Tackling matrix effects in biosensor-based analysis of untreated blood plasma
Analytical and Bioanalytical Chemistry · 2026-12 · 418 (23) · 7839-7844
DOI: 10.1007/s00216-026-06312-9 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, online erschienen am 19.01.2026. Verfasst von Giusy Finocchiaro und 2 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Photonics and Electronics of the Czech Academy of Sciences, Chaberská 1014/57, 182 00, Prague, Czech Republic. Hauptthemen laut MEDLINE: Surface Plasmon Resonance, Biosensing Techniques, Carcinoembryonic Antigen, Plasma. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Institute for Cancer Research, Czech Science Foundation.
Abstract (Originalsprache)
Human blood plasma is the matrix of choice for clinical diagnostic applications. However, matrix effects associated with its complex composition interfere with the accurate detection of biomarkers that are often present at extremely low concentrations. This study investigates such matrix effects, particularly the nonspecific adsorption of blood plasma to the sensor surface and the interaction of endogenous antibodies with the used receptors, and shows how they can be discriminated using a surface plasmon resonance biosensor. Moreover, we describe a strategy to tackle matrix effects by combining sequential blood plasma/buffer injections, single-surface referencing, and the addition of an antibody against endogenous immunoglobulins to blood plasma. Finally, we apply this strategy to the detection of the cancer biomarker carcinoembryonic antigen in undiluted blood plasma, achieving detection limits of 12 ng/mL using direct detection, and 225 pg/mL using a sandwich assay with functional gold nanoparticles.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Institute of Photonics and Electronics of the Czech Academy of Sciences, Chaberská 1014/57, 182 00, Prague, Czech Republic.
- Institute of Photonics and Electronics of the Czech Academy of Sciences, Chaberská 1014/57, 182 00, Prague, Czech Republic. homola@ufe.cz.
Förderung
- National Institute for Cancer Research
- Czech Science Foundation
Zitieren
APA
Finocchiaro, G., Bocková, M., & Homola, J. (2026). Tackling matrix effects in biosensor-based analysis of untreated blood plasma. Analytical and Bioanalytical Chemistry, 418(23), 7839-7844. https://doi.org/10.1007/s00216-026-06312-9
Vancouver
Finocchiaro G, Bocková M, Homola J. Tackling matrix effects in biosensor-based analysis of untreated blood plasma. Analytical and Bioanalytical Chemistry. 2026;418(23):7839-7844. doi:10.1007/s00216-026-06312-9
BibTeX
@article{Finocchiaro2026,
author = {Finocchiaro, Giusy and Bocková, Markéta and Homola, Jiří},
title = {Tackling matrix effects in biosensor-based analysis of untreated blood plasma},
journal = {Analytical and Bioanalytical Chemistry},
year = {2026},
volume = {418},
number = {23},
pages = {7839--7844},
doi = {10.1007/s00216-026-06312-9}
}
EUVIMED