EUVIMEDEUVIMED entdecken
Crossref

Autofluorescence-free ratiometric temperature monitoring with multiple emissive persistent luminescent nanothermometers

Lingling Qiu, Jiahui Tan, Jiayi Chen, Bing Qi, Ziyun Miao, Yurong Wei, Xuewen He, Jie Wang

Analytical and Bioanalytical Chemistry · 2026

DOI: 10.1007/s00216-026-06352-1 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, 2026. Verfasst von Lingling Qiu und 7 weiteren Autor:innen. Beteiligte Einrichtung: The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, …. Hauptthemen laut MEDLINE: Thermometers, Luminescent Measurements, Nanoparticles. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 69 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Luminescent thermometers have emerged as a powerful tool for monitoring physiological temperature variations that are critical to understanding biological processes and pathological conditions. However, measurement artifacts from instrumental fluctuations and spectral interference from tissue autofluorescence seriously decreased the accuracy and sensitivity of luminescent thermometers. To address these limitations, we developed Zn2GeO4:Bi,Tb (ZGO:Bi,Tb) nanoparticles that feature temperature-dependent ratiometric persistent luminescence through a bottom-up synthesis approach for the first time. ZGO:Bi,Tb exhibited temperature-dependent ratiometric persistent luminescence between 298 and 358 K. The self-calibration function of ZGO:Bi,Tb allowed the efficient elimination of interference from instrumental anomalies such as photomultiplier voltage fluctuations. Besides, ZGO:Bi,Tb efficiently avoided autofluorescence interference by collecting the ratiometric persistent luminescence after excitation ceases. The temperature quantified by the I545/I585 ratio of ZGO:Bi,Tb well matched the real temperature with a deviation down to 0.88%. Furthermore, we engineered a theranostic platform with a temperature feedback function by integrating ZGO:Bi,Tb with indocyanine green (ICG), achieving simultaneous photothermal therapy (PTT) and temperature detection. The ZGO:Bi,Tb-ICG platform not only effectively eradicated bacterial pathogens by its photothermal effect but also accurately monitored the temperature during PTT. The PTT temperature determined by the I545/I585 ratio of the ZGO:Bi,Tb-ICG platform well matched that measured by an infrared thermal camera with a correlation coefficient reaching 0.991. Our study establishes a paradigm for highly accurate and sensitive temperature monitoring and provides a promising tool for research on temperature-dependent physiological processes and pathological states of living organisms.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ThermometersLuminescent MeasurementsNanoparticlesTemperatureLuminescenceTerbiumHumans

Stichwörter der Autor:innen

AutofluorescenceBacteriaBiosensingNanothermometersPersistent luminescence

Substanzen

Terbium

Autor:innen und Institutionen

  • The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Suzhou, 215123, China.
  • School of Chemistry and Life Sciences, Suzhou University of Science and Technology, Suzhou, 215009, China. weiyurong@usts.edu.cn.
  • School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou, 225002, China. weiyurong@usts.edu.cn.
  • The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Suzhou, 215123, China. xheao@suda.edu.cn.
  • The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Suzhou, 215123, China. jiewang@suda.edu.cn.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Qiu, L., Tan, J., Chen, J., Qi, B., Miao, Z., Wei, Y., He, X., & Wang, J. (2026). Autofluorescence-free ratiometric temperature monitoring with multiple emissive persistent luminescent nanothermometers. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-026-06352-1

Vancouver

Qiu L, Tan J, Chen J, Qi B, Miao Z, Wei Y, et al. Autofluorescence-free ratiometric temperature monitoring with multiple emissive persistent luminescent nanothermometers. Analytical and Bioanalytical Chemistry. 2026. doi:10.1007/s00216-026-06352-1

BibTeX
@article{Qiu2026,
  author = {Qiu, Lingling and Tan, Jiahui and Chen, Jiayi and Qi, Bing and Miao, Ziyun and Wei, Yurong and He, Xuewen and Wang, Jie},
  title = {Autofluorescence-free ratiometric temperature monitoring with multiple emissive persistent luminescent nanothermometers},
  journal = {Analytical and Bioanalytical Chemistry},
  year = {2026},
  doi = {10.1007/s00216-026-06352-1}
}