EUVIMEDEUVIMED entdecken
Crossref

Capsule confined cascade reaction generating long-lasting and intensive chemiluminescence

Xueyun Lu, Xiaohe Huo, Yafei Tian, Dan Xiao, Cuisong Zhou

Analytical and Bioanalytical Chemistry · 2026-04 · 418 (8) · 2165-2173

DOI: 10.1007/s00216-026-06351-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, online erschienen am 30.01.2026. Verfasst von Xueyun Lu und 4 weiteren Autor:innen. Beteiligte Einrichtung: College of Chemistry, Sichuan University, Chengdu, 610064, P. R. China. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The development of feasible, low-cost, and long-persistent chemiluminescence (CL) systems is highly desirable for enhancing detection reproducibility and accuracy. Here, we present a space-confined CL system based on the LHC@G capsules, which are prepared via a one-pot ultrasound-assisted method to co-encapsulate glucose oxidase (GOx), hemin (a peroxidase mimic), and luminol within an oil-in-water structure. The LHC@G capsules are used for producing glow-type CL emission. Specifically, glucose is catalyzed by GOx on the capsule surface, yielding H2O2. The H2O2 then diffuses into the oil core and undergoes hemin-catalyzed in situ blue emission of luminol. The LHC@G capsule-based CL system exhibits intensive and prolonged blue emission for over 1500 s, with a nearly threefold enhancement in CL intensity compared to that of luminol solution. Mechanistic studies reveal that the excellent CL performance stems from a highly efficient cascade reaction and regulated diffusion. The proposed capsule CL system exhibits excellent reproducibility and storage stability, and has been successfully developed for simple, fast, and sensitive visual glucose detection with a LOD of 1.21 μM. This work provides a convenient strategy for constructing long-persistent and accurate CL systems in the field of point-of-care testing (POCT).

Schlagwörter

Stichwörter der Autor:innen

Cascade reactionLong-lasting chemiluminescenceOil-in-water capsulesRegulated diffusionVisual detection

Autor:innen und Institutionen

  • College of Chemistry, Sichuan University, Chengdu, 610064, P. R. China.
  • Institute of Physics, Henan Academy of Sciences, Zhengzhou, 450046, China.
  • College of Chemistry, Sichuan University, Chengdu, 610064, P. R. China. zcs@scu.edu.cn.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Lu, X., Huo, X., Tian, Y., Xiao, D., & Zhou, C. (2026). Capsule confined cascade reaction generating long-lasting and intensive chemiluminescence. Analytical and Bioanalytical Chemistry, 418(8), 2165-2173. https://doi.org/10.1007/s00216-026-06351-2

Vancouver

Lu X, Huo X, Tian Y, Xiao D, Zhou C. Capsule confined cascade reaction generating long-lasting and intensive chemiluminescence. Analytical and Bioanalytical Chemistry. 2026;418(8):2165-2173. doi:10.1007/s00216-026-06351-2

BibTeX
@article{Lu2026,
  author = {Lu, Xueyun and Huo, Xiaohe and Tian, Yafei and Xiao, Dan and Zhou, Cuisong},
  title = {Capsule confined cascade reaction generating long-lasting and intensive chemiluminescence},
  journal = {Analytical and Bioanalytical Chemistry},
  year = {2026},
  volume = {418},
  number = {8},
  pages = {2165--2173},
  doi = {10.1007/s00216-026-06351-2}
}
Kostenlos starten →