EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Evaluation of isotope-dilution mass spectrometry, internal standard, and external standard methods for PFAS quantification in tap water and soil

Eriko Yamazaki, Nobuyasu Hanari, Keisuke Nakamura

Analytical and Bioanalytical Chemistry · 2026-06 · 418 (11) · 3387-3396

DOI: 10.1007/s00216-026-06447-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, online erschienen am 20.03.2026. Verfasst von Eriko Yamazaki und 2 weiteren Autor:innen. Beteiligte Einrichtung: Research Institute for Material and Chemical Measurement, National Metrology Institute of Japan, National Institute of Advanced Industrial Science an…. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Japan Society for the Promotion of Science, National Institute of Advanced Industrial Science and Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate quantification of per- and polyfluoroalkyl substances (PFAS) in environmental matrices is crucial for reliable exposure assessment but remains challenging owing to low concentrations and matrix-induced variability. In this study, three calibration approaches, external standard (ES), internal standard (IS), and isotope dilution mass spectrometry (IDMS), were systematically evaluated for the determination of perfluorohexanesulfonic acid (PFHxS), perfluorooctanesulfonic acid (PFOS), perfluorooctanoic acid (PFOA), and perfluorononanoic acid (PFNA) in fortified tap water and fortified soil. Linearity of calibration curves was assessed across five concentration levels for each analyte. IDMS consistently demonstrated the highest linearity (coefficient of determination R2 of 0.999) for all target analytes, followed by IS. ES displayed acceptable linearity, although the performance was slightly lower in soil matrices, with R2 ranging from 0.992 to 0.996. Accuracy was evaluated using measured-to-assigned concentration ratios in spiked tap water. IDMS yielded ratios of 0.96-1.07 with small standard deviations, demonstrating high trueness. When IDMS was used as the reference, IS and ES showed matrix- and analyte-dependent biases. In tap water, IS improved agreement with IDMS relative to ES but still overestimated PFOS, PFOA, and PFNA, whereas ES showed the largest positive bias. In soil, IS produced values close to those of IDMS for all analytes, while ES exhibited greater variability and occasional underestimation. Overall, IDMS enabled the most consistent and reliable quantification across matrices. These results highlight the importance of isotope dilution calibration using structurally matched mass-labeled standards and indicate that IS and ES methods require careful consideration of matrix effects and surrogate selection.

Schlagwörter

Stichwörter der Autor:innen

External standard methodInternal standard methodIsotope dilution mass spectrometry (IDMS)Per- and polyfluoroalkyl substances (PFAS)SoilTap water

Autor:innen und Institutionen

  • Research Institute for Material and Chemical Measurement, National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology (NMIJ/AIST), 1-1-1 Umezono, Tsukuba, Ibaraki, 305-8563, J…

Förderung

  • Japan Society for the Promotion of Science
  • National Institute of Advanced Industrial Science and Technology

Zitieren

APA

Yamazaki, E., Hanari, N., & Nakamura, K. (2026). Evaluation of isotope-dilution mass spectrometry, internal standard, and external standard methods for PFAS quantification in tap water and soil. Analytical and Bioanalytical Chemistry, 418(11), 3387-3396. https://doi.org/10.1007/s00216-026-06447-9

Vancouver

Yamazaki E, Hanari N, Nakamura K. Evaluation of isotope-dilution mass spectrometry, internal standard, and external standard methods for PFAS quantification in tap water and soil. Analytical and Bioanalytical Chemistry. 2026;418(11):3387-3396. doi:10.1007/s00216-026-06447-9

BibTeX
@article{Yamazaki2026,
  author = {Yamazaki, Eriko and Hanari, Nobuyasu and Nakamura, Keisuke},
  title = {Evaluation of isotope-dilution mass spectrometry, internal standard, and external standard methods for PFAS quantification in tap water and soil},
  journal = {Analytical and Bioanalytical Chemistry},
  year = {2026},
  volume = {418},
  number = {11},
  pages = {3387--3396},
  doi = {10.1007/s00216-026-06447-9}
}