EUVIMEDEUVIMED entdecken
Evaluationsstudie

HiSorb-TD-GC–MS analysis of commercial CBD oils

Marios C Christodoulou, Efstathios A Elia, Agapios Agapiou

Analytical and Bioanalytical Chemistry · 2026

DOI: 10.1007/s00216-025-06304-1 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Analytical and Bioanalytical Chemistry, 2026. Verfasst von Marios C Christodoulou und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, University of Cyprus, P.O. Box 20537, 1678, Nicosia, Cyprus. Hauptthemen laut MEDLINE: Gas Chromatography-Mass Spectrometry, Plant Oils, Cannabidiol, Cannabis. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 51 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study presents the development of a HiSorb microextraction method coupled with thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS) for analyzing cannabidiol (CBD) in commercial hemp oils. Two HiSorb sorptive coatings were evaluated, triple-phase polydimethylsiloxane (PDMS)/carbon wide-range (CWR)/divinylbenzene (DVB) and double-phase PDMS/CWR, for their extraction efficiencies. The triple-phase HiSorb, combined with water-bath incubation for 2 h at 80 °C, delivered the highest CBD recovery. The developed HiSorb-TD-GC-MS method showed excellent linearity (R2 = 0.9951), with a method limit of detection (LOD) of 30 µg/mL and a limit of quantification (LOQ) of 100 µg/mL. The total chromatographic runtime was 11.2 min. Precision was satisfactory, with intra-day RSD % ranging from 6.8 to 7.3% and inter-day RSD % ranging from 6.5 to 7.7%. Recoveries at three concentration levels for diluted sample (low 100 μg/mL, medium 300 μg/mL, high 500 μg/mL) ranged from 77.2 to 86.4%. No detectable formation of Δ9-THC was observed, confirming that the method does not induce isomerization of CBD during GC analysis. Greenness assessment yielded AGREE = 0.75 (analytical method) and AGREEprep = 0.54 (sample preparation). The developed method was applied to commercial hemp oil samples and revealed no significant statistical difference (p > 0.05) between the label claim and measured CBD concentration in all tested samples. The application of green analytical methods contributes to sustainability by minimizing environmental impact and enhancing resource efficiency.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Gas Chromatography-Mass SpectrometryPlant OilsCannabidiolCannabisSolid Phase MicroextractionLimit of DetectionPlant Extracts

Stichwörter der Autor:innen

Cannabis oilsGC–MSGreen extractionSample preparationSorptive microextraction

Substanzen

Plant OilsCannabidiolhempseed oilPlant Extracts

Autor:innen und Institutionen

  • Department of Chemistry, University of Cyprus, P.O. Box 20537, 1678, Nicosia, Cyprus.
  • Department of Chemistry, University of Cyprus, P.O. Box 20537, 1678, Nicosia, Cyprus. elia.efstathios-andreas@ucy.ac.cy.
  • Department of Chemistry, University of Cyprus, P.O. Box 20537, 1678, Nicosia, Cyprus. agapiou.agapios@ucy.ac.cy.

Zitieren

APA

Christodoulou, M. C., Elia, E. A., & Agapiou, A. (2026). HiSorb-TD-GC–MS analysis of commercial CBD oils. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-025-06304-1

Vancouver

Christodoulou MC, Elia EA, Agapiou A. HiSorb-TD-GC–MS analysis of commercial CBD oils. Analytical and Bioanalytical Chemistry. 2026. doi:10.1007/s00216-025-06304-1

BibTeX
@article{Christodoulou2026,
  author = {Christodoulou, Marios C and Elia, Efstathios A and Agapiou, Agapios},
  title = {HiSorb-TD-GC–MS analysis of commercial CBD oils},
  journal = {Analytical and Bioanalytical Chemistry},
  year = {2026},
  doi = {10.1007/s00216-025-06304-1}
}
Kostenlos starten →