EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Accelerating microfluidic capillary electrophoresis-mass spectrometry for charge-variant and glycoform analysis of intact monoclonal antibodies

Ruben Cageling, Erin A Redman, J Scott Mellors, Karin Lubbers-Geuijen, Govert W Somsen, Kevin Jooß

Analytical and Bioanalytical Chemistry · 2026

DOI: 10.1007/s00216-026-06374-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, 2026. Verfasst von Ruben Cageling und 5 weiteren Autor:innen. Beteiligte Einrichtung: Protein Purification & Characterization Department, Polpharma Biologics Utrecht, Yalelaan 46, 3584 CM, Utrecht, The Netherlands. Hauptthemen laut MEDLINE: Antibodies, Monoclonal, Mass Spectrometry, Microfluidic Analytical Techniques. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The analytical determination of critical quality attributes (CQAs) of monoclonal antibodies (mAbs) is often time-consuming. Hence, increasing analysis throughput can shorten biopharmaceutical development timelines and enables rapid decision-making. Microfluidic capillary electrophoresis coupled to mass spectrometry (MCE-MS) allows fast analysis of charge variants and glycoforms of mAb samples. In a recently published MCE-MS method, we used a microfluidic chip with a 22-cm separation channel length, permitting analysis of 96 samples per day. To further increase the throughput of the method and better meet the needs of the biopharmaceutical industry, we propose the use of a chip with a distinctly shorter channel length (10 cm). However, a substantial drop in electrophoretic resolution was observed due to the increased laminar flow caused by the pressure put on the shortened channel during analysis. To mitigate this phenomenon, the MCE setup was modified to allow independent adjustment of the gas pressure on the separation channel inlet. The mAb charge-variant resolution significantly improved by reducing the inlet pressure from 2.0 to 0.75 psi. The performance of the modified setup was assessed by analysis of mAb samples from cell lines, mimicking a typical biosimilar clone screening. The original (22-cm channel, 2.0 psi on inlet) and modified (10-cm channel, 0.75 psi on inlet) setups yielded comparable separation profiles and number of MS-identified proteoforms across all clone mAbs. Overall, the new MCE-MS method reduces total analysis time per sample by 3.3-fold, which conceptually facilitates the analysis of more than 300 samples per day with minimal loss in separation performance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Antibodies, MonoclonalMass SpectrometryMicrofluidic Analytical TechniquesElectrophoresis, CapillaryGlycosylationAnimalsHumansCricetulusCHO CellsEquipment Design

Stichwörter der Autor:innen

Capillary zone electrophoresisCharge heterogeneityGlycoformsHigh throughputMicrofluidic chip

Substanzen

Antibodies, Monoclonal

Autor:innen und Institutionen

  • Protein Purification & Characterization Department, Polpharma Biologics Utrecht, Yalelaan 46, 3584 CM, Utrecht, The Netherlands.
  • Division of BioAnalytical Chemistry, Department of Chemistry and Pharmaceutical Sciences, Vrije Universiteit Amsterdam, de Boelelaan 1085, 1081 HV, Amsterdam, The Netherlands.
  • Centre for Analytical Sciences Amsterdam (CASA), Amsterdam, The Netherlands.
  • Repligen Corporation, Morrisville, NC, USA.
  • Move Analytical LLC, Carrboro, NC, USA.
  • Division of BioAnalytical Chemistry, Department of Chemistry and Pharmaceutical Sciences, Vrije Universiteit Amsterdam, de Boelelaan 1085, 1081 HV, Amsterdam, The Netherlands. k.jooss@vu.nl.

Zitieren

APA

Cageling, R., Redman, E. A., Mellors, J. S., Lubbers-Geuijen, K., Somsen, G. W., & Jooß, K. (2026). Accelerating microfluidic capillary electrophoresis-mass spectrometry for charge-variant and glycoform analysis of intact monoclonal antibodies. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-026-06374-9

Vancouver

Cageling R, Redman EA, Mellors JS, Lubbers-Geuijen K, Somsen GW, Jooß K. Accelerating microfluidic capillary electrophoresis-mass spectrometry for charge-variant and glycoform analysis of intact monoclonal antibodies. Analytical and Bioanalytical Chemistry. 2026. doi:10.1007/s00216-026-06374-9

BibTeX
@article{Cageling2026,
  author = {Cageling, Ruben and Redman, Erin A and Mellors, J Scott and Lubbers-Geuijen, Karin and Somsen, Govert W and Jooß, Kevin},
  title = {Accelerating microfluidic capillary electrophoresis-mass spectrometry for charge-variant and glycoform analysis of intact monoclonal antibodies},
  journal = {Analytical and Bioanalytical Chemistry},
  year = {2026},
  doi = {10.1007/s00216-026-06374-9}
}
Kostenlos starten →