely, the Silica + C18 configuration proved to be the most balanced and robust strategy. It dramatically improved matrix effect mitigation (up to 78.7% of compounds showing negligible effects in onion), lowered LOQs for 38 compounds in garlic, and successfully preserved method precision by reducing the fraction of compounds with highly variable RSDs (> 20%) from 7.4% to just 1.4% in garlic. Finally, this Silica + C18 configuration was utilized for the analysis of real vegetable samples.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- European Union Reference Laboratory for Pesticide Residues in Fruit & Vegetables, Department of Chemistry and Physics, Research Centre for Mediterranean Intensive Agrosystems and Agri-Food Biotechnology (CIAMBITAL), Uni…
Förderung
- European Union
Zitieren
APA
Cutillas, V., Cano, A., Martínez-Bueno, M. J., & Fernández-Alba, A. R. (2026). Tandem column coupling in supercritical fluid chromatography-mass spectrometry for the multiresidue analysis of pesticides in complex Allium vegetables. Analytical and Bioanalytical Chemistry, 418(19), 6381-6390. https://doi.org/10.1007/s00216-026-06662-4
Vancouver
Cutillas V, Cano A, Martínez-Bueno MJ, Fernández-Alba AR. Tandem column coupling in supercritical fluid chromatography-mass spectrometry for the multiresidue analysis of pesticides in complex Allium vegetables. Analytical and Bioanalytical Chemistry. 2026;418(19):6381-6390. doi:10.1007/s00216-026-06662-4
BibTeX
@article{Cutillas2026,
author = {Cutillas, Víctor and Cano, Alba and Martínez-Bueno, María Jesús and Fernández-Alba, Amadeo R},
title = {Tandem column coupling in supercritical fluid chromatography-mass spectrometry for the multiresidue analysis of pesticides in complex Allium vegetables},
journal = {Analytical and Bioanalytical Chemistry},
year = {2026},
volume = {418},
number = {19},
pages = {6381--6390},
doi = {10.1007/s00216-026-06662-4}
}
EUVIMED