EUVIMEDEUVIMED entdecken
Validierungsstudie

Establishment and application of a QuEChERS-based high-performance liquid chromatography–mass spectrometry method for the analysis of 56 per- and polyfluoroalkyl substances in human plasma

Yujing Chuai, Xiaotao Zhou, Yuting Zhang, Jing Zhang, Jiaqi Guo, Yu Wang, Qianru Zhou, Yu Xia, Chunying Luo, Li Yong, Xiaoli Zou

Analytical and Bioanalytical Chemistry · 2026

DOI: 10.1007/s00216-026-06486-2 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Analytical and Bioanalytical Chemistry, 2026. Verfasst von Yujing Chuai und 10 weiteren Autor:innen. Beteiligte Einrichtung: West China School of Public Health and West China Fourth Hospital, Health Promotion and Food Nutrition & Safety Key Laboratory of Sichuan Province, S…. Hauptthemen laut MEDLINE: Fluorocarbons, Tandem Mass Spectrometry, Liquid Chromatography-Mass Spectrometry, Environmental Pollutants. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 56 Literaturangaben. Gefördert von: the Graduate High-level Talent Training Program of Xizang University, The Key Open Project of Chongqing Academy of Preventive Medicine.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Per- and polyfluoroalkyl substances (PFAS) have attracted increasing concern due to their environmental persistence and potential adverse health effects. In this study, a high-performance liquid chromatography-tandem mass spectrometry method was developed for the simultaneous determination of 56 PFASs in human plasma. After the plasma sample was extracted with methanol, 5 mg primary secondary amine (PSA), 20 mg graphitized carbon black (GCB), and 30 mg C18 were added for QuEChERS purification, followed by nitrogen drying and reconstitution. The chromatographic separation was performed on a C18 column with a gradient elution and was quantified on mass spectrometry with electrospray ionization in negative mode. The method was validated and good linearity was obtained in the range of 0.050-50.0 ng/mL. The limits of detection were 0.0024 to 2.05 ng/mL, and except for a few perfluoroalkyl phosphinic acids and fluorinated polymer-based substances with low signal intensities, most PFASs showed satisfactory recoveries of 70-120%, with relative standard deviations below 12%. The validated method was applied to analyze plasma samples from pregnant women and males over 50 years old. The results revealed widespread PFAS contamination in the population, with perfluoroalkyl carboxylic acids as the dominant contributors, followed by perfluoroalkyl sulfonic acids and accompanied by a limited number of emerging PFAS alternatives. There are population-specific differences in PFAS exposure, with median concentrations typically higher in males aged over 50 years than in pregnant women, but 6:2 FTS is much higher in pregnant women. The established method is sensitive and efficient, and the results highlight the importance of population-stratified biomonitoring of PFASs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

FluorocarbonsTandem Mass SpectrometryLiquid Chromatography-Mass SpectrometryEnvironmental PollutantsHumansChromatography, High Pressure LiquidFemaleLimit of DetectionPregnancyReproducibility of Results

Stichwörter der Autor:innen

HPLC–MS/MSPFAS exposure biomonitoringPlasma analysisQuEChERS

Substanzen

FluorocarbonsEnvironmental Pollutants

Autor:innen und Institutionen

  • West China School of Public Health and West China Fourth Hospital, Health Promotion and Food Nutrition & Safety Key Laboratory of Sichuan Province, Sichuan University, Chengdu, 610041, Sichuan, China.
  • Chongqing Center for Disease Control and Prevention (Chongqing Academy of Preventive Medicine), Chongqing, 400707, China.
  • Suzhou Center for Disease Control and Prevention, Suzhou, 225000, Jiangsu, China. xiayusuzhou@hotmail.com.
  • Chengdu Center for Disease Control and Prevention (Chengdu Institute of Health Supervision), Sichuan, 610041, China. cyluo2012@163.com.
  • Sichuan Center for Disease Control and Prevention, Chengdu, 610041, Sichuan, China. 79145020@qq.com.
  • West China School of Public Health and West China Fourth Hospital, Health Promotion and Food Nutrition & Safety Key Laboratory of Sichuan Province, Sichuan University, Chengdu, 610041, Sichuan, China. zouxl_1113@163.com.

Förderung

  • the Graduate High-level Talent Training Program of Xizang University
  • The Key Open Project of Chongqing Academy of Preventive Medicine

Zitieren

APA

Chuai, Y., Zhou, X., Zhang, Y., Zhang, J., Guo, J., Wang, Y., Zhou, Q., Xia, Y., Luo, C., Yong, L., & Zou, X. (2026). Establishment and application of a QuEChERS-based high-performance liquid chromatography–mass spectrometry method for the analysis of 56 per- and polyfluoroalkyl substances in human plasma. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-026-06486-2

Vancouver

Chuai Y, Zhou X, Zhang Y, Zhang J, Guo J, Wang Y, et al. Establishment and application of a QuEChERS-based high-performance liquid chromatography–mass spectrometry method for the analysis of 56 per- and polyfluoroalkyl substances in human plasma. Analytical and Bioanalytical Chemistry. 2026. doi:10.1007/s00216-026-06486-2

BibTeX
@article{Chuai2026,
  author = {Chuai, Yujing and Zhou, Xiaotao and Zhang, Yuting and Zhang, Jing and Guo, Jiaqi and Wang, Yu and Zhou, Qianru and Xia, Yu and Luo, Chunying and Yong, Li and Zou, Xiaoli},
  title = {Establishment and application of a QuEChERS-based high-performance liquid chromatography–mass spectrometry method for the analysis of 56 per- and polyfluoroalkyl substances in human plasma},
  journal = {Analytical and Bioanalytical Chemistry},
  year = {2026},
  doi = {10.1007/s00216-026-06486-2}
}
Kostenlos starten →